ABB KRAFT-DC2 Retrofit-Ready DC Drive Control Board: Compatible Modernization & Smooth Legacy System Upgrade
The ABB KRAFT-DC2 is a DC drive control board engineered for seamless integration into existing ABB KRAFT Series drive systems. Whether you are replacing a failed unit on an aging production line, upgrading a discontinued control platform, or modernizing a legacy control cabinet, the KRAFT-DC2 delivers verified electrical compatibility, reliable signal handling, and the performance consistency that industrial retrofit projects demand.
In today’s manufacturing environment, unplanned downtime caused by obsolete or discontinued drive components is one of the most costly disruptions a facility can face. The KRAFT-DC2 is stocked specifically to address this challenge — providing a direct-fit replacement that eliminates the need for full drive replacement, costly rewiring, or extended commissioning cycles. Each unit is pre-tested prior to shipment and backed by a 12-month warranty, giving your maintenance team confidence from the moment it arrives on site.
Upgrade Compatibility Table
| Parameter | Details |
|---|---|
| Compatible Series | ABB KRAFT Series DC Drives |
| Replaces / Upgrades | KRAFT-DC1, KRAFT-DC2 (original), legacy KRAFT drive control boards |
| Backplane Interface | Standard KRAFT Series backplane connector; verify slot position before installation |
| Communication Compatibility | Supports existing fieldbus wiring; confirm protocol (Profibus, Modbus RTU, or hardwired I/O) with site documentation |
| Power Supply Requirement | Verify control power rail capacity before installation; consult drive cabinet power budget |
| Terminal Wiring | Terminal layout matches KRAFT Series standard; cross-reference original wiring diagram |
| Module Address | Set via DIP switch or parameter configuration; confirm address map with existing PLC program |
| Installation Requirement | DIN rail or panel mount; follow KRAFT Series mechanical installation guide |
| Commissioning Focus | Speed reference signal, current limit parameters, encoder feedback (if applicable), and fault reset logic |
| Warranty | 12 months from date of shipment; covers manufacturing defects and functional failure |
Retrofit Planning for Existing Automation Systems
A successful KRAFT-DC2 retrofit begins well before the replacement board arrives on site. The first step is a thorough audit of the existing control cabinet — documenting the current ABB KRAFT Series drive configuration, the control power supply capacity, and the I/O wiring layout. In many legacy installations, the drive control board interfaces directly with a programmable logic controller (PLC) via hardwired analog or digital I/O, or through a fieldbus adapter such as an ABB RDNA-01 DeviceNet adapter or RPBA-01 Profibus adapter. Confirming which communication path is active — and whether the existing fieldbus cable and termination resistors are in good condition — is essential before powering up the replacement board.
Terminal wiring is another critical checkpoint. The KRAFT-DC2 uses the standard KRAFT Series terminal block layout, but aging installations may have non-standard field modifications. Before removing the original board, photograph or document every terminal connection, including shielding and grounding points. Pay particular attention to the speed reference input (typically 0–10 V or 4–20 mA), the enable/run signal, and any fault relay outputs wired to the upstream safety relay module or emergency stop circuit.
For sites running a SIMATIC S7-300 or S7-400 PLC as the supervisory controller, verify that the drive’s parameter block in the PLC program still maps correctly to the new board’s register addresses. If the original drive was configured with a DriveWindow or Drive Composer parameter file, upload a backup before removal — this file will be the baseline for commissioning the KRAFT-DC2 and will save significant time during parameter restoration.
In multi-drive cabinets, the KRAFT-DC2 replacement may sit alongside other components such as an ABB ACS800 inverter module, a NDIO-02 digital I/O extension module, or a NTAC-02 pulse encoder interface module. Confirm that the backplane power budget accommodates the new board without overloading the NPOW-41 power supply module or equivalent cabinet power rail. If the cabinet also houses an ABB Panel Builder 800 HMI or a third-party operator panel, verify that the HMI tag database still references the correct drive parameters after the board swap — screen updates may be required if parameter addresses have shifted.
Finally, for sites migrating from an older KRAFT drive platform to a more modern ABB drive ecosystem, the KRAFT-DC2 can serve as an interim solution while a full migration to an ABB DCS880 or DCS550 DC drive platform is planned. This phased approach allows production to continue uninterrupted while the engineering team prepares the new drive program, I/O mapping, and HMI screens for the eventual full upgrade.
Downtime Control During System Migration
Minimizing downtime during a DC drive control board replacement requires a structured, pre-planned approach. Before the maintenance window opens, ensure the KRAFT-DC2 replacement board has been bench-tested with a known-good power supply and that all parameter files, wiring diagrams, and commissioning checklists are printed and available on site — do not rely on network access during the outage.
During the swap, work systematically: isolate the drive from the control power bus, discharge any residual voltage on the DC link capacitors, and remove the original board following the KRAFT Series mechanical guide. Install the KRAFT-DC2, reconnect all terminals in sequence using the pre-documented wiring photograph, and restore the parameter file via the drive’s serial commissioning port or keypad. If the drive communicates via Profibus or Modbus RTU, confirm the fieldbus node address and baud rate match the PLC configuration before enabling the drive.
For critical production lines where even a brief interruption is unacceptable, consider a parallel commissioning approach: install and configure the KRAFT-DC2 on a spare drive chassis in the workshop, verify all parameters and I/O responses against the original drive’s behavior, and then perform the live swap as a pre-tested, plug-in exchange. This approach can reduce live commissioning time to under 30 minutes in most cases, protecting both production continuity and the integrity of the original PLC program logic.
After the swap, run the drive through its full speed range under no-load conditions before reconnecting the mechanical load. Monitor current feedback, speed reference tracking, and fault relay status during the initial run. Document the commissioning results and update the site’s maintenance records with the new board’s serial number and installation date.
Retrofit Support FAQ
Q: Is the KRAFT-DC2 a direct drop-in replacement for the original ABB KRAFT Series control board?
A: Yes, the KRAFT-DC2 is designed as a direct replacement for the original KRAFT Series DC drive control board. Terminal layout, backplane connector, and parameter structure are compatible with the existing KRAFT Series drive chassis. Minor parameter adjustments may be required during commissioning to match the original drive’s tuning.
Q: What wiring checks should I perform before installing the KRAFT-DC2?
A: Before installation, verify the control power supply voltage and current capacity, document all terminal connections (speed reference, enable signal, fault relay, and fieldbus wiring), and confirm the grounding and shielding arrangement. Cross-reference the original wiring diagram and photograph the existing terminal block before removing the old board.
Q: How do I confirm communication compatibility with my existing PLC or fieldbus network?
A: Identify the active communication path — hardwired I/O, Profibus, Modbus RTU, or DeviceNet — and confirm the node address, baud rate, and termination settings match the PLC program configuration. If a fieldbus adapter module is installed on the drive, verify it is compatible with the KRAFT-DC2 and that the adapter firmware version is current.
Q: What does the 12-month warranty cover, and how is it processed?
A: The 12-month warranty covers manufacturing defects and functional failure under normal operating conditions from the date of shipment. If a warranty claim is required, contact our sales team at [email protected] with the order number, board serial number, and a description of the fault. Replacement or repair will be arranged promptly to minimize your downtime.
© 2026 SMARTNEXMSK. All rights reserved.
Original Source: https://smartnexmsk.com
Contact: [email protected] | +86 18259474341