Automation Part SmartNexMSK Catalog

Teradyne LA768 950-601-02 Retrofit-Ready Logic Analyzer SE300

Teradyne LA768 950-601-02 retrofit-ready logic analyzer board for SE300 TLiIQ ATE systems. Drop-in replacement, compatibility verified, 12-month warranty.

SKULA768-950-601-02-949-769-00D-949-768-65-0040-18219-SE300
BrandTeradyne
SeriesOther series
Teradyne LA768-950-601-02-949-769-00D-949-768-65-0040-18219-SE300 ATE Logic Analyzer Board
Model context is attached to every quote action. Use WhatsApp for urgent downtime, or Email for purchasing records.
Model checkSKU and compatibility review Quality evidencePhotos and label notes when available Export supportPacking, courier, and delivery notes
Product Information

Model Details

SKU / Model LA768-950-601-02-949-769-00D-949-768-65-0040-18219-SE300
Brand Teradyne
Product Type ATE Logic Analyzer Board
Series Other series
Catalog Category Business & Industrial > Automation, Control & Flow Devices
Tags 950-601-02, ATE Retrofit, Automatic Test Equipment, Discontinued Part, LA768, Logic Analyzer, Replacement Board, SE300, Teradyne, TLiIQ
Catalog Paths

Continue from this exact model

Use the live catalog paths below to compare the same brand, product type, or series before sending your RFQ.

RFQ Intent Desk

Choose the right sourcing path for this model

Each action carries the product model and intent into the inquiry record so the sales follow-up starts with useful context.

Exact Model Quote

Use this path when the SKU, brand, quantity, and destination are already confirmed.

Start
Replacement Check

Use this path for old, obsolete, or uncertain models that need compatibility review.

Start
Quality Confirmation

Ask for label photos, packing notes, documentation, or pre-shipment checks.

Start
Urgent Dispatch

Route downtime or maintenance requests with target dispatch timing and courier country.

Start
Description

Teradyne LA768 950-601-02 Retrofit-Ready Logic Analyzer SE300 Overview

Teradyne LA768 950-601-02 Retrofit-Ready Logic Analyzer for SE300 Control Systems

The Teradyne LA768 950-601-02 (alternate part numbers: 949-769-00D, 949-768-65, 0040-18219) is a retrofit-ready logic analyzer board engineered for seamless integration into Teradyne SE300 and TLiIQ Automatic Test Equipment (ATE) platforms. As original Teradyne SE300 system components reach end-of-life and spare parts become increasingly scarce, the LA768 board provides a verified, drop-in replacement path that preserves existing test program sets (TPS), backplane connections, and system calibration data without requiring a full platform migration.

Industrial test engineers and ATE system integrators managing aging SE300 installations face a common challenge: sourcing discontinued logic analyzer boards that maintain full pin-electronic compatibility, preserve channel-to-channel timing accuracy, and support the existing TLiIQ software environment. The LA768 950-601-02 addresses this directly. Each unit is inspected, functionally tested, and shipped with a 12-month warranty, giving procurement teams and maintenance engineers the confidence to plan scheduled retrofits or respond to unplanned board failures without extended downtime.

Whether you are upgrading a single test cell or modernizing an entire ATE floor, the LA768 fits within the standard SE300 mainframe chassis alongside companion modules such as the Teradyne SE300 pin electronics card, SE300 timing generator board, and SE300 power supply module. Its backplane interface is fully compatible with the SE300 system bus, eliminating the need for custom adapter brackets or firmware patches during installation.

Upgrade Compatibility Table

Parameter Detail
Primary Part Number LA768 / 950-601-02
Alternate Part Numbers 949-769-00D, 949-768-65, 0040-18219
Compatible Platform Teradyne SE300, TLiIQ ATE System
Board Function Logic Analyzer / Digital Channel Acquisition
Backplane Interface SE300 Standard System Bus (direct slot replacement)
Installation Requirement No hardware modification required; slot-compatible
Communication Compatibility TLiIQ software environment; existing TPS preserved
Replacement Recommendation Direct drop-in for failed or end-of-life LA768 boards
Commissioning Notes Board address verification and channel calibration recommended post-installation
Warranty 12 months from date of shipment

Retrofit Planning for Existing Automation Systems

Successful integration of the LA768 950-601-02 into an active SE300 test system begins well before the board arrives on-site. Retrofit planning should account for the full scope of the test cell architecture. Engineers should verify that the SE300 mainframe chassis has an available slot in the correct position, and that the SE300 system power supply can sustain the additional load introduced by the replacement board. Power budget calculations are especially important in densely populated mainframes where multiple pin electronics cards, timing generator boards, and parametric measurement units (PMU) share a common backplane power rail.

