Siemens A5E01105817 Retrofit-Ready Inverter Power Board for SINAMICS G120 & MM440 Control Systems
The Siemens A5E01105817 is a retrofit-ready inverter power board engineered for seamless integration into legacy SINAMICS G120 and MICROMASTER MM440 variable frequency drive systems. As production lines age and original components reach end-of-life, the A5E01105817 provides a verified, drop-in compatible solution that restores full drive functionality without requiring a complete system overhaul. Whether you are managing a planned upgrade cycle or responding to an unplanned failure, this board is stocked, tested, and ready for immediate dispatch with a 12-month warranty.
Industrial facilities running SINAMICS G120 frames — including the CU240E-2, CU250S-2, and PM240-2 power modules — frequently encounter power board degradation caused by thermal cycling, capacitor aging, and transient voltage events. The A5E01105817 addresses these failure modes directly, restoring the drive’s ability to regulate DC bus voltage, manage IGBT gate signals, and maintain communication with the control unit over the PROFIBUS or PROFINET backplane interface. Before installation, engineers should verify the existing frame size, firmware version on the CU module, and the rated input voltage (380–480 V AC, 3-phase) to confirm compatibility with the replacement board.
Upgrade Compatibility Table
| Parameter | Details |
|---|---|
| Compatible Drive Series | SINAMICS G120, MICROMASTER MM440 |
| Compatible Frame Sizes | FSA, FSB, FSC (verify before ordering) |
| Input Voltage | 380–480 V AC, 3-phase, 50/60 Hz |
| Backplane Interface | DRIVE-CLiQ / legacy G120 backplane connector |
| Communication Compatibility | PROFIBUS DP, PROFINET IO (via CU module) |
| Mounting | DIN rail / panel mount, same footprint as OEM |
| Firmware Requirement | CU firmware ≥ V4.7 recommended |
| Retrofit Recommendation | Direct replacement; re-parameterization via STARTER or Startdrive required |
| Commissioning Note | Reset parameters to factory default before loading saved project file |
| Warranty | 12 months from date of shipment |
Retrofit Planning for Existing Automation Systems
Successful retrofit of the A5E01105817 begins well before the board arrives on site. A structured pre-replacement audit should cover the following areas to minimize risk and ensure a smooth cutover.
Power Supply Verification: Confirm that the existing 24 V DC control supply — typically sourced from a SITOP PSU100S or equivalent — can sustain the inrush demand during drive initialization. Undersized supplies are a common cause of post-retrofit faults. If the cabinet also houses a SIMATIC S7-300 or S7-400 PLC with multiple SM modules drawing from the same rail, a dedicated supply for the drive control circuit is strongly recommended.
Terminal Wiring and I/O Mapping: The A5E01105817 retains the same terminal block layout as the original G120 power board. However, if the existing installation uses a TB30 terminal board or a TM31 terminal module for extended I/O, verify that all analog input/output assignments (0–10 V, 4–20 mA) and digital I/O parameterization (P0700, P1000 series) are documented before disconnection. A printed parameter list exported from STARTER software serves as the reference baseline.
Backplane and Rack Integrity: Inspect the G120 backplane connector for pin corrosion or mechanical damage before seating the replacement board. In multi-drive installations sharing a common DC bus with a SINAMICS S120 booksize unit or a BLM/SLM line module, confirm that the DC bus pre-charge sequence is not disrupted by the board swap. The Active Line Module (ALM) must remain online during the replacement if the bus is shared.
Communication Link Continuity: If the drive is integrated into a PROFIBUS segment alongside other field devices — such as ET 200S distributed I/O, SIRIUS 3RW soft starters, or a CP 343-1 communications processor — ensure the PROFIBUS address on the CU module is recorded and re-entered after the board replacement. PROFINET installations should verify the device name assignment via the TIA Portal online diagnostics before returning the drive to automatic mode.
HMI and Visualization: Facilities using a SIMATIC HMI TP700 Comfort or MP377 panel connected to the drive via the PLC program should verify that all drive status words, fault codes, and speed setpoint write addresses remain consistent after re-parameterization. Any changes to the drive’s telegram type (e.g., Standard Telegram 1 vs. Telegram 20) will require corresponding updates in the HMI tag table.
Program Compatibility and Logic Preservation: Upload and archive the existing S7 program from the CPU before beginning the retrofit. If the drive fault response is handled by a STEP 7 or TIA Portal function block (e.g., FB284 SINA_SPEED), confirm that the instance data block references remain valid after the drive is re-commissioned. Test all interlocks — including motor thermistor inputs, safety relay outputs, and emergency stop chains — before releasing the drive to production.
Downtime Control During System Migration
Minimizing unplanned downtime during a power board replacement requires a disciplined sequence of actions. Begin by scheduling the swap during a planned maintenance window and preparing a rollback plan in case the replacement board reveals a secondary fault in the drive system.
Before de-energizing the drive, capture a full parameter backup using STARTER or Startdrive and save the project file to a USB drive or engineering laptop. Note the exact fault history from the drive’s diagnostic buffer — this often reveals whether the power board failure was caused by an upstream event such as a line voltage transient, a motor insulation fault, or a blocked cooling fan.
During the swap, follow the G120 installation manual’s ESD precautions. The A5E01105817 contains sensitive gate driver circuitry that can be damaged by electrostatic discharge. Use a grounded wrist strap and place the board on an anti-static mat during handling. Reconnect all connectors in the reverse order of removal, paying particular attention to the DC bus bar connections and the fan power connector.
After installation, perform a controlled power-up sequence: apply control voltage first, verify that the CU module boots without fault, then apply main power. Use the drive’s built-in motor identification routine (P1910) if the motor data has been lost or if a different motor is being connected. Confirm that the speed feedback signal — whether from a SINAMICS encoder module SMC30 or a pulse encoder connected to the HTL/TTL input — is reading correctly before enabling the drive from the PLC.
Document the completed retrofit with a commissioning report that includes the replacement board serial number, parameter checksum, test run data, and sign-off by the responsible engineer. This record supports the 12-month warranty claim process and provides traceability for future maintenance audits.
Retrofit Support FAQ
Q1: Is the A5E01105817 a direct drop-in replacement for the original G120 power board, or does it require re-parameterization?
The A5E01105817 is mechanically and electrically compatible with the original board, but Siemens requires a full parameter restore after any power board replacement. Load your saved STARTER or Startdrive project file after the board is seated and the CU module has booted successfully. Do not attempt to run the drive without restoring parameters, as factory defaults will not match your motor or application settings.
Q2: Will my existing PROFIBUS or PROFINET configuration be affected by the board swap?
The communication configuration is stored in the CU module, not the power board, so your PROFIBUS address or PROFINET device name will be retained. However, if the CU module was also replaced or reset, you will need to reassign the device name via TIA Portal and verify the GSD/GSDML file version matches the firmware on the new board.
Q3: What wiring checks should I perform before powering up after the replacement?
Verify DC bus bar torque to specification (refer to the G120 installation manual for frame-specific values), confirm the motor cable phase sequence, check the 24 V DC control supply voltage at the CU terminal, and inspect the thermistor/PTC input wiring. A megger test on the motor winding insulation is recommended if the drive tripped on an overcurrent or ground fault before the board failure.
Q4: What does the 12-month warranty cover, and how is it claimed?
The 12-month warranty covers manufacturing defects and component failures under normal operating conditions. It does not cover damage caused by incorrect installation, overvoltage events, or operation outside the rated specifications. To initiate a warranty claim, contact [email protected] with the board serial number, purchase order reference, fault description, and commissioning report. Replacement or repair will be arranged within the agreed lead time.