Product Information

Model Details

SKU / Model BK300D01
Brand DELIXI
Product Type Control Transformer
Series BK Series
Catalog Category Business & Industrial > Electrical Equipment > Power Supplies
Tags BK Series, BK300D01, Control Transformer, DELIXI, Industrial Spare
Catalog Paths

Continue from this exact model

Use the live catalog paths below to compare the same brand, product type, or series before sending your RFQ.

RFQ Intent Desk

Choose the right sourcing path for this model

Each action carries the product model and intent into the inquiry record so the sales follow-up starts with useful context.

Exact Model Quote

Use this path when the SKU, brand, quantity, and destination are already confirmed.

Start
Replacement Check

Use this path for old, obsolete, or uncertain models that need compatibility review.

Start
Quality Confirmation

Ask for label photos, packing notes, documentation, or pre-shipment checks.

Start
Urgent Dispatch

Route downtime or maintenance requests with target dispatch timing and courier country.

Start
Description

DELIXI BK300D01 Spare for BK Series Automation Overview

DELIXI BK300D01 Maintenance-Ready Spare for BK Series Automation

The DELIXI BK300D01 is a 300VA single-phase dry-type control transformer engineered for continuous-duty industrial environments. As a maintenance-ready spare, it is designed to support rapid in-situ replacement within BK Series control panels, minimising unplanned downtime and restoring system availability with minimal intervention. For maintenance engineers managing aging automation infrastructure, holding a verified BK300D01 spare on the shelf is a proven strategy for reducing mean time to repair (MTTR) and protecting production continuity.

This unit delivers stable secondary control voltage to PLC I/O power rails, relay coil circuits, HMI power supplies, and field instrument loops. Its compact footprint and standardised mounting dimensions make it directly interchangeable with legacy BK Series installations without panel modification. Each unit is factory-tested prior to dispatch and ships with a 12-month warranty covering manufacturing defects and electrical performance.

For procurement engineers, the BK300D01 represents a low-risk, high-availability spare that integrates into existing spare parts programmes without requiring engineering change orders. Long-term supply continuity is supported through established distributor channels, ensuring replenishment lead times remain predictable for annual maintenance budgets.

Spare Maintenance Table

Parameter Specification
SKU / Model BK300D01
Brand DELIXI
Series BK Series
Type Single-Phase Dry-Type Control Transformer
Rated Capacity 300 VA
Primary Voltage 380V / 220V AC (configurable)
Secondary Voltage 36V / 24V / 6V (application-dependent)
Frequency 50 Hz
Insulation Class B / F (per unit marking)
Mounting Panel / DIN rail compatible
Application Environment Indoor, non-condensing, industrial control cabinets
Origin China (CN)
Compatibility BK Series control panels; DELIXI automation systems
Maintenance Recommendation Inspect winding insulation resistance annually; verify output voltage under load at each planned shutdown
Warranty 12 Months — covers manufacturing defects and electrical performance

Maintenance Planning for Continuous Operation

When scheduling a planned replacement of the BK300D01, maintenance engineers should treat the intervention as an opportunity for a broader control cabinet inspection. The transformer feeds downstream components whose condition directly affects system reliability after the spare is installed.

Begin by verifying the integrity of the primary fuse or miniature circuit breaker (MCB) protecting the transformer input — a blown fuse or tripped breaker is frequently the first indicator of a failing transformer rather than a load fault. Inspect the terminal blocks (such as DELIXI TD or UK series) on both primary and secondary sides for signs of overheating, discolouration, or loose terminations, as high-resistance connections accelerate transformer ageing.

On the secondary side, check the 24VDC power supply module (e.g., DELIXI or third-party SMPS units) that may be fed from the transformer’s low-voltage winding. Confirm output voltage stability under full I/O load before closing the cabinet. Relay modules and intermediate relay bases in the same circuit should be inspected for contact wear, particularly if the transformer failure was preceded by erratic coil switching behaviour.

