Siemens 6SL3120-2TE15-0AA4 Retrofit-Ready Double Motor Module for SINAMICS S120 Control Systems
The Siemens 6SL3120-2TE15-0AA4 is a Booksize Double Motor Module designed for the SINAMICS S120 drive platform, delivering dual-axis servo control within a compact, rail-mounted form factor. As legacy S120 Booksize installations approach end-of-service milestones, this module serves as the verified retrofit and replacement solution for discontinued or damaged units across a wide range of industrial automation environments — including CNC machining centers, packaging lines, printing presses, textile machinery, and multi-axis handling systems.
Whether you are replacing a failed 6SL3120-2TE13-0AA3 or upgrading from an earlier Booksize generation, the 6SL3120-2TE15-0AA4 integrates directly into existing S120 Booksize Control Unit assemblies. It is compatible with the CU320-2 PN and CU320-2 DP Control Units and communicates via DRIVE-CLiQ, Siemens’ proprietary high-speed drive topology bus. The module supports both vector control and servo control modes, making it suitable for demanding positioning and speed-regulation applications.
Before installation, engineers should verify the following: DC link bus voltage compatibility with the existing Line Module (such as the 6SL3130-series Active Line Module or Smart Line Module), available slot positions on the Booksize mounting rail, DRIVE-CLiQ port availability on the Control Unit, and firmware version alignment between the new module and the existing CU firmware. Siemens STARTER or Sinamics Startdrive (TIA Portal) commissioning software should be used to assign the drive object, configure axis parameters, and validate encoder feedback from the connected 1FK7 or 1FT7 servo motors.
Upgrade Compatibility Table
| Parameter | Details |
|---|---|
| SKU / Order Number | 6SL3120-2TE15-0AA4 |
| Product Series | SINAMICS S120 Booksize |
| Module Type | Double Motor Module |
| DC Link Voltage | 600 V DC |
| Output Current (per axis) | 5 A |
| Communication Interface | DRIVE-CLiQ |
| Compatible Control Units | CU320-2 PN, CU320-2 DP |
| Mounting | Booksize rail, shared DC bus |
| Replaces / Upgrades From | 6SL3120-2TE13-0AA3, 6SL3120-2TE11-0AA3 and earlier Booksize variants |
| Commissioning Tool | STARTER / Sinamics Startdrive (TIA Portal V15+) |
| Firmware Alignment | Required — match CU firmware version before go-live |
| Warranty | 12 Months |
| Condition | New / Surplus New |
| Origin | Germany |
Retrofit Planning for Existing Automation Systems
A successful retrofit of the 6SL3120-2TE15-0AA4 into an existing S120 Booksize cabinet begins with a thorough audit of the current drive topology. Start by documenting the existing DRIVE-CLiQ wiring diagram — each module in the daisy chain must be accounted for, including any SMC30 Sensor Module Cabinet-Mounted units used for encoder evaluation, and any TM31 Terminal Module or TM41 Terminal Module providing supplementary I/O expansion. Verify that the 6SL3130-series Line Module (Active or Smart) supplying the shared DC bus has sufficient power headroom to support the replacement module’s rated output.
Terminal wiring at the motor output connectors (X1 and X2) must be re-verified against the motor nameplate data for the connected 1FK7 or 1FT7 servo motors. Pay particular attention to PE grounding continuity, shield termination at the cable entry gland, and correct phase sequence. If the existing motor power cables are routed through a 6SL3060-series cable duct or Booksize cable management system, inspect for insulation wear before re-use.
Module address assignment is handled automatically via DRIVE-CLiQ topology recognition, but the drive object number within the Control Unit project must be re-mapped if the physical slot position changes. Export the existing project from STARTER or TIA Portal before any hardware swap, and use the “Automatic Configuration” function after the new module is powered to allow the CU320-2 to detect and register the 6SL3120-2TE15-0AA4. Cross-check the axis parameter sets — particularly speed limits, torque limits, and encoder resolution — against the original commissioning records.
For sites running PROFIBUS DP communication alongside DRIVE-CLiQ, confirm that the DP slave address and GSD file version remain consistent with the PLC program on the SIMATIC S7-300 or S7-400 controller. If the site has migrated to PROFINET, the CU320-2 PN variant supports direct integration without additional communication modules. HMI screens on connected SIMATIC TP or MP panels should be validated post-commissioning to confirm that drive status words, fault codes, and speed setpoint channels are correctly mapped.
Downtime Control During System Migration
Minimizing production downtime during a Booksize module swap requires careful pre-staging. Before the maintenance window opens, pre-configure the replacement 6SL3120-2TE15-0AA4 offline using a laptop with Sinamics Startdrive or STARTER installed. Load the exported drive project, assign the correct drive object, and perform a parameter download simulation to catch any version conflicts before the module reaches the cabinet.
During the physical swap, power down the entire Booksize assembly via the upstream circuit breaker — do not rely solely on the Safe Torque Off (STO) function for full isolation. Discharge the DC link capacitors fully (allow a minimum of 5 minutes after power-off, or verify with a calibrated voltmeter) before disconnecting the DC bus bar connectors. Label all DRIVE-CLiQ cables before removal to prevent mis-routing during reassembly.
After mechanical installation and cable reconnection, perform a controlled power-up sequence: energize the Line Module first, confirm DC link voltage stabilization, then enable the Motor Module. Use the fault buffer readout on the CU320-2 or the connected HMI to confirm fault-free initialization. Run a low-speed jog test on each axis before releasing the machine to production. With proper pre-staging, total downtime for a single module replacement can typically be contained to under four hours, preserving the original program logic and field control continuity without requiring a full re-commissioning cycle.
Retrofit Support FAQ
Q1: Is the 6SL3120-2TE15-0AA4 a direct drop-in replacement for the 6SL3120-2TE13-0AA3?
A: Mechanically and electrically, yes — both are Booksize Double Motor Modules sharing the same DC bus connector and DRIVE-CLiQ interface. However, a firmware version check is required. If the existing CU320-2 firmware is below V4.7, a firmware update is recommended before installing the 6SL3120-2TE15-0AA4 to ensure full parameter compatibility and access to current safety functions.
Q2: What pre-shipment testing is performed on this module?
A: Each 6SL3120-2TE15-0AA4 unit undergoes functional power-on verification and output stage continuity testing prior to dispatch. Units are shipped with original or equivalent protective packaging. A 12-month warranty covers manufacturing defects and functional failures under normal operating conditions.
Q3: Can this module be used with PROFIBUS DP without a CU320-2 DP Control Unit?
A: The Motor Module itself does not carry a fieldbus interface — communication is handled exclusively through DRIVE-CLiQ to the Control Unit. PROFIBUS DP connectivity depends on the Control Unit variant (CU320-2 DP) or an external CBE20 Communication Board Extension. Confirm your Control Unit variant before ordering.
Q4: What is the lead time and warranty coverage?
A: In-stock units ship within 1–3 business days. All units carry a 12-month warranty from the date of shipment. Warranty claims are supported by our technical team with RMA processing and replacement dispatch within 5 business days of confirmed fault diagnosis.