Automation Part SmartNexMSK Catalog

CTI E17322780 Maintenance-Ready Spare CRYOLINE

CTI E17322780 original CRYOLINE cryogenic hose assembly spare. SKU E17322780/8043532G004. Industrial replacement, 12-month warranty, tested before shipment.

SKUE17322780 8043532G004 V710C 0090-70002
BrandCTI — Cryogenic Technology Inc.
SeriesOther series
CTI — Cryogenic Technology Inc. E17322780 8043532G004 V710C 0090-70002 Cryogenic Hose Assembly
Model context is attached to every quote action. Use WhatsApp for urgent downtime, or Email for purchasing records.
Model checkSKU and compatibility review Quality evidencePhotos and label notes when available Export supportPacking, courier, and delivery notes
Product Information

Model Details

SKU / Model E17322780 8043532G004 V710C 0090-70002
Brand CTI — Cryogenic Technology Inc.
Product Type Cryogenic Hose Assembly
Series Other series
Catalog Category Business & Industrial > Automation, Control & Flow Devices
Country of Origin US
Tags cryogenic-hose, CRYOLINE, CTI, E17322780, industrial-spare
Catalog Paths

Continue from this exact model

Use the live catalog paths below to compare the same brand, product type, or series before sending your RFQ.

RFQ Intent Desk

Choose the right sourcing path for this model

Each action carries the product model and intent into the inquiry record so the sales follow-up starts with useful context.

Exact Model Quote

Use this path when the SKU, brand, quantity, and destination are already confirmed.

Start
Replacement Check

Use this path for old, obsolete, or uncertain models that need compatibility review.

Start
Quality Confirmation

Ask for label photos, packing notes, documentation, or pre-shipment checks.

Start
Urgent Dispatch

Route downtime or maintenance requests with target dispatch timing and courier country.

Start
Description

CTI E17322780 Maintenance-Ready Spare CRYOLINE Overview

CTI E17322780 Maintenance-Ready Spare CRYOLINE: Spare Replacement & Industrial Downtime Risk Control

The CTI E17322780 (cross-reference: 8043532G004, V710C, 0090-70002) is an original CRYOLINE series pressurized fixture hose assembly manufactured by Cryogenic Technology Inc. (CTI). Designed for cryogenic vacuum systems and semiconductor process equipment, this hose assembly is a critical fluid-transfer component within CTI cryopump platforms. When this part degrades or fails, it directly impacts cryopump regeneration cycles, vacuum integrity, and overall process uptime — making rapid spare replacement essential for any maintenance-driven operation.

For maintenance engineers managing CTI cryopump systems, the E17322780 hose assembly is a scheduled-replacement item that should be stocked as part of a proactive spare parts program. Its role in pressurized helium or nitrogen transfer lines means that any leak, kink, or fitting failure can trigger unplanned downtime across the entire vacuum system. Procurement engineers sourcing this part should verify compatibility with the installed CRYOLINE series configuration and confirm fitting standards before ordering.

SMARTNEXMSK supplies the CTI E17322780 as a tested, original-specification spare with a 12-month warranty, supporting fast dispatch for emergency replacement and long-term supply agreements for planned maintenance programs.

Spare Maintenance Table

Parameter Specification / Detail
Part Number E17322780
Cross-Reference SKU 8043532G004 / V710C / 0090-70002
Brand CTI — Cryogenic Technology Inc.
Series CRYOLINE
Product Type Cryogenic Hose Assembly (Pressurized Fixture)
Application Cryopump helium/nitrogen transfer lines; vacuum system fluid circuits
Compatibility CTI CRYOLINE series cryopumps; compatible with CTI-8, CTI-10, On-Board series platforms (verify with system documentation)
Operating Environment Cryogenic temperatures; clean-room and semiconductor fab environments
Installation Direct OEM replacement; verify fitting orientation and torque spec per CTI service manual
Maintenance Interval Inspect at each scheduled regeneration cycle; replace at first sign of wear, cracking, or fitting looseness
Origin United States
Warranty 12 Months — tested before shipment
Supply Lead Time In-stock; same-day or next-business-day dispatch available

Maintenance Planning for Continuous Operation

When replacing the CTI E17322780 hose assembly during a scheduled or emergency maintenance event, a thorough inspection of the surrounding system is strongly recommended to prevent repeat failures and maximize uptime between service intervals.