For PLC-integrated panels, verify that the CPU module’s power input voltage is within specification after the transformer swap — voltage sag during the transition can corrupt memory modules or trigger watchdog faults. I/O expansion modules and their backplane connectors should be reseated if the panel has experienced vibration or thermal cycling. Communication modules (such as PROFIBUS DP or Modbus RTU adapters) should be checked for link status after power restoration, as some modules require a clean power cycle to re-establish network presence.

Signal isolators and loop-powered transmitters connected to analogue I/O channels are sensitive to supply voltage variation; confirm 4–20 mA loop integrity after the replacement. Where HMI panels (such as DELIXI or Weinview touch screens) share the same transformer secondary, verify display startup and communication with the PLC host before returning the system to automatic mode. Surge protection devices (SPDs) on the primary supply rail should also be visually inspected — a transformer failure caused by a voltage spike may have degraded the SPD, leaving the replacement unit unprotected.

Site Replacement Workflow

Step 1 — Isolation and Lockout: De-energise the panel at the main isolator and apply LOTO (Lockout/Tagout) per site procedure. Confirm absence of voltage on the transformer primary terminals using a calibrated multimeter.

Step 2 — Documentation: Photograph existing wiring before disconnection. Record primary and secondary terminal assignments, wire colours, and ferrule labels to ensure accurate reconnection of the replacement BK300D01.

Step 3 — Removal: Disconnect primary and secondary wiring. Remove mounting fasteners. Extract the failed unit and compare physical dimensions and terminal layout with the replacement to confirm interchangeability.

Step 4 — Installation: Mount the BK300D01 spare. Reconnect wiring per the documented terminal assignments. Torque terminal screws to manufacturer specification to prevent loose connections under vibration.

Step 5 — Pre-energisation Check: Verify insulation resistance between primary and secondary windings using a 500V megohmmeter (minimum 1 MΩ acceptable for a new unit). Confirm no short circuits on the secondary load circuit.

Step 6 — Energisation and Verification: Restore power progressively. Measure secondary output voltage under no-load and then full-load conditions. Confirm PLC, HMI, relay, and I/O module status before releasing the system to production.

This workflow is compatible with direct replacement of legacy BK Series transformers of equivalent VA rating, requiring no panel rewiring or engineering change documentation beyond the maintenance record update.

Spare Parts Support FAQ

Q1: What is the recommended spare parts lifecycle strategy for the BK300D01?
For facilities operating BK Series control panels continuously, we recommend holding a minimum of one BK300D01 spare per five installed units, reviewed annually. Transformers in high-cycle or high-ambient-temperature environments should be inspected every 12 months and replaced proactively at the first sign of insulation degradation or output voltage drift beyond ±5% of rated value.

Q2: How is compatibility with my existing BK Series panel confirmed before shipment?
Compatibility is verified against the SKU, rated VA, primary voltage configuration, and secondary voltage tapping. Each BK300D01 unit is cross-referenced against the BK Series product matrix prior to dispatch. If your panel uses a non-standard secondary voltage, please provide the nameplate data from the installed unit so our technical team can confirm the correct tapping configuration before shipment.

Q3: What pre-shipment testing is performed on each unit?
Every BK300D01 spare undergoes electrical performance testing prior to dispatch, including no-load voltage output verification, insulation resistance measurement, and visual inspection for winding and enclosure integrity. Units that do not meet specification are quarantined and not shipped. A test record is available on request.

Q4: What does the 12-month warranty cover, and how are warranty claims handled?
The 12-month warranty covers manufacturing defects, winding failures, and electrical performance deviations attributable to the unit itself under normal operating conditions. It does not cover damage resulting from incorrect installation, overvoltage events, or operation outside rated parameters. Warranty claims are handled directly through our sales team — contact sales@smartnexmsk.com with the order reference, installation date, and a description of the fault. Replacement units are dispatched upon fault confirmation.

© 2026 SMARTNEXMSK. All rights reserved.