ABB ACQ580-01-07A2-4 Retrofit-Ready VFD for ACQ580 Systems

ABB ACQ580-01-07A2-4 2.2kW retrofit-ready VFD. Drop-in replacement for ACQ580 series. Compatibility verified, 12-month warranty, fast shipping.

SKUACQ580-01-07A2-4
BrandABB
SeriesACQ580
ABB ACQ580-01-07A2-4 Variable Frequency Drive
Model context is attached to every quote action. Use WhatsApp for urgent downtime, or Email for purchasing records.
Model checkSKU and compatibility review Quality evidencePhotos and label notes when available Export supportPacking, courier, and delivery notes
Product Information

Model Details

SKU / Model ACQ580-01-07A2-4
Brand ABB
Product Type Variable Frequency Drive
Series ACQ580
Catalog Category Business & Industrial > Automation, Control & Flow Devices > Industrial Control Systems > Variable Frequency Drives
Country of Origin SE
Tags ABB, ACQ580, pump-fan-drive, retrofit, VFD
Catalog Paths

Continue from this exact model

Use the live catalog paths below to compare the same brand, product type, or series before sending your RFQ.

RFQ Intent Desk

Choose the right sourcing path for this model

Each action carries the product model and intent into the inquiry record so the sales follow-up starts with useful context.

Exact Model Quote

Use this path when the SKU, brand, quantity, and destination are already confirmed.

Start
Replacement Check

Use this path for old, obsolete, or uncertain models that need compatibility review.

Start
Quality Confirmation

Ask for label photos, packing notes, documentation, or pre-shipment checks.

Start
Urgent Dispatch

Route downtime or maintenance requests with target dispatch timing and courier country.

Start
Description

ABB ACQ580-01-07A2-4 Retrofit-Ready VFD for ACQ580 Systems Overview

ABB ACQ580-01-07A2-4 Retrofit-Ready VFD for ACQ580 Control Systems

The ABB ACQ580-01-07A2-4 is a 2.2 kW (3 HP), 3-phase 380–480 V AC variable frequency drive purpose-built for pump and fan applications in industrial water treatment, HVAC, and process automation environments. As a direct retrofit replacement for legacy ACQ580 series drives, this unit preserves the original control architecture while delivering modern energy-saving algorithms, embedded PID control, and full compliance with IEC 61800-5-1 safety standards. Whether you are recovering from an unplanned drive failure, executing a planned control-cabinet upgrade, or migrating an aging pump station to a current-generation platform, the ACQ580-01-07A2-4 is engineered to minimize engineering rework and commissioning time.

Each unit shipped by SMARTNEXMSK undergoes pre-delivery functional testing covering input/output voltage verification, parameter restore, motor control loop validation, and communication link handshake. All units carry a 12-month warranty against manufacturing defects, with documented test records available upon request.

Upgrade Compatibility Table

n

Attribute ACQ580-01-07A2-4 (This Unit) Retrofit Notes
Power Rating 2.2 kW / 3 HP Verify motor nameplate; matched for standard 2.2 kW pump loads
Supply Voltage 3-phase 380–480 V AC ±10% Confirm site supply voltage before installation
Output Current 7.2 A (continuous) Check cable sizing and overload relay settings on existing panel
Mounting / Frame R1 frame, IP21 standard (IP55 optional) Same footprint as ACQ580 R1; no panel cutout modification required
Control Terminals Standard ACQ580 X1/X2 terminal block layout Existing field wiring reusable; verify terminal torque spec (0.5 N·m)
Communication Embedded Modbus RTU; optional PROFIBUS-DP / PROFINET / EtherNet/IP via FENA/FPBA adapter Retain existing fieldbus adapter if present; re-address node ID in parameters
Parameter Backup Compatible with ACQ580 parameter set (Assistant Control Panel or Drive Composer) Upload saved parameter file; verify application macro selection
Replacement Compatibility Direct replacement for ACQ580-01-07A2-4; functional equivalent for ACS580-01-07A2-4 in pump duty Confirm application macro (Pump PID vs. HVAC) matches original configuration
Commissioning Tool ABB Drive Composer Entry / Pro; ACS-AP-I or ACS-AP-W control panel Use existing panel cable (OPCA-02 or equivalent); no new tooling required
Warranty 12-Month Warranty — covers manufacturing defects; includes pre-shipment functional test report

Retrofit Planning for Existing Automation Systems

A successful retrofit of the ACQ580-01-07A2-4 into an existing pump or fan control system begins well before the drive arrives on site. Start by auditing the control cabinet: confirm that the existing 24 V DC auxiliary power supply (typically an ABB CP-D 24/1.3 or equivalent) can sustain the drive’s control board and any connected I/O modules without voltage droop. If the cabinet also houses an ACQ580-01-012A-4 or ACQ580-01-017A-4 for a parallel pump duty, verify that the shared DC bus or common supply rail is rated for the combined inrush current during simultaneous start sequences.

