BUCHI V-700 0800011508 Retrofit-Ready Vacuum Pump

BUCHI V-700 0800011508 retrofit-ready diaphragm vacuum pump. Compatible with Rotavapor R-100, R-200, R-300. Oil-free, 2 mbar, 12-month warranty, in stock.

SKU0800011508 V-700 1127-452-02 27220C BTS10-2,5/8-24-RL-720
BrandBUCHI
SeriesOther series
BUCHI 0800011508 V-700 1127-452-02 27220C BTS10-2,5/8-24-RL-720 Diaphragm Vacuum Pump
Model context is attached to every quote action. Use WhatsApp for urgent downtime, or Email for purchasing records.
Model checkSKU and compatibility review Quality evidencePhotos and label notes when available Export supportPacking, courier, and delivery notes
Product Information

Model Details

SKU / Model 0800011508 V-700 1127-452-02 27220C BTS10-2,5/8-24-RL-720
Brand BUCHI
Product Type Diaphragm Vacuum Pump
Series Other series
Catalog Category Business & Industrial > Automation, Control & Flow Devices
Tags 0800011508, 12-month-warranty, BUCHI, diaphragm-vacuum-pump, discontinued-replacement, in-stock, lab-vacuum, oil-free-vacuum, R-100, R-200, R-300, replacement, retrofit, rotavapor-compatible, V-700
Catalog Paths

Continue from this exact model

Use the live catalog paths below to compare the same brand, product type, or series before sending your RFQ.

RFQ Intent Desk

Choose the right sourcing path for this model

Each action carries the product model and intent into the inquiry record so the sales follow-up starts with useful context.

Exact Model Quote

Use this path when the SKU, brand, quantity, and destination are already confirmed.

Start
Replacement Check

Use this path for old, obsolete, or uncertain models that need compatibility review.

Start
Quality Confirmation

Ask for label photos, packing notes, documentation, or pre-shipment checks.

Start
Urgent Dispatch

Route downtime or maintenance requests with target dispatch timing and courier country.

Start
Description

BUCHI V-700 0800011508 Retrofit-Ready Vacuum Pump Overview

BUCHI V-700 0800011508 Retrofit-Ready Diaphragm Vacuum Pump for Legacy Rotavapor Control Systems

The BUCHI V-700 (Part No. 0800011508) is a chemically resistant, oil-free diaphragm vacuum pump engineered for seamless integration into existing laboratory vacuum and evaporation systems. As a retrofit-ready replacement unit, the V-700 is the preferred upgrade path for facilities operating legacy BUCHI Rotavapor platforms — including the R-100, R-200, and R-300 series — where the original vacuum source has reached end-of-life, been discontinued, or no longer meets process performance requirements.

With an ultimate vacuum of 2 mbar and a pumping speed of 1.5 m³/h, the V-700 delivers consistent, pulse-free vacuum suitable for rotary evaporation, filtration, drying, and concentration workflows. Its PTFE-coated diaphragm and valve construction ensure full chemical resistance against aggressive solvents including acetone, ethanol, dichloromethane, and toluene — making it a direct functional replacement for earlier BUCHI vacuum modules and third-party oil-sealed pumps previously installed in the same control cabinet or bench configuration.

Upgrade Compatibility Table

Parameter Detail
Part Number 0800011508
Model BUCHI V-700
Compatible Systems Rotavapor R-100, R-200, R-300; BUCHI Interface I-300 Pro; V-Control vacuum controller
Replaces / Upgrades From V-500, V-600, V-710 (discontinued); legacy oil-sealed vacuum pumps in same bench setup
Ultimate Vacuum 2 mbar (absolute)
Pumping Speed 1.5 m³/h
Power Supply 100–240 V AC, 50/60 Hz (universal input)
Connection Interface Standard hose barb fittings; compatible with BUCHI vacuum tubing and V-Control RS-232 port
Communication Compatibility Analog vacuum signal; RS-232 interface for V-Control / I-300 Pro integration
Installation Requirement Bench-top or rack-adjacent; no special mounting bracket required for standard Rotavapor setups
Retrofit Commissioning Verify vacuum line integrity, re-zero V-Control setpoint, confirm solvent trap connection
Warranty 12 Months — covers diaphragm, valves, motor, and electrical components

Retrofit Planning for Existing Automation Systems

When integrating the BUCHI V-700 0800011508 into an existing laboratory automation or evaporation system, a structured retrofit plan is essential to ensure process continuity and minimize disruption. The V-700 is designed to slot into the same vacuum circuit previously served by the V-500 or V-600 series, but several verification steps must be completed before commissioning.

Begin by auditing the existing vacuum line layout. Confirm that the inlet and outlet hose barb diameters match the V-700’s standard fittings, and inspect the solvent trap — typically a BUCHI V-800 or equivalent cold trap — for condition and seal integrity. If the trap has been in service for more than two years, replacement of the O-ring kit is recommended before connecting the new pump. The vacuum tubing connecting the pump to the Rotavapor R-200 or R-300 evaporator flask should be inspected for micro-cracks, particularly at the rotary joint and condenser inlet, as any leak will prevent the V-700 from reaching its rated 2 mbar ultimate vacuum.

