Siemens 6SL3352-1AG38-8FA1 Retrofit-Ready Motor Module for S120 Chassis Control Systems
The Siemens 6SL3352-1AG38-8FA1 is a high-current SINAMICS S120 Chassis Motor Module rated at 380A, designed for demanding industrial drive applications in manufacturing, heavy process, and infrastructure automation. As legacy S120 Chassis units reach end-of-service milestones or become unavailable through standard supply channels, the 6SL3352-1AG38-8FA1 has become a critical retrofit and replacement component for engineers managing aging control systems, upgrading drive cabinets, or restoring production lines after unplanned failures.
This module operates within the SINAMICS S120 drive platform, sharing the same DC bus architecture, DRIVE-CLiQ communication backbone, and booksize/chassis mounting conventions that define the S120 family. It is fully compatible with the S120 Control Unit CU320-2 DP and CU320-2 PN, and integrates directly with the SINAMICS S120 Line Module — whether an Active Line Module (ALM) or Basic Line Module (BLM) — without requiring firmware re-engineering or hardware adaptation in most standard retrofit scenarios.
Upgrade Compatibility Table
| Parameter | Details |
|---|---|
| SKU / Part Number | 6SL3352-1AG38-8FA1 |
| Series | SINAMICS S120 Chassis |
| Rated Output Current | 380A |
| Communication Interface | DRIVE-CLiQ |
| Backplane / DC Bus | S120 Chassis DC Bus Bar |
| Compatible Control Units | CU320-2 DP, CU320-2 PN |
| Compatible Line Modules | ALM / BLM (S120 Chassis) |
| Mounting | Chassis (floor-standing cabinet) |
| Cooling | Internal fan / forced air |
| Retrofit Recommendation | Direct replacement for same-rated S120 Chassis Motor Modules |
| Commissioning Tool | STARTER / TIA Portal Startdrive |
| Firmware Compatibility | SINAMICS S120 firmware V4.x and above |
| Warranty | 12 Months |
| Origin | Germany |
| Condition | New / Surplus New |
Retrofit Planning for Existing Automation Systems
Replacing or upgrading a Chassis Motor Module in an active production environment requires careful pre-engineering to avoid extended downtime and program loss. Before removing the existing module, engineers should document the full drive topology: confirm the DC bus configuration, record all DRIVE-CLiQ node addresses, and export the current drive project from STARTER or TIA Portal Startdrive. The 6SL3352-1AG38-8FA1 uses the same DRIVE-CLiQ port layout as predecessor Chassis Motor Modules, which simplifies cable reconnection during swap-out.
Power supply verification is essential. The upstream Active Line Module or Basic Line Module must be confirmed capable of sustaining the 380A output demand of this Motor Module under peak load conditions. In multi-axis cabinet configurations, the shared DC bus — typically distributed via the S120 Chassis DC Bus Bar — must be de-energized and discharged before any module removal. Capacitor discharge time for high-current Chassis units can exceed five minutes; always verify with a calibrated voltage meter before contact.
Terminal wiring on the motor output side (U2, V2, W2) should be photographed and labeled before disconnection. The PE (protective earth) terminal and motor temperature sensor (KTY84 or PTC) connections must be re-verified after installation. If the existing system uses a Siemens SMC30 Sensor Module Cabinet-Mounted for encoder feedback, confirm that the encoder cable routing and DRIVE-CLiQ connection to the new module are intact before powering up.
For systems using PROFIBUS DP communication via the CU320-2 DP, the drive node address must be re-confirmed in the hardware configuration after module replacement. Systems migrated to PROFINET via the CU320-2 PN should verify IP address assignment and device name in TIA Portal. In either case, the drive object configuration — including speed setpoints, torque limits, ramp times, and safety functions — must be re-downloaded from the saved project file to the new module before commissioning.
Cabinet-level integration should also account for the Siemens SITOP power supply feeding the 24VDC control circuit, the terminal block wiring for enable signals and fault resets, and any existing Siemens OP panel or SIMATIC HMI screen that displays drive status. HMI tag mappings tied to drive parameters (e.g., actual speed, output current, fault codes) should be validated after the module swap to ensure display accuracy. If the system includes a Siemens S7-300 or S7-400 PLC communicating with the drive via PROFIBUS, the GSD file and hardware configuration in STEP 7 or TIA Portal should be reviewed to confirm compatibility with the replacement module’s firmware version.
For I/O-intensive applications, verify that any Digital Input/Output expansion connected through the CU320-2 or via a Terminal Module TM31 or TM41 remains correctly addressed after the module replacement. The TM31 provides additional analog and digital I/O channels that are commonly used in retrofit projects to interface legacy control signals with the S120 platform without rewiring the entire control cabinet.
Downtime Control During System Migration
Minimizing production downtime during a Chassis Motor Module replacement begins with pre-staging. Before the maintenance window opens, the replacement 6SL3352-1AG38-8FA1 should be bench-tested where possible, with firmware updated to match the existing system version using a SINAMICS memory card or direct PC connection via the STARTER commissioning tool. Having the drive project file pre-loaded on the memory card eliminates the need for online parameter entry during the live swap, reducing in-cabinet commissioning time significantly.
During the swap window, follow a structured sequence: isolate and lock out the main supply, discharge the DC bus, disconnect DRIVE-CLiQ cables in labeled order, remove motor power terminals, extract the module, install the replacement, reconnect in reverse order, and restore power in stages — control voltage first, then main power. This sequence protects the original program logic stored in the CU320-2 and avoids accidental parameter overwrite.
After power restoration, perform a controlled test run at reduced speed before returning to full production load. Monitor output current, motor temperature feedback, and fault buffer in real time via STARTER or the HMI. If the system uses safety-integrated functions (STO, SS1, SLS) via the CU320-2, these must be re-validated and signed off per the applicable safety standard before resuming normal operation. Keeping a pre-tested spare 6SL3352-1AG38-8FA1 in local inventory is the most effective strategy for reducing mean time to repair (MTTR) in high-availability production environments.
Retrofit Support FAQ
Q1: Is the 6SL3352-1AG38-8FA1 a direct drop-in replacement for other S120 Chassis Motor Modules?
A: It is a direct replacement for S120 Chassis Motor Modules of the same current rating (380A) and voltage class. Modules with different current ratings require verification of DC bus capacity and motor cable sizing before substitution. Always confirm the firmware version on the replacement module matches or is compatible with the existing CU320-2 firmware.
Q2: What commissioning steps are required after installation?
A: After physical installation and wiring reconnection, download the saved drive project from STARTER or TIA Portal Startdrive to the new module. Verify DRIVE-CLiQ topology recognition, confirm all drive objects are online, check encoder feedback via the SMC30 if applicable, and perform a no-load test run before full production restart. Safety function validation (STO/SS1) must be completed if safety-integrated functions are active.
Q3: How do I verify wiring compatibility before installation?
A: Compare the terminal layout of the 6SL3352-1AG38-8FA1 with the existing module using the SINAMICS S120 Chassis Power Units Hardware Installation Manual. Key terminals to verify include U2/V2/W2 motor output, DC bus connections (P600/N600), PE terminal, motor temperature sensor input, and DRIVE-CLiQ port positions. Photograph all existing wiring before disconnection.
Q4: What does the 12-month warranty cover?
A: The 12-month warranty covers manufacturing defects and functional failures under normal operating conditions. Each unit undergoes pre-shipment functional testing prior to dispatch. Warranty claims require the original invoice and a fault description. Units damaged by incorrect installation, overvoltage, or environmental factors outside the rated specification are not covered. Contact [email protected] for warranty support.