Automation Part • SmartNexMSK Catalog

Siemens 6ES7590-1AE80-0AA0 Retrofit-Ready Mounting Rail

Siemens 6ES7590-1AE80-0AA0 retrofit-ready 482mm mounting rail for S7-1500. Drop-in replacement, 12-month warranty, compatibility verified, fast shipping.

SKU / Model 6ES7590-1AE80-0AA0
Brand Siemens
Product Type Mounting Rail
Series SIMATIC
Country of Origin DE
Catalog Category Business & Industrial > Automation, Control & Flow Devices > Programmable Logic Controllers
Model checkSKU and compatibility Quality evidencePhotos on request Export supportPacking and delivery
Description

Siemens 6ES7590-1AE80-0AA0 Retrofit-Ready Mounting Rail Overview

Siemens 6ES7590-1AE80-0AA0 Retrofit-Ready Mounting Rail for S7-1500 Control Systems

The Siemens 6ES7590-1AE80-0AA0 is a 482mm (19-inch rack standard) mounting rail designed for the SIMATIC S7-1500 programmable logic controller platform. As legacy S7-300 and S7-400 installations reach end-of-life and facilities transition to modern S7-1500 architectures, this mounting rail serves as the structural backbone for new and retrofit control cabinet builds. Whether you are replacing a damaged rail in an existing S7-1500 rack, expanding an automation panel, or migrating from an older SIMATIC platform, the 6ES7590-1AE80-0AA0 provides a verified, drop-in-compatible solution with no firmware changes required.

This rail supports the full range of S7-1500 CPU modules — including the CPU 1511-1 PN, CPU 1513-1 PN, CPU 1515-2 PN, and CPU 1517-3 PN/DP — as well as associated PS 60W 24/48/60VDC HF power supply modules and PM 70W 120/230VAC system power modules. The rail’s standardized DIN mounting geometry ensures compatibility with all S7-1500 I/O modules, including digital input modules such as the DI 32×24VDC HF, digital output modules such as the DQ 32×24VDC/0.5A HF, and analog modules in the AI/AQ series. Communication modules including CM PtP RS422/485 HF and CP 1543-1 Ethernet communication processors mount directly to this rail without adapter brackets.

Upgrade Compatibility Table

Parameter Details
Part Number 6ES7590-1AE80-0AA0
Compatible Platform SIMATIC S7-1500 (all CPU variants)
Rail Length 482 mm (19-inch rack standard)
Mounting Interface Standard DIN rail profile; direct snap-fit for all S7-1500 modules
Replaces / Upgrades From S7-300 mounting rails (6ES7390-1AE80-0AA0 and variants); requires module migration
Communication Compatibility PROFINET, PROFIBUS DP, Industrial Ethernet — all S7-1500 CM/CP modules supported
Installation Requirement Panel cutout per S7-1500 system manual; grounding screw torque 1.5 Nm
Retrofit Recommendation Verify cabinet depth ≥ 210 mm; confirm PE grounding continuity before module installation
Commissioning Notes Assign module slot addresses in TIA Portal V16+; verify backplane bus integrity after seating all modules
Warranty 12 months from date of shipment; includes functional test certificate

Retrofit Planning for Existing Automation Systems

When planning a control cabinet retrofit around the 6ES7590-1AE80-0AA0 mounting rail, engineers must account for the full module population that will be installed on the rail. A typical S7-1500 retrofit build begins with the PS 60W 24/48/60VDC HF load power supply positioned at the left end of the rail, followed by the CPU module, and then I/O and communication modules arranged by functional group. If the existing cabinet previously housed an S7-300 system, the older 6ES7390-1AE80-0AA0 S7-300 mounting rail must be removed entirely, as S7-300 modules are not mechanically or electrically compatible with the S7-1500 backplane bus architecture.

Terminal wiring from field devices — sensors, actuators, and drives — must be re-mapped to the new I/O module terminal blocks. S7-1500 I/O modules use push-in terminal technology, which differs from the screw terminals common on older S7-300 SM modules. Engineers should prepare updated wiring diagrams referencing the new DI 32×24VDC HF or DQ 32×24VDC/0.5A HF terminal assignments before beginning field reconnection. Analog signal modules such as the AI 8×U/I/RTD/TC ST require shielded cable connections and correct channel parameterization in TIA Portal to maintain measurement accuracy after migration.

