Siemens 6ES7138-4FB03-0AB0 Retrofit-Ready PM-E DC 24V for ET 200S Control Systems
The Siemens 6ES7138-4FB03-0AB0 is a DC 24V power module (PM-E) designed for the ET 200S distributed I/O system, operating within the SIMATIC S7-300 and S7-400 control platforms. As legacy automation lines face increasing pressure to modernize, this module has become a critical retrofit component for engineers managing aging control cabinets, discontinued spare parts, and phased system upgrades. Whether you are replacing a failed unit on a running production line or planning a structured migration from an older SIMATIC ET 200 architecture, the 6ES7138-4FB03-0AB0 delivers the electrical compatibility and mechanical fit required for a smooth, low-risk transition.
This power module supplies the ET 200S terminal modules and I/O modules mounted downstream on the same rail segment. It accepts a DC 24V supply input and distributes regulated power across the connected module group, making it the backbone of any ET 200S power segment. When the original module fails or becomes unavailable through standard distribution channels, sourcing a verified replacement with confirmed firmware and hardware revision compatibility is essential to avoid extended downtime and costly reprogramming.
Upgrade Compatibility Table
| Parameter | Details |
|---|---|
| SKU / Order Number | 6ES7138-4FB03-0AB0 |
| Module Type | PM-E DC 24V Power Module |
| Compatible System | SIMATIC ET 200S Distributed I/O |
| Compatible Controllers | S7-300, S7-400, S7-1500 (via IM 151 interface module) |
| Supply Voltage | DC 24V (19.2V – 28.8V) |
| Installation | 35mm DIN rail, ET 200S terminal module TM-P15S23-A0 |
| Backplane Interface | ET 200S internal bus via terminal module |
| Communication Compatibility | PROFIBUS DP, PROFINET (via IM 151-3 PN) |
| Replaces / Supersedes | 6ES7138-4FB02-0AB0 (earlier hardware revision) |
| Retrofit Recommendation | Direct drop-in replacement; verify terminal module revision |
| Commissioning Note | No parameter download required; hardware-configured module |
| Warranty | 12-Month Warranty included |
Retrofit Planning for Existing Automation Systems
Successful retrofit of the 6ES7138-4FB03-0AB0 begins well before the module arrives on site. Engineers should first audit the existing ET 200S station to confirm the installed terminal module type — the TM-P15S23-A0 is the standard mating terminal module for this PM-E variant, and substituting an incompatible terminal module will prevent proper bus connection. Downstream I/O modules such as the 6ES7131-4BF00-0AA0 (4DI DC 24V) and 6ES7132-4BF00-0AA0 (4DO DC 24V/0.5A) must remain within the power segment’s rated current budget; exceeding the PM-E’s output capacity will trigger a bus fault and halt the entire station.
For stations communicating over PROFIBUS DP, the interface module 6ES7151-1AA05-0AB0 (IM 151-1 Standard) manages the slave address and GSD file configuration. If the site is migrating from PROFIBUS to PROFINET, the replacement interface module 6ES7151-3BA23-0AB0 (IM 151-3 PN) must be configured with a new device name and IP address in the TIA Portal or STEP 7 hardware configuration before the station can be recognized by the S7-1500 controller. This protocol migration step is independent of the PM-E replacement but is frequently performed in the same maintenance window to minimize future downtime.
Power supply sizing is a common oversight during ET 200S retrofits. The 6ES7138-4FB03-0AB0 draws its supply from the 24VDC rail in the control cabinet. If the existing SITOP PSU100S 24V/10A or equivalent power supply is already operating near capacity due to added I/O modules or HMI panels, the retrofit is an appropriate time to upsize the supply or add a secondary power segment with an additional PM-E module. Always measure actual current draw under load before finalizing the power budget.
HMI screens built on SIMATIC WinCC or a KTP700 Basic panel that display ET 200S station diagnostics may require tag updates if the station address or slot assignment changes during the retrofit. In most direct replacement scenarios where the module occupies the same slot position, HMI tags remain valid. However, if the retrofit involves restructuring the station — for example, inserting an additional power segment or relocating modules — the HMI project must be updated and downloaded before resuming production. Programming cables such as the 6ES7972-0CB20-0XA0 (PC Adapter USB) remain compatible with both STEP 7 Classic and TIA Portal environments and are recommended for on-site program backup prior to any hardware change.
Downtime Control During System Migration
Minimizing unplanned downtime during an ET 200S power module replacement requires a structured pre-work checklist. Before removing the 6ES7138-4FB03-0AB0, back up the complete S7 program — including all data blocks, organization blocks, and hardware configuration — to a laptop running STEP 7 or TIA Portal. Confirm that the CPU is in STOP mode and that the 24VDC supply to the affected power segment has been isolated and locked out per site safety procedures.
Because the PM-E is a hardware-configured module with no downloadable parameters, the replacement procedure does not require a new program download to the CPU in a direct swap scenario. The CPU will automatically recognize the module upon power-up and resume normal operation, provided the hardware configuration in the project matches the installed module order number. If the project was configured with the earlier revision 6ES7138-4FB02-0AB0, update the hardware configuration to reflect the -0AB0 revision and perform a hardware download to the CPU before restarting the station.
For multi-station PROFIBUS networks, isolate the affected slave station before beginning work to prevent the master CPU from generating persistent diagnostic alarms that could affect other stations on the same network segment. After replacement, bring the station back online and verify the diagnostic buffer in the CPU shows no active faults before returning the line to production. Target total replacement time for a prepared technician is under 30 minutes for a direct swap, keeping production interruption to a single shift break in most facilities.
Retrofit Support FAQ
Q1: Is the 6ES7138-4FB03-0AB0 a direct replacement for the 6ES7138-4FB02-0AB0?
Yes. The -0AB0 hardware revision is the current production revision and is mechanically and electrically compatible with the earlier -0AB0 and predecessor revisions. In most cases, no hardware configuration change is required. If your STEP 7 or TIA Portal project was configured with an earlier revision, update the hardware catalog entry and download the updated configuration to the CPU to clear any revision mismatch warnings.
Q2: What commissioning steps are required after installing the replacement module?
For a direct slot-for-slot replacement, power up the ET 200S station and verify that the CPU diagnostic buffer shows no active faults for the affected station. Check the module’s PWR LED — steady green indicates correct 24VDC supply. No parameter download is required for the PM-E module itself. If the station was reconfigured or the interface module was also replaced, perform a full hardware configuration download from TIA Portal or STEP 7 before restarting the process.
Q3: How do I verify wiring compatibility before installation?
Confirm that the mating terminal module is the TM-P15S23-A0 and that the 24VDC supply wiring is connected to the correct L+ and M terminals on the terminal module. Measure supply voltage at the terminal module under load to confirm it remains within the 19.2V–28.8V operating range. Check that the total current draw of all modules in the power segment does not exceed the PM-E’s rated output. Refer to the ET 200S system manual (A5E00515771) for detailed wiring diagrams and current derating tables.
Q4: What does the 12-month warranty cover?
All units are supplied with a 12-month warranty covering manufacturing defects and functional failures under normal operating conditions. Each module undergoes outgoing inspection and functional testing prior to shipment. Warranty claims are supported by our technical team at [email protected]. Warranty does not cover damage resulting from incorrect installation, overvoltage, or operation outside the specified environmental conditions.