Bently Nevada 330800-28-00-085-02-02 Retrofit-Ready Proximity Transducer for 3300 Series Control Systems
The Bently Nevada 330800-28-00-085-02-02 is a PROXPAC XL proximity transducer assembly engineered for direct retrofit into existing Bently Nevada 3300 series vibration monitoring systems. As legacy machinery protection infrastructure ages and OEM support windows close, this assembly provides a verified drop-in replacement path that preserves existing wiring, rack architecture, and software configuration — minimizing engineering rework and unplanned downtime during critical system transitions.
This unit is fully compatible with the Bently Nevada 3300 XL series monitor rack, including the 3300/16 and 3300/20 dual-channel vibration monitors. It operates on the standard Bently Nevada eddy-current sensing principle, delivering a linear output of -18 VDC at the standard 200 mV/mil (7.87 V/mm) sensitivity, consistent with the original PROXPAC XL specification. The assembly integrates the proximitor, extension cable, and probe into a single pre-calibrated unit, eliminating field calibration steps and reducing commissioning time on retrofit projects.
Upgrade Compatibility Table
| Parameter | Detail |
|---|---|
| SKU / Part Number | 330800-28-00-085-02-02 |
| Brand | Bently Nevada |
| Series Compatibility | 3300 XL Series (3300/16, 3300/20, 3300/25, 3300/46, 3300/55) |
| Assembly Type | PROXPAC XL (Probe + Extension Cable + Proximitor) |
| Output Sensitivity | 200 mV/mil (7.87 V/mm) |
| Supply Voltage | -24 VDC nominal (range: -18 to -26 VDC) |
| Probe Tip Diameter | 8 mm |
| Extension Cable Length | 2.8 m (standard) |
| Connector Interface | Standard BNC / Bently Nevada 3-pin terminal |
| Installation Requirement | Direct replacement — no bracket modification required for standard 3300 rack |
| Communication Compatibility | Analog 4–20 mA / direct monitor input; compatible with System 1 software |
| Replacement Recommendation | Replaces discontinued 330800-28-00 series variants; verify gap voltage at commissioning |
| Commissioning Note | Set air gap to 1.0 mm (40 mil); verify -10 VDC ±0.5 V output at nominal gap |
| Warranty | 12 Months — covers manufacturing defects and functional failure under normal operating conditions |
Retrofit Planning for Existing Automation Systems
Successful integration of the 330800-28-00-085-02-02 into a legacy machinery protection system requires a structured pre-installation review. Engineers should begin by auditing the existing 3300 XL monitor rack configuration, confirming that the installed 3300/16 or 3300/20 dual-channel vibration monitor is set to accept the standard PROXPAC XL input range. Where the rack also houses a 3300/46 thrust position monitor or a 3300/55 speed monitor, verify that the shared -24 VDC power bus has sufficient current headroom to support the replacement assembly without voltage droop.
Terminal wiring on the 3300 series barrier terminal strip follows the standard Bently Nevada color-coded scheme: the proximitor output (white) connects to the monitor input terminal, the shield (drain) connects to the chassis ground lug, and the -24 VDC supply (red) feeds from the rack’s internal power distribution. If the existing installation uses a 3300/05 power supply module, confirm that the output current rating accommodates the full channel load after replacement. In racks where a 3300/25 keyphasor module is installed, the replacement transducer’s gap voltage must be re-verified to ensure the keyphasor trigger threshold remains within the configured window.
For systems that have been extended with a 3500 series migration path, the 330800-28-00-085-02-02 can serve as an interim transducer while the monitoring infrastructure is upgraded to the Bently Nevada 3500/42M or 3500/45 position monitor. During this transitional phase, the existing System 1 software configuration can be retained without modification, as the output signal format is electrically identical. Engineers migrating from older 7200 series proximitors should note that the PROXPAC XL assembly uses a different connector pinout and will require a short adapter harness at the monitor input terminal.
I/O expansion projects that add a 3300/46 thrust monitor or a 3300/55 overspeed detection module to an existing rack should be completed before the transducer replacement to avoid multiple rack power interruptions. Where a Bently Nevada 1900/65A general-purpose vibration transmitter is used as a remote signal conditioner, confirm that the 4–20 mA output scaling matches the DCS input card range before finalizing the loop configuration.
Downtime Control During System Migration
Minimizing production interruption during a proximity transducer replacement requires a disciplined pre-outage preparation protocol. Before the planned maintenance window, download and archive the current System 1 database configuration, including all alarm setpoints, gap voltage baselines, and trend history for the affected measurement points. This ensures that if the replacement commissioning reveals an unexpected sensitivity deviation, the original configuration can be restored without re-engineering.
Where the process cannot tolerate a full machinery shutdown, consider a staged replacement approach: install the 330800-28-00-085-02-02 on a non-critical measurement channel first, verify gap voltage and output linearity under live conditions, then proceed to the primary radial vibration channel during the next scheduled outage. This approach is particularly effective in compressor trains where the 3300/16 monitor covers both X and Y radial channels — replacing one channel at a time allows the protection system to remain partially active throughout the migration.
After physical installation, the commissioning sequence should follow the standard Bently Nevada gap-setting procedure: position the probe tip at the nominal 1.0 mm air gap, confirm the proximitor output reads -10 VDC ±0.5 V, then lock the probe in position and re-torque the locknut to the specified value. Re-enter the gap voltage baseline in System 1 and perform a channel functional test by simulating a high-vibration condition using a calibrated shaker or by manually deflecting the probe. Confirm that the 3300 monitor relay output responds correctly before returning the machinery to service. All units supplied by SMARTNEXMSK are pre-tested prior to shipment to reduce on-site commissioning risk.
Retrofit Support FAQ
Q: Is the 330800-28-00-085-02-02 a direct drop-in replacement for the original 330800-28-00 series?
A: Yes. The 330800-28-00-085-02-02 is dimensionally and electrically compatible with the standard 330800-28-00 PROXPAC XL family. The probe tip diameter, extension cable length, connector interface, and output sensitivity are identical to the original specification. No bracket modification or wiring change is required for installations in a standard 3300 XL rack.
Q: What commissioning checks are required after installation?
A: Set the probe air gap to 1.0 mm (40 mil) and verify the proximitor output reads -10 VDC ±0.5 V. Confirm the gap voltage baseline in System 1, perform a channel functional test, and verify that all alarm and danger relay outputs respond correctly. For installations adjacent to a 3300/25 keyphasor module, re-verify the trigger threshold after gap setting.
Q: Can this unit be used in a 3500 series rack as part of a migration project?
A: The 330800-28-00-085-02-02 is designed for the 3300 XL series rack architecture. For 3500 series racks, Bently Nevada specifies dedicated transducer assemblies matched to the 3500/42M or 3500/45 monitor input requirements. This unit can serve as an interim replacement during a phased migration but should be replaced with the appropriate 3500-compatible assembly before final system handover.
Q: What does the 12-month warranty cover?
A: The 12-month warranty covers manufacturing defects and functional failure under normal operating conditions from the date of shipment. Units that fail functional pre-shipment testing are replaced before dispatch. Warranty claims are supported by SMARTNEXMSK’s technical team; contact [email protected] with the order reference and a description of the observed fault.
© 2026 SMARTNEXMSK. All rights reserved.