Automation Part SmartNexMSK Catalog

Cognex ISV2-01P-X Retrofit-Ready Vision Controller for In-Sight 2000

Cognex ISV2-01P-X (825-10567-1R) retrofit-ready replacement for In-Sight 2000 Series. Verified compatibility, 12-month warranty, fast global shipping.

SKUISV2-01P-X 825-10567-1R 821-10005-1R
BrandCognex
SeriesOther series
Cognex ISV2-01P-X 825-10567-1R 821-10005-1R Machine Vision Controller
Model context is attached to every quote action. Use WhatsApp for urgent downtime, or Email for purchasing records.
Model checkSKU and compatibility review Quality evidencePhotos and label notes when available Export supportPacking, courier, and delivery notes
Product Information

Model Details

SKU / Model ISV2-01P-X 825-10567-1R 821-10005-1R
Brand Cognex
Product Type Machine Vision Controller
Series Other series
Catalog Category Business & Industrial > Automation, Control & Flow Devices > Programmable Logic Controllers
Country of Origin US
Tags 825-10567-1R, Cognex, In-Sight 2000, ISV2-01P-X, Machine Vision, Replacement, Retrofit
Catalog Paths

Continue from this exact model

Use the live catalog paths below to compare the same brand, product type, or series before sending your RFQ.

RFQ Intent Desk

Choose the right sourcing path for this model

Each action carries the product model and intent into the inquiry record so the sales follow-up starts with useful context.

Exact Model Quote

Use this path when the SKU, brand, quantity, and destination are already confirmed.

Start
Replacement Check

Use this path for old, obsolete, or uncertain models that need compatibility review.

Start
Quality Confirmation

Ask for label photos, packing notes, documentation, or pre-shipment checks.

Start
Urgent Dispatch

Route downtime or maintenance requests with target dispatch timing and courier country.

Start
Description

Cognex ISV2-01P-X Retrofit-Ready Vision Controller for In-Sight 2000 Overview

Cognex ISV2-01P-X Retrofit-Ready Vision Controller for In-Sight 2000: Compatible Modernization & Smooth System Upgrade

The Cognex ISV2-01P-X (part numbers 825-10567-1R and 821-10005-1R) is a retrofit-ready machine vision controller designed as a direct functional replacement for legacy In-Sight 2000 Series vision systems. As production lines age and original Cognex In-Sight 2000 units reach end-of-life or become unavailable as spare parts, the ISV2-01P-X provides a verified upgrade path that preserves existing inspection logic, minimizes rewiring, and restores full vision-guided automation capability with minimal disruption to ongoing operations.

Industrial facilities running legacy vision-guided assembly, barcode reading, label verification, or dimensional inspection on In-Sight 2000 platforms face increasing risk from component obsolescence. The ISV2-01P-X addresses this directly: it maintains physical and electrical compatibility with standard In-Sight mounting hardware, accepts the same 24 VDC power input, and communicates over Ethernet using the native Cognex Native Mode and EasyBuilder protocol stack — meaning existing PLC ladder logic, HMI screen bindings, and SCADA data links can be preserved without reprogramming from scratch.

For engineers planning a controlled retrofit, the ISV2-01P-X integrates cleanly into control cabinets already housing Cognex In-Sight 2000 I/O expansion modules, In-Sight I/O cables (CCB-84901-x0xx series), and standard DIN-rail mounted 24 VDC power supplies. The unit’s discrete I/O lines — typically 8 digital inputs and 4 digital outputs — map directly to existing terminal block wiring, reducing the need for intermediate relay panels or signal converters during the changeover window.

Upgrade Compatibility Table

Parameter Legacy In-Sight 2000 ISV2-01P-X (825-10567-1R)
Power Supply 24 VDC ±10% 24 VDC ±10% — direct match
Communication Protocol Cognex Native Mode / EasyBuilder over Ethernet Cognex Native Mode / EasyBuilder — fully compatible
Discrete I/O 8 DI / 4 DO (opto-isolated) 8 DI / 4 DO — same terminal mapping
Mounting Standard In-Sight bracket / DIN adapter Compatible with existing In-Sight mounting hardware
Job File Compatibility In-Sight Explorer .job format Supports In-Sight Explorer job import with minor revision check
HMI Integration OPC, Modbus TCP, or proprietary string commands Same protocol support — HMI screens typically require no redesign
Commissioning Requirement Full calibration on install Re-run calibration routine; existing fixture positions reusable
Warranty OEM warranty expired (EOL unit) 12-Month Warranty from SMARTNEXMSK

Retrofit Planning for Existing Automation Systems

A successful ISV2-01P-X retrofit begins with a structured pre-installation audit. Before removing the legacy In-Sight 2000 unit, engineers should document the existing Ethernet IP address and subnet configuration, export all active job files from In-Sight Explorer, and photograph the terminal block wiring layout at the CCB-84901 I/O cable connector. This documentation becomes the baseline for post-swap verification.