For systems using the BUCHI Interface I-300 Pro or the V-Control vacuum controller, the RS-232 communication link between the pump and controller must be re-established after hardware swap. The V-Control unit stores vacuum setpoints and ramp profiles in non-volatile memory, so existing process recipes are preserved across the pump replacement — however, the vacuum setpoint should be re-verified against the new pump’s performance curve during the first commissioning run. If the facility previously used a third-party vacuum controller or a manual needle valve for vacuum regulation, upgrading to the V-Control at the same time as the V-700 installation is strongly recommended to enable closed-loop vacuum management.

Power supply compatibility is straightforward: the V-700 accepts 100–240 V AC at 50/60 Hz, making it suitable for both domestic and international laboratory environments without a step-down transformer. Confirm that the local power outlet or PDU (power distribution unit) in the control cabinet can supply at least 230 W continuously. In multi-pump configurations — for example, where a single vacuum manifold serves both a Rotavapor R-300 and a parallel filtration station — ensure that the manifold’s total load does not exceed the V-700’s rated pumping capacity, and consider adding a BUCHI vacuum valve or solenoid isolation valve to segment the circuit.

For facilities running the BUCHI Syncore or Multivapor parallel evaporation platforms alongside a Rotavapor, note that the V-700 is not rated for simultaneous multi-instrument vacuum supply without a buffer vessel. A vacuum buffer flask (1–2 L borosilicate) inserted between the pump outlet and the manifold will stabilize vacuum delivery and extend diaphragm service life. The pump’s exhaust should be routed to the facility’s solvent exhaust duct or a dedicated activated carbon filter to comply with laboratory ventilation requirements.

Downtime Control During System Migration

Minimizing unplanned downtime during a vacuum pump replacement is a primary concern for any production or research laboratory. The BUCHI V-700 0800011508 is shipped fully assembled and factory-tested, which eliminates on-site break-in time and allows same-day recommissioning in most retrofit scenarios.

The recommended migration sequence is as follows: First, complete all active evaporation runs and allow the existing pump to cool. Vent the vacuum circuit to atmosphere via the Rotavapor’s vent valve before disconnecting any fittings. Label all vacuum hose connections before removal to ensure correct reassembly. The V-700 can be physically installed and connected in under 30 minutes for a standard single-instrument setup. Once connected, power on the pump and allow a 5-minute warm-up period before engaging the V-Control or I-300 Pro vacuum regulation. Run a blank evaporation cycle (no solvent, flask sealed) to verify that the system reaches the target vacuum setpoint within the expected time — typically under 3 minutes for a clean, leak-free circuit.

If the facility cannot tolerate any process interruption, a parallel commissioning approach is possible: install the V-700 on a secondary vacuum line and validate its performance before switching over the primary circuit. This approach is particularly valuable in GMP or regulated laboratory environments where process validation documentation is required. All units supplied by SMARTNEXMSK are pre-tested and include a factory test report confirming ultimate vacuum performance, diaphragm integrity, and electrical safety compliance — supporting your internal qualification documentation.

Original program logic stored in the V-Control or I-300 Pro is not affected by the pump swap, as these controllers store setpoints independently of the pump hardware. HMI screens on connected BUCHI systems will continue to display vacuum readings without reconfiguration, provided the RS-232 communication cable is reconnected to the same port on the new V-700 unit.

Retrofit Support FAQ

Q1: Is the BUCHI V-700 0800011508 a direct drop-in replacement for the V-500 and V-600?
A: Yes, for the majority of Rotavapor R-100, R-200, and R-300 installations. The V-700 uses the same hose barb connection standard and is compatible with the V-Control RS-232 interface. The primary difference is improved ultimate vacuum (2 mbar vs. 5–7 mbar on the V-500/V-600) and a longer diaphragm service interval. No mechanical adapter or wiring modification is required in standard configurations.

Q2: What wiring and connection checks are required before commissioning?
A: Verify the power cable is correctly rated for local voltage (100–240 V AC). Inspect the RS-232 cable between the V-700 and V-Control or I-300 Pro for pin continuity. Confirm all vacuum hose connections are fully seated and clipped. Check the solvent trap for liquid accumulation and empty if necessary before starting the pump. A leak test at 10 mbar is recommended before running the first process batch.

Q3: How do I confirm compatibility with my existing V-Control vacuum controller?
A: The V-700 is natively compatible with all versions of the BUCHI V-Control and Interface I-300 Pro. If your controller firmware is older than version 2.x, a firmware update may be required to enable full closed-loop vacuum regulation with the V-700. Contact SMARTNEXMSK with your V-Control serial number and we will confirm firmware compatibility before shipment.

Q4: What does the 12-month warranty cover, and what is the claims process?
A: The 12-month warranty covers all manufacturing defects in the diaphragm assembly, valve plates, motor, and electrical components under normal laboratory operating conditions. It does not cover damage caused by pumping liquid solvents directly (without a solvent trap), operation outside rated voltage, or physical impact. To initiate a warranty claim, contact sales@smartnexmsk.com with your order number, a description of the fault, and photos of the unit. Replacement or repair is typically completed within 10 business days of claim approval.


© 2026 SMARTNEXMSK. All rights reserved.
Original Source: https://smartnexmsk.com
Contact: sales@smartnexmsk.com | +86 18259474341