Siemens 6SL3120-1TE24-5AA1 Retrofit-Ready Single Motor Module for SINAMICS S120 Control Systems
The Siemens 6SL3120-1TE24-5AA1 is a Booksize Single Motor Module within the SINAMICS S120 drive platform, rated at 45A continuous output current and designed for precise, high-dynamic servo and vector control applications. As legacy SINAMICS S120 Booksize components approach end-of-life or become increasingly difficult to source through standard distribution channels, the 6SL3120-1TE24-5AA1 serves as a verified retrofit-ready replacement that preserves existing control architecture, minimizes re-engineering effort, and restores full drive functionality with minimal downtime.
This module is engineered for direct installation into existing S120 Booksize drive line-ups. It interfaces natively with the SINAMICS S120 Control Unit — including the CU320-2 DP and CU320-2 PN — via the DRIVE-CLiQ communication backbone, eliminating the need for protocol conversion or additional gateway hardware. The module’s firmware is compatible with STARTER and SINAMICS Startdrive commissioning environments, allowing engineers to restore or migrate drive parameterization from existing project files with minimal manual reconfiguration.
When planning a retrofit or spare-parts replacement using the 6SL3120-1TE24-5AA1, engineers should verify several critical system parameters before installation. DC bus voltage compatibility must be confirmed against the existing Active Line Module or Smart Line Module — typically the 6SL3130-7TE28-4AA3 or 6SL3130-6AE21-0AB0 — to ensure the shared DC link operates within specification. Terminal wiring on the motor side should be checked against the existing cable cross-section and connector type, as Booksize modules use a specific power connector layout that must match the installed motor cable assembly.
Backplane slot assignment and module addressing within the drive line-up must be reconfigured in the Control Unit if the physical slot position changes during replacement. The DRIVE-CLiQ topology, which links the 6SL3120-1TE24-5AA1 to the Control Unit and to downstream components such as the SMC30 encoder evaluation module or the TM31 terminal module, must be re-scanned and validated after installation. Any changes to the DRIVE-CLiQ chain — including the addition or removal of a Sensor Module Cabinet-Mounted (SMC) or a Terminal Module — will require a topology update in the commissioning tool before the drive can be enabled.
For systems that include an HMI interface — such as a SIMATIC TP700 or TP1200 Comfort Panel connected via PROFINET or PROFIBUS — the drive object number and axis assignment in the HMI project must be verified to ensure that screen objects, alarm messages, and diagnostic displays continue to reference the correct drive axis after the module swap. If the original module was parameterized with a specific motor data set, the motor nameplate data and encoder type (HTL, TTL, or resolver via SMC10/SMC20) must be re-entered or transferred from the existing project backup.
Communication link integrity should be confirmed end-to-end: from the Control Unit through the DRIVE-CLiQ wiring to the 6SL3120-1TE24-5AA1, and from the Control Unit upstream to the SIMATIC S7-300, S7-400, or S7-1500 PLC via PROFIBUS DP or PROFINET IO. If the system uses a CX32-2 Controller Extension to distribute axis control across multiple Booksize modules, the axis assignment and synchronization settings must be reviewed after the replacement module is commissioned. All units are pre-tested prior to shipment and covered by a 12-month warranty.
Upgrade Compatibility Table
| Parameter | Details |
|---|---|
| SKU / Order Number | 6SL3120-1TE24-5AA1 |
| Product Series | SINAMICS S120 Booksize |
| Output Current | 45A continuous |
| DC Bus Interface | Shared DC link, compatible with S120 Active Line Module and Smart Line Module |
| Communication Interface | DRIVE-CLiQ (native, no gateway required) |
| Control Unit Compatibility | CU320-2 DP, CU320-2 PN, CX32-2 |
| Commissioning Tool | STARTER v4.x+, SINAMICS Startdrive (TIA Portal V14+) |
| Encoder Support | Via SMC10, SMC20, SMC30 (HTL, TTL, resolver, EnDat) |
| Installation Format | Booksize, DIN rail / panel mount in S120 drive line-up |
| Replacement Scope | Direct drop-in for same-rating Booksize Single Motor Modules |
| Commissioning Notes | DRIVE-CLiQ topology rescan required; motor data re-entry recommended |
| Warranty | 12 months from date of shipment |
Retrofit Planning for Existing Automation Systems
Successful integration of the 6SL3120-1TE24-5AA1 into an existing automation system requires a structured approach that accounts for both the drive hardware and the surrounding control infrastructure. In a typical S120 Booksize cabinet, the motor module shares a DC bus with other Booksize components — potentially including additional Single Motor Modules, Double Motor Modules such as the 6SL3120-2TE21-8AA3, and a Braking Module for regenerative energy management. The total DC bus load must be recalculated if the replacement module’s rated current differs from the original, and the Active Line Module capacity must be confirmed to be sufficient for the updated drive line-up.