Maintenance engineers should begin by inspecting the CTI compressor unit (commonly the 8200 or 9600 series) for oil contamination or pressure irregularities that may have contributed to hose stress. The adsorber assembly (e.g., CTI 8032115G001) should be checked for saturation, as a degraded adsorber accelerates wear on connected hose assemblies. The helium supply line fittings and Swagelok-type compression fittings at both ends of the hose run should be re-torqued or replaced if any micro-leakage is detected.

On the electrical and control side, the CTI cryopump temperature controller (such as the 8110 or 8200 controller module) should be verified for accurate cold-head temperature readings, as abnormal thermal cycling can shorten hose service life. The roughing pump isolation valve and its solenoid actuator should be tested for proper sequencing during regeneration. If the system uses a CTI On-Board compressor interface cable or remote diagnostics module, confirm that communication signals are clean and that no fault codes are latched.

For control cabinet inspections in facilities running multiple cryopump stations, also verify the power distribution terminal blocks feeding the compressor, the 24VDC control power supply for valve solenoids, and any pressure transducers or vacuum gauges (e.g., Pirani or Penning type) monitoring the foreline. A failed pressure transducer can mask a developing hose leak until catastrophic failure occurs. Additionally, inspect flexible conduit and cable management around the hose routing path to ensure no abrasion points exist that could accelerate external hose wear.

For facilities managing aging CTI cryopump fleets, stocking the E17322780 alongside the CTI cold head rebuild kit, adsorber assembly, and compressor service kit as a coordinated spare set is a best-practice approach to reducing mean time to repair (MTTR) and extending system service life beyond OEM end-of-support timelines.

Site Replacement Workflow

Step 1 — Isolation & Lockout: Follow site LOTO procedures. Vent the cryopump to atmosphere and allow the cold head to warm to ambient temperature before disconnecting any hose fittings. Never disconnect pressurized cryogenic lines.

Step 2 — Fitting Inspection: Before installing the E17322780, inspect both mating fittings on the compressor and cryopump body for thread damage, corrosion, or O-ring degradation. Replace O-rings and backup rings as required using CTI-specified materials.

Step 3 — Hose Routing: Route the new hose assembly following the original path, maintaining minimum bend radius per CTI installation guidelines. Avoid sharp bends or contact with hot surfaces. Secure with original clamps or equivalent stainless-steel clamps.

Step 4 — Leak Check: After connection, perform a helium leak check or pressure hold test per site protocol before returning the system to operation. Document results in the maintenance log.

Step 5 — System Restart & Verification: Restart the compressor and monitor cold-head temperature pull-down. Confirm vacuum base pressure is achieved within the expected timeframe. Log the replacement date and part serial number for traceability.

This workflow supports direct replacement of legacy hose assemblies in older CTI CRYOLINE installations, reducing downtime to a single shift in most cases and maintaining full system compatibility without hardware modification.

Spare Parts Support FAQ

Q1: Is the CTI E17322780 compatible with all CRYOLINE series cryopumps?
The E17322780 is designed for CTI CRYOLINE series pressurized fixture applications. Compatibility should be verified against your specific cryopump model and compressor configuration using the CTI service manual or by cross-referencing the alternate SKUs (8043532G004, V710C, 0090-70002). Contact SMARTNEXMSK with your system model number for confirmation before ordering.

Q2: What does the 12-month warranty cover, and how is the part tested before shipment?
All CTI E17322780 units supplied by SMARTNEXMSK are inspected for dimensional integrity, fitting condition, and hose body integrity prior to dispatch. The 12-month warranty covers manufacturing defects and premature failure under normal operating conditions. Warranty claims are supported with replacement dispatch and technical documentation.

Q3: How should we manage inventory for this part in a multi-pump facility?
For facilities operating three or more CTI cryopumps, we recommend maintaining a minimum of one E17322780 hose assembly per four pumps as a rolling spare. Pair this with adsorber assemblies and compressor service kits to enable full regeneration-cycle maintenance without waiting on parts procurement. SMARTNEXMSK supports blanket purchase orders and scheduled delivery programs for high-volume facilities.

Q4: Can this part be used to extend the life of an end-of-support CTI cryopump system?
Yes. The E17322780 is a direct OEM-specification replacement that restores original fluid-transfer performance in aging CRYOLINE systems. Many facilities use proactive hose replacement as part of a broader system-life-extension strategy, deferring capital equipment replacement by maintaining critical wear components. SMARTNEXMSK maintains long-term supply capability for this and related CTI spare parts.


© 2026 SMARTNEXMSK. All rights reserved.
Original Source: https://smartnexmsk.com
Contact: sales@smartnexmsk.com | +86 18259474341

Request Quote WhatsApp Email