For systems that previously used PROFIBUS DP as the primary fieldbus, the retrofit plan should include a CM DP communication module or evaluate whether field devices can be migrated to PROFINET. The CP 1543-1 provides secure Industrial Ethernet connectivity for remote diagnostics and OPC UA data exchange, which is particularly valuable in modernization projects where SCADA or MES integration is required. HMI panels connected to the legacy system — such as SIMATIC TP700 or TP1200 Comfort panels — must have their communication driver updated from S7-300 to S7-1500 addressing in WinCC Comfort/Advanced before going live.

Backplane bus integrity is critical: after seating all modules on the 6ES7590-1AE80-0AA0 rail, verify that each module’s bus connector is fully engaged and that no module is installed beyond the maximum slot count supported by the CPU variant in use. The CPU 1511-1 PN supports up to 32 modules per rack, while the CPU 1517-3 PN/DP supports up to 32 modules with extended I/O via ET 200MP distributed I/O stations connected over PROFINET.

Downtime Control During System Migration

Minimizing production downtime during a mounting rail replacement or full S7-1500 retrofit requires careful pre-staging. Before the maintenance window opens, the existing S7-300 or S7-1500 program should be uploaded and archived from the CPU using TIA Portal’s “Upload from device” function. All hardware configuration data, including module addresses, I/O symbolic names, and network topology, should be saved to a project backup. If the CPU being replaced is a CPU 315-2 PN/DP or similar S7-300 unit, the program logic must be reviewed for compatibility with S7-1500 instruction sets — most standard FB/FC blocks migrate cleanly, but legacy SFCs and system data blocks may require manual adaptation.

Pre-assemble the new S7-1500 rack on the 6ES7590-1AE80-0AA0 mounting rail on a bench, load the adapted program, and perform a functional test with simulated I/O signals before the cutover window. During the cutover, label all field wiring before disconnection, swap the rail assembly, reconnect terminals per the updated wiring diagram, and restore power. A structured commissioning checklist — covering power supply output voltage, CPU RUN/STOP status, PROFINET device recognition, and first I/O scan verification — reduces the risk of extended downtime. With proper pre-staging, most S7-1500 rail replacements can be completed within a 4–8 hour planned maintenance window.

Retrofit Support FAQ

Q1: Is the 6ES7590-1AE80-0AA0 a direct replacement for the S7-300 mounting rail 6ES7390-1AE80-0AA0?
No. While both rails share the same 482mm length, the S7-1500 rail (6ES7590-1AE80-0AA0) uses a different backplane bus connector geometry and module locking mechanism. S7-300 modules cannot be installed on the S7-1500 rail. This rail is the correct choice when migrating to or expanding an S7-1500 system.

Q2: What TIA Portal version is required to commission modules on this rail?
TIA Portal V15.1 or higher is required for S7-1500 hardware configuration. TIA Portal V16 or V17 is recommended for access to the latest CPU firmware features, safety functions, and OPC UA server configuration. Ensure your engineering workstation meets the minimum RAM and OS requirements before beginning the project.

Q3: Does the rail ship with a functional test certificate?
Yes. All units supplied by SMARTNEXMSK are inspected and shipped with a functional test record. The 12-month warranty covers manufacturing defects and verified compatibility with the S7-1500 platform. Units are packaged in anti-static protective packaging suitable for international air and sea freight.

Q4: Can this rail be used in a distributed I/O configuration with ET 200MP?
Yes. The ET 200MP distributed I/O station uses the same 6ES7590-1AE80-0AA0 mounting rail as the central S7-1500 rack. This makes it straightforward to standardize spare parts across both central and distributed I/O cabinets in large-scale automation projects, reducing inventory complexity and procurement lead time.


© 2026 SMARTNEXMSK. All rights reserved.
Original Source: https://smartnexmsk.com
Contact: [email protected] | +86 18259474341

Catalog Paths

Continue from this exact model

Use the live catalog paths below to compare the same brand, product type, or series before sending your RFQ.

RFQ Intent Desk

Choose the right sourcing path for this model

Each action carries the product model and intent into the inquiry record so the sales follow-up starts with useful context.

Exact Model Quote

Use this path when the SKU, brand, quantity, and destination are already confirmed.

Start
Replacement Check

Use this path for old, obsolete, or uncertain models that need compatibility review.

Start
Quality Confirmation

Ask for label photos, packing notes, documentation, or pre-shipment checks.

Start
Urgent Dispatch

Route downtime or maintenance requests with target dispatch timing and courier country.

Start
Request Quote WhatsApp Email