Automation Part • SmartNexMSK Catalog

ABB SNAT0100-6B Retrofit-Ready Power Supply for ACS800

ABB SNAT0100-6B retrofit-ready power supply for ACS800 drives. Drop-in replacement, verified compatibility, 12-month warranty. Ships from stock.

SKU / Model SNAT0100-6B SNAT 0100-6B 61054588 5761852-3B
Brand ABB
Product Type Drive Power Supply Board
Series S800
Country of Origin SE
Catalog Category Business & Industrial > Automation, Control & Flow Devices > Industrial Control Systems > Variable Frequency Drives
Model checkSKU and compatibility Quality evidencePhotos on request Export supportPacking and delivery
Description

ABB SNAT0100-6B Retrofit-Ready Power Supply for ACS800 Overview

ABB SNAT0100-6B Retrofit-Ready Power Supply for ACS800 Control Systems

The ABB SNAT0100-6B is a drive power supply board engineered for the ACS800 series variable frequency drive platform — one of ABB’s most widely deployed industrial drive families across manufacturing, process automation, and heavy-duty motor control applications. As the ACS800 series enters its extended lifecycle phase and original spare parts become increasingly difficult to source through standard distribution channels, the SNAT0100-6B has become a critical retrofit and replacement component for maintenance engineers managing aging drive cabinets.

This board serves as the internal power supply unit responsible for generating the regulated DC voltages required by the ACS800 control electronics, gate driver circuits, and I/O interface boards. When the SNAT0100-6B fails, the drive typically enters a fault state — commonly displaying fault codes F-0001 (overcurrent), F-0002 (DC bus overvoltage), or supply-related hardware faults — rendering the entire drive inoperable until the board is replaced. Sourcing a verified replacement quickly is essential to minimizing unplanned downtime on production lines.

Our SNAT0100-6B units are sourced from controlled inventory channels, individually inspected prior to dispatch, and shipped with a 12-month warranty covering manufacturing defects and functional failures under normal operating conditions.

Upgrade Compatibility Table

Parameter Details
Compatible Drive Series ABB ACS800 (all frame sizes using SNAT0100-6B supply board)
Replaces / Supersedes SNAT0100-6B, 61054588, 5761852-3B (alternate part references)
Mounting / Installation Direct backplane mount; standard ACS800 drive cabinet rail fit
Connector Interface Multi-pin ribbon and discrete terminal connectors; verify harness routing before installation
Communication Compatibility Compatible with RDCO-02/03 (DriveWindow Link), RPBA-01 (PROFIBUS), RCAN-01 (CANopen) adapter boards
Firmware / Program Logic No firmware stored on power supply board; drive application program retained in RMIO control board
Replacement Recommendation Direct drop-in replacement; no parameter changes required for power supply swap
Commissioning Note Perform insulation resistance check and DC bus pre-charge verification after installation
Warranty 12 months from date of shipment; covers manufacturing defects and functional failure

Retrofit Planning for Existing Automation Systems

Replacing the SNAT0100-6B in an operational ACS800 drive cabinet requires careful pre-work to ensure a smooth cutover. Before removing the faulty board, engineers should document the existing wiring harness routing, photograph connector positions, and verify that the RMIO-11C or RMIO-02C main control board — which retains the drive’s application parameters and motor control program — is undamaged and will not require re-commissioning after the power supply swap.

In retrofit projects where the ACS800 is being integrated into a modernized control architecture, the SNAT0100-6B replacement is often performed alongside upgrades to the I/O interface layer. Common companion components in these projects include the RAIO-01 analog I/O extension module, the RDIO-01 digital I/O extension board, and the RTAC-01 pulse encoder interface module — all of which mount to the RMIO board’s option slots and remain unaffected by the power supply replacement. If the retrofit also involves migrating from a legacy fieldbus to a modern Ethernet-based protocol, the RENA-01 Ethernet adapter or RPBA-01 PROFIBUS-DP adapter may be installed concurrently, taking advantage of the drive downtime window.

For sites running multiple ACS800 units in a common DC bus configuration, the SNAT0100-6B replacement must be coordinated with the inverter unit schedule to avoid disrupting the shared DC link. In these architectures, the AINT-02 or AINT-14 inverter control boards and the associated APOW-01 auxiliary power supply units in the inverter modules should be inspected at the same time, as power supply degradation in one unit often indicates thermal stress across the entire drive line-up.