The SINAMICS S120 Booksize system typically relies on a 24VDC auxiliary power supply — often sourced from a SITOP PSU100S or equivalent — to power the Control Unit, DRIVE-CLiQ components, and terminal modules such as the TM31 or TM41. Before replacing the motor module, verify that the auxiliary supply has sufficient current capacity to support all connected DRIVE-CLiQ nodes, including the replacement module’s internal electronics. The 24VDC wiring harness and connector on the Booksize module must be inspected and reconnected correctly after installation.
If the system includes a Voltage Sensing Module (VSM10) for line voltage monitoring, or a Cabinet Module for thermal management, these components remain unaffected by the motor module replacement but should be inspected for condition and firmware version compatibility during the retrofit window. Similarly, if a Safe Torque Off (STO) or Safe Stop 1 (SS1) safety function is implemented via the onboard safety terminals of the 6SL3120-1TE24-5AA1, the safety wiring and parameterization must be re-validated and documented in accordance with the applicable functional safety standard before the system is returned to service.
For systems where the original motor module was connected to a SIMATIC ET 200SP or ET 200M distributed I/O rack via PROFINET, the I/O configuration in the TIA Portal or STEP 7 project must be reviewed to confirm that no drive-related I/O signals are mapped through the motor module’s onboard terminals in a way that would be disrupted by the replacement. A pre-commissioning checklist should include verification of all analog and digital I/O assignments, interlock logic in the PLC program, and any speed or torque reference signals sourced from the controller.
Downtime Control During System Migration
Minimizing production downtime during a motor module replacement requires advance preparation and a disciplined commissioning sequence. Before the maintenance window begins, a full backup of the Control Unit project — including all drive object parameters, safety parameters, and DRIVE-CLiQ topology data — should be exported from STARTER or Startdrive and stored securely. This backup enables rapid restoration of the original configuration if the replacement module requires parameter transfer rather than a fresh commissioning cycle.
During the physical swap, the DC bus must be fully discharged before any Booksize module is removed. The discharge time for S120 Booksize systems is typically five minutes after mains disconnection, but should be confirmed by measuring the DC bus voltage directly. Once the 6SL3120-1TE24-5AA1 is installed and DRIVE-CLiQ connections are secured, the Control Unit will perform an automatic topology scan on power-up. If the new module is detected in the same slot with the same rating, the existing parameter set will be applied automatically, significantly reducing recommissioning time.
If the motor data set or encoder configuration requires adjustment, the commissioning engineer should use the drive’s built-in motor identification routine to verify current controller gains and flux model accuracy before returning the axis to automatic control. A test run at reduced speed and load — with the PLC in manual mode and the HMI displaying live drive diagnostics — should be completed before handing the system back to production. All test results, parameter changes, and wiring modifications should be documented in the plant maintenance record. Units supplied by SMARTNEXMSK are pre-tested under load conditions prior to shipment, supporting a faster and more confident on-site commissioning process.
Retrofit Support FAQ
Q: Is the 6SL3120-1TE24-5AA1 a direct replacement for my existing S120 Booksize Single Motor Module?
A: Yes, provided the existing module has the same current rating (45A) and is installed in a Booksize drive line-up. The 6SL3120-1TE24-5AA1 uses the same DC bus connector, DRIVE-CLiQ interface, and Booksize mechanical format. A DRIVE-CLiQ topology rescan is required after installation, and motor data should be verified or re-entered from the original project backup.
Q: What commissioning steps are required after installing the replacement module?
A: After physical installation, power up the Control Unit and allow the automatic DRIVE-CLiQ topology scan to complete. Confirm that the module is recognized in STARTER or Startdrive. Verify motor data, encoder type, and safety function parameterization. Perform a no-load test run, then a loaded test run at reduced speed before returning to full production. Document all parameter changes.
Q: Can I use this module if my system uses PROFIBUS DP instead of PROFINET?
A: Yes. The 6SL3120-1TE24-5AA1 communicates with the Control Unit via DRIVE-CLiQ, which is independent of the fieldbus protocol used between the Control Unit and the PLC. Whether your CU320-2 DP uses PROFIBUS or your CU320-2 PN uses PROFINET, the motor module interface is identical. No changes to the fieldbus configuration are required as a result of the motor module replacement.
Q: What warranty and pre-shipment testing does SMARTNEXMSK provide?
A: All units are functionally tested prior to shipment to verify power stage integrity, DRIVE-CLiQ communication, and auxiliary power operation. A 12-month warranty is provided from the date of shipment, covering manufacturing defects and functional failures under normal operating conditions. Technical support for installation and commissioning questions is available through our sales team.
© 2026 SMARTNEXMSK. All rights reserved.
Original Source: https://smartnexmsk.com
Contact: [email protected] | +86 18259474341