Power capacity in the control cabinet must be confirmed before installation. The ISV2-01P-X draws up to 10 W at 24 VDC under full processing load. If the cabinet’s existing 24 VDC DIN-rail power supply (commonly a Phoenix Contact QUINT or Siemens SITOP unit) is already near capacity due to co-located Cognex In-Sight I/O expansion blocks or additional 24 VDC relay modules, a load calculation should be performed and a supplementary power rail considered before proceeding.

Backplane and rack considerations are minimal for this model — the ISV2-01P-X is a standalone vision controller, not a rack-mounted module, so there is no backplane slot address to configure. However, if the legacy system included a Cognex In-Sight 2000 Series trigger splitter or strobe controller for multi-camera synchronization, those accessories should be verified for compatibility with the replacement unit’s trigger input timing specifications.

For facilities where the In-Sight 2000 communicated with a Rockwell Automation ControlLogix or CompactLogix PLC via Ethernet/IP or Modbus TCP, the ISV2-01P-X maintains the same communication interface. The PLC’s existing MSG instruction blocks or Produced/Consumed tag configurations typically require only an IP address update — no ladder logic restructuring. Similarly, if a Siemens S7-300 or S7-1200 was used as the host controller with a custom function block for vision result parsing, the same string-based result format is preserved.

HMI screens built on Rockwell PanelView, Siemens SIMATIC HMI TP700, or Weintek cMT series panels that display pass/fail results, inspection counts, or live image feeds via the Cognex display protocol will continue to function after the swap, provided the replacement unit is assigned the same IP address as the legacy device. No HMI screen redesign is required in most standard retrofit scenarios.

If the original installation included a Cognex In-Sight 2000 Series lens and illumination kit — such as a C-mount lens with integrated LED ring light — these optics and lighting accessories are mechanically compatible with the ISV2-01P-X’s standard C-mount interface. Focal length and aperture settings from the original job file serve as the starting point for the post-swap calibration run.

Downtime Control During System Migration

Minimizing production downtime during a vision system swap requires a parallel preparation strategy. Before the scheduled maintenance window, the ISV2-01P-X should be pre-configured on a bench setup: assign the target IP address, load the exported job files from the legacy unit, and perform a preliminary calibration pass using a reference calibration target. This bench validation confirms that the replacement unit’s inspection logic produces equivalent pass/fail outputs before it enters the production environment.

During the physical swap, the recommended sequence is: (1) power down the control cabinet and lock out the 24 VDC supply rail; (2) disconnect the CCB-84901 I/O cable and Ethernet patch cable from the legacy In-Sight 2000; (3) remove the legacy unit from its mounting bracket; (4) install the ISV2-01P-X using the existing bracket hardware; (5) reconnect I/O and Ethernet cables; (6) restore power and confirm the unit boots to the pre-loaded job. In most cases, this physical exchange can be completed within a 30–45 minute maintenance window.

Post-installation, the critical verification steps are: confirm Ethernet connectivity from the host PLC or PC, trigger a test inspection cycle using the existing PLC output signal, verify that pass/fail discrete outputs are received correctly at the PLC input card, and review the first 20–50 inspection results against the known-good baseline. If the facility uses a Cognex DataMan barcode reader or secondary vision station in the same line, those devices are unaffected by the ISV2-01P-X swap and continue operating independently.

All units supplied by SMARTNEXMSK undergo pre-shipment functional testing, including power-on verification, I/O continuity check, and Ethernet communication confirmation. Each ISV2-01P-X ships with a 12-month warranty covering hardware defects, ensuring that your retrofit investment is protected from day one of installation.

Retrofit Support FAQ

Q1: Is the ISV2-01P-X a direct drop-in replacement for the Cognex In-Sight 2000 Series?
A: Yes, for the majority of In-Sight 2000 installations. The ISV2-01P-X shares the same 24 VDC power requirement, Ethernet communication protocol, and discrete I/O pinout as the original In-Sight 2000 units. Existing job files exported from In-Sight Explorer can be imported with a compatibility revision check. Minor recalibration is required after physical installation, but no PLC or HMI reprogramming is typically needed.

Q2: What wiring changes are required during the retrofit?
A: In most cases, none. The ISV2-01P-X uses the same CCB-84901 series I/O cable connector and the same terminal block pin assignments as the legacy In-Sight 2000. Engineers should verify the wiring diagram against the ISV2-01P-X installation guide before proceeding, but field experience consistently shows that existing cabinet wiring can be reused without modification.

Q3: How do I verify compatibility before committing to the replacement?
A: Provide your legacy unit’s full part number (e.g., 825-10567-1R or 821-10005-1R), your PLC model, and your communication protocol to our technical team at sales@smartnexmsk.com. We will confirm compatibility, advise on any firmware version considerations, and provide a pre-shipment test report for your records.

Q4: What does the 12-month warranty cover?
A: The 12-month warranty covers all hardware defects in materials and workmanship from the date of shipment. It includes free replacement or repair of the ISV2-01P-X unit if a hardware fault is confirmed. The warranty does not cover damage resulting from incorrect installation, overvoltage, or physical impact. Our team provides remote commissioning support at no additional charge during the warranty period.


© 2026 SMARTNEXMSK. All rights reserved.
Original Source: https://smartnexmsk.com
Contact: sales@smartnexmsk.com | +86 18259474341

Request Quote WhatsApp Email