Wiring and terminal adaptation should be reviewed against the original SE300 system schematic. The LA768 connects via the backplane edge connector; no external terminal wiring is required for the board itself, but any associated interface test adapter (ITA) or device interface board (DIB) connected to the test head must be verified for channel mapping consistency. If the system uses a Teradyne TLiIQ workstation controller running legacy test program sets, the software environment should be checked to confirm that the LA768 board address matches the slot assignment defined in the TPS configuration file. Mismatched board addresses are a common source of initialization errors during first power-on after a board swap.

For systems that also incorporate Teradyne SE300 analog measurement modules or SE300 functional test cards, the retrofit sequence should be planned to minimize disruption to adjacent slots. Removing and reseating neighboring boards during the LA768 installation can introduce connector wear; a careful extraction procedure using the correct board ejector tools is recommended. After physical installation, a full system self-test using the TLiIQ diagnostic suite should be executed before resuming production test operations.

Communication link integrity between the LA768 and the TLiIQ system controller should be confirmed via the built-in loopback diagnostic. If the SE300 system is networked to a factory automation layer or connected to an MES (Manufacturing Execution System) via GPIB or LAN, the network configuration should remain unchanged — the LA768 replacement does not alter the system’s external communication profile.

Downtime Control During System Migration

Minimizing test cell downtime during an LA768 board replacement requires a structured approach. The most effective strategy is to pre-stage the replacement board and complete all pre-installation checks — including visual inspection, part number verification, and a bench-level power-on test — before the production line is taken offline. This reduces the active maintenance window to the physical swap and post-installation verification steps only.

Original test program logic stored on the TLiIQ workstation is not affected by a board-level replacement, provided the new LA768 is installed in the same chassis slot and assigned the same board address. Engineers should back up the current TPS files and system configuration to a network share or removable media before beginning the swap, as a precautionary measure against unexpected software state changes during power cycling.

For facilities operating multiple SE300 systems, a rotational spare strategy — maintaining one pre-tested LA768 board in inventory — eliminates unplanned downtime entirely. When a board failure is detected, the spare is installed immediately while the failed unit is returned for evaluation or repair. This approach is particularly effective in high-volume semiconductor test environments where SE300 systems run continuous production shifts.

Post-installation, the recommended commissioning sequence is: (1) power-on system self-test, (2) TLiIQ board recognition check, (3) channel calibration run, (4) golden device correlation test using a known-good reference device, and (5) first-article production test with results compared against historical baseline data. Completing this sequence typically requires less than two hours, keeping the total maintenance window well within a standard planned maintenance interval.

Retrofit Support FAQ

Q1: Is the LA768 950-601-02 a direct replacement for all SE300 logic analyzer slot positions?
A: The LA768 950-601-02 is designed as a direct slot replacement for the original Teradyne LA768 board in SE300 mainframe systems. It is compatible with the standard SE300 backplane bus. If your system uses a non-standard slot configuration or a modified mainframe, please confirm the slot assignment and board address with your system documentation before installation.

Q2: Will my existing TLiIQ test programs run without modification after installing the LA768?
A: In standard configurations, existing TPS files do not require modification. The LA768 950-601-02 is recognized by the TLiIQ software environment using the same board address and resource identifiers as the original board. A post-installation calibration run is recommended to confirm channel timing accuracy before resuming production testing.

Q3: What pre-shipment testing is performed on each LA768 board?
A: Each LA768 950-601-02 unit undergoes functional power-on testing and visual inspection prior to shipment. Units are verified against known-good reference standards. All boards are shipped with a 12-month warranty covering functional defects. Detailed test records are available upon request for quality-critical procurement processes.

Q4: Can the LA768 be used in a TLiIQ system that has been partially upgraded with newer SE300 modules?
A: Yes. The LA768 950-601-02 is compatible with mixed-generation SE300 mainframes that include both original and upgraded modules, provided the backplane bus standard has not been changed. In systems where newer SE300 digital subsystem cards or upgraded timing generator modules have been installed alongside legacy boards, the LA768 operates independently within its assigned slot and does not interfere with adjacent module operation.


© 2026 SMARTNEXMSK. All rights reserved.
Original Source: https://smartnexmsk.com
Contact: sales@smartnexmsk.com | +86 18259474341

Request Quote WhatsApp Email