BALZERS LVM215-5BMO-X17 Maintenance-Ready Spare for EVA 100 Automation
The BALZERS LVM215-5BMO-X17 is a pneumatic right-angle vacuum valve from the EVA 100 series, designed for DN100 ISO-K flange connections in high-demand industrial vacuum systems. As a maintenance-ready spare, this unit is sourced, inspected, and dispatched to support rapid replacement in coating systems, thin-film deposition lines, semiconductor process chambers, and industrial vacuum furnaces where unplanned downtime carries significant operational cost.
For maintenance engineers managing aging BALZERS vacuum systems, securing a verified OEM-equivalent LVM215-5BMO-X17 spare is a critical step in any planned shutdown or emergency recovery workflow. This valve controls gas flow isolation between vacuum chambers and roughing pump lines, making its reliable operation essential to process integrity. A failed or leaking valve at this position can cascade into extended pump-down times, contaminated process environments, and costly production losses.
This spare is tested prior to shipment, packaged to prevent flange surface damage, and backed by a 12-month warranty covering manufacturing defects and functional performance. Long-term supply continuity is supported for customers managing legacy EVA 100 system fleets.
Spare Maintenance Table
| SKU / Part Number | LVM215-5BMO-X17 DN100 ISO-K EVA 100 PA 0021-09718 |
| Brand | BALZERS (Pfeiffer Vacuum Group) |
| Series | EVA 100 |
| Valve Type | Pneumatic Right-Angle Vacuum Valve |
| Flange Connection | DN100 ISO-K |
| Actuation | Pneumatic (5/2-way solenoid, 24 VDC / 110–230 VAC options) |
| Sealing | Viton O-ring, metal body |
| Operating Pressure Range | Atmosphere to 10⁻⁸ mbar (high vacuum compatible) |
| Leak Rate | < 1 × 10⁻⁹ mbar·l/s (He) |
| Actuator Supply Pressure | 4–8 bar (compressed air or N₂) |
| Body Material | Aluminum alloy, anodized |
| Weight | Approx. 2.6 kg |
| Country of Origin | Germany |
| Compatibility | BALZERS EVA 100 series vacuum systems; ISO-K DN100 standard flanges |
| Installation | Inline, any orientation; torque flanges per ISO-K specification |
| Application Environment | Coating systems, semiconductor process chambers, vacuum furnaces, R&D vacuum lines |
| Maintenance Recommendation | Inspect O-ring and seat annually or every 50,000 cycles; replace actuator solenoid coil if response time degrades |
| Warranty | 12 Months — covers manufacturing defects and functional performance |
| Condition | New / Surplus New / Tested Refurbished (specify at order) |
| Lead Time | In-stock units ship within 3–5 business days; tested and documented |
Maintenance Planning for Continuous Operation
When scheduling a planned replacement of the LVM215-5BMO-X17 in an EVA 100 vacuum system, experienced maintenance engineers treat this valve as one node in a broader inspection and replacement cycle. A thorough site review should extend to the complete pneumatic and vacuum circuit surrounding this valve.
Begin with the solenoid valve pilot unit (typically a 5/2-way 24 VDC solenoid, often a FESTO or SMC equivalent mounted on the actuator body) — if the LVM215-5BMO-X17 has been slow to actuate or failed to open fully, the solenoid coil or its pilot air supply line is frequently the root cause. Inspect the compressed air filter-regulator unit upstream of the actuator supply; moisture or particulate contamination in the pilot air is a common cause of premature actuator seal wear.
On the vacuum side, check the DN100 ISO-K centering ring and O-ring set at both flanges — these are consumable items that should be replaced whenever the valve is removed. If the system uses a BALZERS TPH/TMH turbomolecular pump downstream of this valve, verify that the pump’s inlet screen is clean and that the pump’s own isolation valve (such as a BALZERS EVN 116 or EVN 010 series valve) is sealing correctly.
