Siemens 6DP1308-8AA FUM308 Retrofit-Ready Ethernet Module for SIMATIC S5 Control Systems
The Siemens 6DP1308-8AA (FUM308) is a SINEC H1 Ethernet communication module designed for the SIMATIC S5 programmable logic controller platform. As legacy S5 systems approach end-of-life and original spare parts become increasingly scarce, the 6DP1308-8AA remains a critical component for engineers managing retrofit projects, control cabinet upgrades, and communication protocol migrations. This module enables SIMATIC S5 controllers — including the S5-115U, S5-135U, and S5-155U — to participate in SINEC H1 Ethernet networks, supporting peer-to-peer data exchange, supervisory SCADA connectivity, and distributed I/O communication across plant-floor environments.
Whether you are replacing a failed unit on an active production line, sourcing a tested spare for a scheduled maintenance window, or planning a phased migration from S5 to a modern SIMATIC S7 or S7-1500 architecture, the 6DP1308-8AA FUM308 provides the communication backbone your existing system depends on. Each unit is function-tested prior to shipment, supplied with a 12-month warranty, and available for fast global dispatch to minimize unplanned downtime.
Upgrade Compatibility Table
| Parameter | Details |
|---|---|
| SKU / Part Number | 6DP1308-8AA / FUM308 |
| Compatible Controllers | SIMATIC S5-115U, S5-135U, S5-155U |
| Network Protocol | SINEC H1 (IEEE 802.3 Ethernet) |
| Backplane Interface | S5 submodule slot (IM 308-C compatible rack) |
| Installation Requirement | Fits standard S5 central rack (CR) or expansion rack (ER); verify slot addressing |
| Communication Compatibility | SINEC H1 peer-to-peer, S5-compatible CP configuration via COM ET 200 |
| Replacement Recommendation | Direct replacement for failed or end-of-life FUM308 units; verify firmware revision |
| Commissioning Focus | Module address assignment, DB configuration, network parameter download via STEP 5 |
| Warranty | 12 months from date of shipment |
| Condition | Tested, function-verified prior to dispatch |
Retrofit Planning for Existing Automation Systems
Retrofitting a SIMATIC S5 system requires careful coordination across multiple hardware and software layers. The 6DP1308-8AA FUM308 occupies a dedicated submodule slot within the S5 central rack or expansion rack, and its physical installation must be followed by correct module address configuration in the STEP 5 project. Before removing the failed module, engineers should document the existing DB (data block) assignments and network parameters stored in the CPU — typically a CPU 944, CPU 945, or CPU 948 — to ensure the replacement unit is configured identically.
Power budget verification is essential: the S5 rack power supply unit (PSU), such as the 6ES5 955-3LC41 or equivalent, must have sufficient reserve capacity to support the FUM308 alongside other installed modules including digital input/output cards, analog I/O modules, and any IM 308-C interface modules used for ET 200 distributed I/O expansion. Overloaded rack power supplies are a common cause of intermittent communication faults that are misdiagnosed as module failures.
Terminal wiring for the SINEC H1 Ethernet connection uses standard RJ-45 or coaxial AUI interfaces depending on the network topology in use. Verify the existing cable plant — whether 10BASE-T twisted pair or 10BASE5 thick coax — matches the port configuration of the replacement FUM308. In mixed-media environments, an external SINEC H1 transceiver or media converter may be required to bridge legacy coax segments to modern structured cabling.
For systems where the S5 communicates upstream to a SIMATIC WinCC or SIMATIC PCS 7 SCADA layer, the HMI screen tag assignments linked to the SINEC H1 data blocks must be verified after module replacement. Tag addresses referencing specific DB numbers and data word offsets will remain valid provided the replacement module is configured with the same logical address as the original. Any deviation will cause HMI communication faults and require tag remapping in the WinCC project.
In multi-rack S5 configurations using IM 360/IM 361 inter-rack cables or IM 314 interface modules, confirm that the expansion rack slot assignments are unchanged after the retrofit. Systems that also incorporate PROFIBUS DP communication via a CP 5431 FMS/DP or CP 5412 A2 module should have their PROFIBUS network addresses and GSD file configurations reviewed to ensure no address conflicts arise during the migration window. Programming cable connections — typically via a PG 702, PG 740, or PC adapter with STEP 5 software — should be prepared in advance to allow rapid online diagnostics and parameter download immediately after physical installation.
Downtime Control During System Migration
Minimizing production downtime during an S5 communication module replacement requires a structured pre-outage preparation protocol. Before the maintenance window opens, download and archive the complete STEP 5 project from the CPU using a programming device. Verify that all DB blocks associated with the FUM308 — including the send and receive data blocks and the parameter assignment block — are saved and version-controlled. If the system supports online backup via the SINEC H1 network, capture a network snapshot to document active connections and data exchange partners.
During the physical swap, power down the S5 rack in the correct sequence: disable field outputs first, then remove power from the CPU, and finally extract the FUM308 from its slot. Insert the replacement 6DP1308-8AA, restore rack power, and use STEP 5 to perform an online module check before re-enabling field outputs. This sequence protects the original ladder logic and function block program stored in the CPU from corruption and ensures that the control system resumes from a known-good state.
For systems where a cold restart is not acceptable, consider staging a parallel communication path using a temporary CP 1430 TCP or CP 5431 module in an adjacent slot to maintain SCADA connectivity during the swap interval. This approach is particularly valuable in continuous-process environments — such as chemical dosing, water treatment, or power distribution — where a complete communication blackout would trigger safety interlocks or process alarms. After the replacement FUM308 is confirmed online and all SINEC H1 connections are re-established, the temporary parallel path can be decommissioned cleanly.
Retrofit Support FAQ
Q1: Is the 6DP1308-8AA a direct drop-in replacement for my existing FUM308 unit?
Yes. The 6DP1308-8AA and FUM308 designations refer to the same module. Provided your replacement unit carries the same firmware revision as the original, it will install into the same S5 rack slot and accept the same STEP 5 parameter assignment without modification. If the firmware revision differs, a parameter re-download via STEP 5 is recommended before going live.
Q2: What commissioning steps are required after installing the replacement module?
After physical installation, connect a programming device running STEP 5 to the CPU’s programming port. Perform an online module recognition check, then download the saved DB configuration to the FUM308. Verify that the SINEC H1 network status LEDs indicate an active connection, and confirm data exchange with all configured communication partners before re-enabling field outputs.
Q3: Can the 6DP1308-8AA be used as part of a migration from SIMATIC S5 to S7?
The FUM308 is an S5-native module and does not install in S7 racks. However, it is commonly used to maintain S5 system stability during a phased migration, allowing the S5 platform to continue operating while S7-1200 or S7-1500 controllers are commissioned in parallel. Once the S7 system is validated, the S5 rack — including the FUM308 — can be decommissioned in a controlled shutdown.
Q4: What does the 12-month warranty cover?
The 12-month warranty covers manufacturing defects and functional failures under normal operating conditions. Each unit is function-tested prior to shipment. Warranty claims are supported by our technical team; contact [email protected] with your order reference and a description of the fault. Physical damage caused by incorrect installation, overvoltage, or environmental contamination is excluded from warranty coverage.