Terminal wiring is the most time-sensitive step. The ACQ580-01-07A2-4 uses the standard ACQ580 X1 analog input block (AI1 for 4–20 mA pressure transmitter feedback, AI2 for external setpoint) and the X2 digital input block (DI1–DI6 for start/stop, fault reset, and speed reference selection). If the original drive was fitted with an FAIO-01 analog I/O extension module or an FDIO-01 digital I/O extension module, these can be re-mounted on the new drive’s option slot without rewiring field cables. Similarly, if a FENA-21 EtherNet/IP adapter or FPBA-01 PROFIBUS-DP adapter was installed on the legacy unit, it transfers directly to the replacement drive — simply re-enter the node address and baud rate in parameter group 58 (Embedded Fieldbus) or the adapter’s own parameter set.

For sites running an ABB AC500 PLC (such as a PM573 or PM591 CPU) as the supervisory controller, the drive’s Modbus RTU link to the PLC’s CM572-DP or TK501 communication module should be re-verified after parameter restore. Confirm that the holding register map (speed reference at 40002, output frequency at 30002, fault word at 30005) matches the PLC’s existing function block configuration. If the site uses an ABB CP600 HMI panel for operator interface, the drive’s process variable scaling (parameter 46.01–46.03) must match the HMI’s tag database to avoid incorrect speed or pressure readouts on the operator screen.

Backplane and rack considerations apply when the ACQ580 is installed in a multi-drive cabinet alongside an ACS880 regenerative supply unit or a common DC bus system. Confirm that the DC link capacitor pre-charge sequence is not disrupted by the new drive’s power-up timing. For standalone installations, a standard ABB JOKAB Safety relay or a Pilz PNOZ X series safety relay in the STO (Safe Torque Off) circuit should be re-tested after drive replacement to confirm STO response time remains within the machine’s safety function requirements.

Downtime Control During System Migration

Minimizing production downtime during an ACQ580-01-07A2-4 swap requires a structured pre-outage preparation protocol. Before the maintenance window opens, use ABB Drive Composer Entry (free download) connected via the drive’s USB service port or the ACS-AP-I control panel to export the complete parameter backup file (.dcp format) from the faulted or end-of-life drive. Store this file on a USB drive and on a network share. If the original drive is already non-functional, cross-reference the site’s commissioning record or the PLC program’s drive parameter initialization block to reconstruct the critical parameters: motor nominal values (group 99), application macro selection (group 96.04), PID setpoint source (group 40), and fieldbus communication settings (group 58).

During the outage, follow a strict sequence: isolate and lock out the incoming 480 V supply, discharge the DC bus (minimum 5 minutes after isolation), remove the legacy drive, mount the ACQ580-01-07A2-4 on the existing DIN rail or panel back-plate, reconnect power terminals (U1/V1/W1 input, U2/V2/W2 motor output), reconnect control terminals in order (PE ground first, then 24 V auxiliary, then signal wiring), and re-seat any fieldbus adapter. After power-up, restore the parameter backup file, run the motor identification routine (ID run — parameter 99.13 set to 2 for standard ID run), and verify output frequency and current readings against the motor nameplate before releasing the drive to automatic control.

For critical continuous-process applications — water supply stations, cooling tower fans, or wastewater lift pumps — consider pre-staging the replacement ACQ580-01-07A2-4 with parameters already loaded and tested on a bench power supply before the maintenance window. This reduces in-cabinet commissioning time to under 30 minutes and protects the original program logic from on-site parameter entry errors. SMARTNEXMSK can supply pre-configured units with customer-specified parameter files loaded at dispatch upon request.

Retrofit Support FAQ

Q1: Is the ACQ580-01-07A2-4 a direct drop-in replacement for my existing ACQ580-01-07A2-4 without any wiring changes?
Yes. The ACQ580-01-07A2-4 uses the identical R1 frame dimensions, terminal block layout, and mounting hole pattern as the original production unit. Existing power cables, control signal wiring, and any installed fieldbus adapter (FENA-21, FPBA-01, FCAN-01, etc.) can be transferred without modification. The only required post-installation steps are parameter restore and motor ID run.

Q2: Can I use my existing ACS-AP-I or ACS-AP-W control panel for commissioning?
Yes. The ACQ580-01-07A2-4 is fully compatible with the ACS-AP-I (intelligent) and ACS-AP-W (HVAC/pump) assistant control panels via the standard panel bus connector. ABB Drive Composer Entry and Pro software are also supported via the USB service port. No additional programming cables or adapters are required if you already have these tools on site.

Q3: What should I verify regarding communication compatibility before replacing the drive in a Modbus RTU or PROFIBUS network?
After parameter restore, navigate to parameter group 58 (Embedded Fieldbus — Modbus RTU) and confirm the node address, baud rate (typically 19200 or 38400 bps), and parity settings match the PLC’s communication configuration. For PROFIBUS-DP via FPBA-01 adapter, re-enter the DP node address in the adapter’s parameter set and verify the GSD file version in the PLC’s hardware configuration matches the adapter firmware. Perform a communication link test (monitor parameter 58.06 — received packets counter) before releasing the drive to automatic mode.

Q4: What does the 12-month warranty cover, and what pre-shipment testing is performed?
Every ACQ580-01-07A2-4 supplied by SMARTNEXMSK undergoes pre-shipment functional testing: input/output voltage verification at rated load, parameter default restore and re-save, control terminal I/O continuity check, and communication port handshake test. The 12-month warranty covers manufacturing defects in materials and workmanship from the date of shipment. A test record is available upon request. Warranty claims are processed with a replacement-first policy to minimize your system downtime.