For the roughing side, inspect the backing line valve and the roughing pump inlet filter. A worn BALZERS DUO rotary vane pump or its oil mist filter can introduce backstreaming contamination that accelerates O-ring degradation in the LVM215-5BMO-X17 and adjacent valves. If the system includes a BALZERS RVC 300 or RVC 400 vacuum gauge controller, verify that the Pirani and Penning gauge heads are reading correctly — inaccurate pressure readings can mask slow valve leaks for extended periods.
In control cabinet inspections, check the 24 VDC power supply rail feeding the solenoid coil and any associated PLC digital output module (I/O card) that drives the valve command signal. A marginal power supply voltage or a failing DO channel can produce intermittent valve behavior that is difficult to diagnose without a scope. Also verify the position feedback sensor (reed switch or proximity sensor) mounted on the actuator — a faulty feedback signal can cause the control system to report a valve fault even when the valve is mechanically functional. Finally, inspect the terminal block wiring in the control cabinet for the solenoid circuit; loose or corroded terminals are a frequent source of intermittent faults in high-vibration industrial environments.
Site Replacement Workflow
Step 1 — Isolation and venting: Confirm system is at atmospheric pressure. Close all adjacent isolation valves. Disconnect the pilot air supply line and de-energize the solenoid coil at the terminal block before removing any flange clamps.
Step 2 — Flange removal: Remove ISO-K DN100 clamps and centering rings. Inspect the mating flange faces on the chamber and pump line for scoring or contamination. Clean with IPA and lint-free wipes before installing the replacement valve.
Step 3 — New valve installation: Install new DN100 ISO-K centering ring and O-ring. Position the LVM215-5BMO-X17 and torque clamps evenly to specification. Reconnect pilot air supply and solenoid wiring. Verify actuator supply pressure is within 4–8 bar.
Step 4 — Functional test: Energize solenoid and confirm valve opens and closes fully. Verify position feedback signal at the PLC I/O module. Perform a rough leak check with a portable vacuum gauge before committing to a full pump-down cycle.
Step 5 — System recommission: Resume normal pump-down sequence. Monitor base pressure achievement time against historical baseline. Log the replacement in the maintenance management system with the new part serial number and installation date.
This workflow minimizes system downtime to typically under 2 hours for a prepared maintenance team with the spare on-site, compared to days or weeks waiting for an unplanned procurement cycle.
Spare Parts Support FAQ
Q1: Is the LVM215-5BMO-X17 a direct drop-in replacement for older BALZERS EVA 100 series valves?
Yes. The LVM215-5BMO-X17 is designed to the EVA 100 series dimensional and flange standard (DN100 ISO-K). It is a direct mechanical replacement for earlier EVA 100 pneumatic right-angle valves of the same flange size. Verify the actuator solenoid voltage matches your control system (24 VDC or 110/230 VAC) before installation.
Q2: What pre-shipment testing is performed on this spare?
Each unit undergoes functional actuation testing (open/close cycle verification), leak rate check to confirm < 1 × 10⁻⁹ mbar·l/s (He), and visual inspection of flange sealing surfaces and O-ring condition. A test report is available upon request for quality-critical applications.
Q3: What is the recommended spare parts stocking strategy for EVA 100 systems?
For facilities operating multiple EVA 100 systems, we recommend maintaining at minimum one LVM215-5BMO-X17 per system in on-site inventory, along with a set of DN100 ISO-K centering rings and O-rings, a spare solenoid coil for the actuator pilot valve, and a replacement Pirani gauge head for the roughing line. This kit approach supports same-shift recovery from the most common failure modes without waiting for procurement.
Q4: What does the 12-month warranty cover, and how is a warranty claim handled?
The 12-month warranty covers manufacturing defects, seal integrity, and functional performance under normal operating conditions. If a unit fails within the warranty period, contact [email protected] with the order reference and a description of the failure mode. Replacement or repair is arranged with priority handling. Warranty does not cover damage from incorrect installation, operation outside specified pressure or actuator supply ranges, or contamination from the process environment.
© 2026 SMARTNEXMSK. All rights reserved.