Panel builders and system integrators performing full control cabinet upgrades frequently replace the SNAT0100-6B as part of a broader ACS800 refurbishment that includes new capacitor banks, updated cooling fans, and replacement of the JCU-01 or JCU-02 junction control units used in multi-drive configurations. Having the SNAT0100-6B in stock before the maintenance window opens is essential — a single missing component can extend a planned 4-hour outage into a multi-day production stoppage.

For HMI-connected installations, verify that the Panel Bus or DriveWindow Light communication link between the ACS800 and the operator panel (such as the CDP312R or ACS-CP-C control panel) remains functional after the power supply replacement. The control panel retains its parameter set independently, but the communication link should be tested before returning the drive to automatic mode.

Downtime Control During System Migration

Minimizing downtime during an ACS800 power supply replacement begins with advance preparation. Before the maintenance window, use DriveWindow Light or DriveWindow 2 software to perform a full parameter backup of the RMIO control board via the RDCO-02 DriveWindow Link adapter. This backup preserves the complete motor control program, speed reference scaling, PID tuning parameters, and all fieldbus node address settings — ensuring that if the RMIO board requires any intervention during the swap, the drive can be restored to its exact pre-fault configuration within minutes.

During the physical replacement, follow ABB’s lockout/tagout procedure for the ACS800 frame size in use, discharge the DC bus capacitors fully (typically 5 minutes after main power isolation), and verify zero voltage on the DC bus terminals before touching any internal components. The SNAT0100-6B can then be removed by disconnecting its ribbon cable harnesses and sliding the board from its backplane guides.

After installing the replacement SNAT0100-6B, perform a controlled power-up sequence: apply auxiliary 24 VDC control power first (if the drive uses a separate APOW supply), verify that the RMIO board initializes correctly and displays the expected parameter set on the CDP312R panel, then apply main AC power and monitor the DC bus charge curve. Run the drive in local control mode at low speed before returning it to remote/fieldbus control to confirm that all I/O signals, speed references, and fault relay outputs are functioning correctly. This staged commissioning approach typically allows a full ACS800 power supply replacement to be completed within a 2–4 hour maintenance window, preserving production continuity on adjacent lines throughout the process.

Retrofit Support FAQ

Q: Is the SNAT0100-6B a direct replacement for all ACS800 frame sizes?
A: The SNAT0100-6B is used across multiple ACS800 frame sizes, but you should verify the exact part number against your drive’s nameplate and internal label before ordering. The alternate references 61054588 and 5761852-3B refer to the same board under different ABB catalog numbering conventions. Contact us with your drive’s serial number if you need confirmation.

Q: Will replacing the SNAT0100-6B erase my drive’s parameters or application program?
A: No. The application program and all parameters are stored on the RMIO control board, not on the power supply board. A SNAT0100-6B replacement does not affect the drive’s parameter set. However, we always recommend performing a parameter backup via DriveWindow before any internal maintenance as a precaution.

Q: What wiring checks should I perform before installing the replacement board?
A: Inspect all ribbon cable connectors and discrete wiring harnesses that attach to the SNAT0100-6B for signs of heat damage, pin corrosion, or insulation breakdown. A failed power supply board can sometimes cause secondary damage to connected harnesses. Verify connector seating and locking tab engagement after installation, and check that no cables are pinched during reassembly.

Q: What does the 12-month warranty cover?
A: Our 12-month warranty covers manufacturing defects and functional failures under normal operating conditions from the date of shipment. Each unit undergoes pre-shipment functional inspection. Warranty claims are supported by our technical team — contact [email protected] with your order reference and fault description for rapid resolution.

© 2026 SMARTNEXMSK. All rights reserved.
Original Source: https://smartnexmsk.com
Contact: [email protected] | +86 18259474341

Catalog Paths

Continue from this exact model

Use the live catalog paths below to compare the same brand, product type, or series before sending your RFQ.

RFQ Intent Desk

Choose the right sourcing path for this model

Each action carries the product model and intent into the inquiry record so the sales follow-up starts with useful context.

Exact Model Quote

Use this path when the SKU, brand, quantity, and destination are already confirmed.

Start
Replacement Check

Use this path for old, obsolete, or uncertain models that need compatibility review.

Start
Quality Confirmation

Ask for label photos, packing notes, documentation, or pre-shipment checks.

Start
Urgent Dispatch

Route downtime or maintenance requests with target dispatch timing and courier country.

Start
Request Quote WhatsApp Email