Siemens 6ES5926-3KA12 Retrofit-Ready CPU for S5-115U Control Systems
The Siemens 6ES5926-3KA12 is the CPU926 central processing unit designed for the SIMATIC S5-115U programmable logic controller platform. As legacy S5-series systems reach end-of-life and original spare parts become increasingly scarce, the 6ES5926-3KA12 remains a critical component for engineers managing aging production lines, retrofit projects, and controlled migration paths toward modern automation architectures. Whether you are replacing a failed CPU in an active production environment or executing a planned upgrade of a legacy control cabinet, this module delivers the processing reliability and interface compatibility that S5-115U installations demand.
The CPU926 supports the standard S5 instruction set and is compatible with the SIMATIC S5-115U rack system, accepting the 6ES5 backplane bus and communicating via the SINEC L1 and SINEC H1 network interfaces where applicable. Engineers undertaking a retrofit must verify the existing power supply unit — typically a 6ES5955-3LC41 or equivalent S5 power supply module — to confirm it can sustain the CPU’s current draw alongside any co-installed I/O modules such as the 6ES5430-4UA12 digital input module or the 6ES5451-4UA13 digital output module. Backplane slot addressing and module configuration data stored in the CPU’s memory must be carefully documented before removal to ensure seamless restoration of the control logic.
Upgrade Compatibility Table
| Parameter | Details |
|---|---|
| Compatible Platform | SIMATIC S5-115U |
| Backplane Interface | S5 Bus (6ES5 series rack) |
| Communication | SINEC L1 / SINEC H1 (via CP modules) |
| Installation Slot | CPU slot, S5-115U central rack |
| Replacement for | 6ES5926-3KA11, 6ES5926-3KA12 (same series) |
| Migration Path | S5 → S7-300 / S7-400 via SIMATIC Migration Tool |
| Commissioning Note | Reload program from EPROM/RAM cartridge; verify DB/FB addresses |
| Warranty | 12 Months — covers functional defects under normal operating conditions |
Retrofit Planning for Existing Automation Systems
A successful retrofit of the 6ES5926-3KA12 begins well before the physical swap. Start by auditing the full contents of the S5-115U control cabinet: document every installed module, including the 6ES5700-series interface modules, any 6ES5318-8MA12 memory submodules, and the programming cable connection — typically a 6ES5734-1BD20 PG cable — used to interface with the SIMATIC S5 programming device or a modern PC running STEP 5 software.
Next, confirm the rack configuration. The S5-115U central rack (6ES5183-3UA11 or equivalent) must have the CPU926 installed in the designated CPU slot. If the system uses expansion racks connected via the 6ES5700-series IM send/receive modules, verify that the inter-rack communication links remain intact after the CPU replacement. Any 6ES5441-4UA13 analog output modules or 6ES5482-4UA11 analog input modules installed in expansion racks must retain their configured module addresses, which are set via hardware switches and must match the address assignments in the S5 program.
For systems that include a SIMATIC S5 HMI interface — such as a legacy OP15 or OP25 operator panel connected via the 6ES5734 programming port — verify that the HMI screen configurations and variable mappings remain consistent with the restored CPU program. Communication links between the CPU and any 6ES5393-series CP communication processors must also be re-established and tested after the module swap. If the retrofit is part of a broader migration toward S7-300 or S7-400 architecture, the SIMATIC S5/S7 migration utility can assist in converting S5 STL code to S7-compatible AWL, reducing manual reprogramming effort.
Downtime Control During System Migration
Minimizing unplanned downtime during a CPU926 replacement requires a structured approach. Before powering down the S5-115U system, use the STEP 5 programming software to perform a full online backup of the CPU’s current program, including all data blocks (DBs), function blocks (FBs), and organization blocks (OBs). Store this backup on both the programming device and an external EPROM cartridge if the system uses one, as the 6ES5926-3KA12 supports program storage via plug-in memory submodules.
During the physical swap, label all terminal wiring connected to I/O modules before disconnection. The S5-115U’s modular design allows I/O modules to remain in the rack while the CPU is replaced, which significantly reduces reconnection risk. After installing the replacement 6ES5926-3KA12, restore the program from the backup source, verify all module addresses, and perform a cold restart sequence. Confirm that all digital and analog I/O signals are responding correctly before returning the system to automatic mode. For critical production lines, consider scheduling the swap during a planned maintenance window and having a tested spare CPU on hand to further compress the replacement window to under two hours.
Retrofit Support FAQ
- Q: Is the 6ES5926-3KA12 a direct drop-in replacement for the 6ES5926-3KA11?
- A: Yes. The 6ES5926-3KA12 is the successor revision of the 6ES5926-3KA11 and is fully compatible with the same S5-115U rack slot, backplane bus, and program memory interface. No hardware modifications are required for the substitution.
- Q: Do I need to reprogram the CPU after replacement?
- A: If the original program is stored on a plug-in EPROM or RAM cartridge, the replacement CPU will load it automatically on startup. If the program resides only in the CPU’s internal RAM, you must reload it from a STEP 5 backup via the programming interface before restarting the system.
- Q: How do I verify wiring and I/O compatibility before going live?
- A: After installing the 6ES5926-3KA12 and restoring the program, perform a forced I/O test in STEP 5 to individually activate and verify each digital and analog channel. Cross-reference the results against the original I/O assignment list to confirm all field devices are responding correctly before switching to RUN mode.
- Q: What does the 12-month warranty cover?
- A: All units are pre-tested for functional operation prior to shipment. The 12-month warranty covers manufacturing defects and functional failures under normal operating conditions. Each module ships with a test report. Contact [email protected] for warranty claims or technical support.