GE IC695ACC302 Retrofit-Ready Battery Module for PACSystems RX3i Control Systems
The GE IC695ACC302 is an Auxiliary Smart Battery Module engineered for seamless integration into GE PACSystems RX3i control architectures. As legacy GE Series 90-30 and early RX3i installations reach end-of-service milestones, the IC695ACC302 has become a critical component in modernization projects — providing a direct, drop-in upgrade path that preserves existing rack infrastructure, program logic, and field wiring while extending system service life by years. Whether you are replacing a failed unit on an active production line or executing a planned control cabinet upgrade, this module delivers the power backup reliability that mission-critical automation demands.
SMARTNEXMSK maintains verified in-stock inventory of the IC695ACC302, with pre-shipment functional testing, original or equivalent packaging, and a 12-month warranty covering defects in materials and workmanship. Units are dispatched within 24–48 hours of order confirmation, supporting urgent maintenance windows and planned shutdown schedules alike.
Upgrade Compatibility Table
| Parameter | IC695ACC302 Specification | Retrofit Notes |
|---|---|---|
| Compatible Racks | IC695CHS012, IC695CHS016, IC695CHS007 | Direct slot insertion; no adapter required |
| Backplane Interface | RX3i universal backplane bus | Compatible with all RX3i CPU and expansion racks |
| Battery Chemistry | Lithium, smart-managed | Replaces earlier non-smart battery modules |
| Communication | Backplane diagnostic reporting to CPU | Status visible in Proficy Machine Edition (PME) |
| Power Draw | Minimal standby; self-regulating charge circuit | No additional power supply capacity required |
| Installation | Hot-swap capable (verify with CPU firmware rev) | Confirm IC695CPU310/315/320 firmware ≥ v7.80 |
| Replacement For | IC693ACC301, IC693ACC302 (Series 90-30 era) | Requires rack adapter for 90-30 chassis |
| Debugging Tool | Proficy Machine Edition Logic Developer | Monitor battery status via hardware configuration |
| Warranty | 12 Months | Covers defects; excludes physical damage |
Retrofit Planning for Existing Automation Systems
Successful integration of the IC695ACC302 into an existing PACSystems RX3i installation begins well before the module arrives on site. Engineers should start by auditing the current rack configuration — identifying the IC695CHS012 or IC695CHS016 chassis slot assignments, confirming available slot positions, and reviewing the IC695PSA040 or IC695PSD040 power supply load budget to ensure the auxiliary battery circuit does not push the supply beyond its rated output. In most standard RX3i cabinets, the battery module’s power draw is negligible, but this step is non-negotiable in high-density I/O configurations where the rack is already near capacity.
Terminal wiring is not required for the IC695ACC302 itself — it communicates entirely through the backplane — but adjacent modules such as the IC695MDL654 discrete output module or IC695ALG600 analog input module should be inspected for secure seating before and after the battery module swap. Loose backplane connections are a common source of post-maintenance faults that are incorrectly attributed to the new module.
For systems running the IC695CPU315 or IC695CPU320 as the primary controller, the battery status register is accessible through Proficy Machine Edition’s hardware configuration view. Before replacing the IC695ACC302, export the current hardware configuration file (.hwd) and store it offline. This protects against accidental configuration loss during the swap and provides a reference baseline for post-installation verification. If the system also includes an IC695ETM001 Ethernet module or IC695PBM300 PROFIBUS Master module, confirm that these communication links remain active throughout the maintenance window — unexpected communication drops can trigger upstream SCADA alarms that complicate the retrofit timeline.
In multi-rack systems using IC695CHS016 expansion chassis connected via IC695LRE001 LAN Redundancy or fiber expansion cables, the battery module replacement should be sequenced to avoid simultaneous disruption of the primary and expansion racks. Plan the swap during a scheduled maintenance window and coordinate with the HMI operator to suppress non-critical alarms. If the facility uses a GE CIMPLICITY or iFIX SCADA platform, pre-configure an alarm suppression window in the historian to prevent false downtime entries in the production record.
Downtime Control During System Migration
Minimizing unplanned downtime during an IC695ACC302 replacement requires a structured pre-swap checklist. First, verify that the IC695CPU310 or equivalent CPU is in RUN mode and that all I/O modules — including any IC695MDL740 discrete input modules and IC695ALG728 analog output modules — are reporting healthy status in the hardware configuration. A pre-existing I/O fault will complicate post-swap diagnostics and may be incorrectly attributed to the battery module replacement.
Second, confirm that the existing battery module’s charge state is logged. If the outgoing module has already failed, the CPU’s retentive memory may have been at risk; verify that the program logic stored in the IC695CPU315’s flash memory is intact by performing a forced store-to-flash operation via Proficy Machine Edition before removing the old module. This ensures that even in a worst-case power interruption during the swap, the control program survives.
Third, for hot-swap installations, have the replacement IC695ACC302 pre-staged in the cabinet before initiating removal of the old unit. The swap window — from module extraction to full seating and backplane recognition — should not exceed 60 seconds in a live system. Post-installation, monitor the CPU’s battery status diagnostic for 10–15 minutes to confirm the new module is charging correctly and reporting to the controller. Document the swap time, technician name, and post-installation status in the site maintenance log to satisfy ISO 9001 or IEC 62443 audit requirements.
For facilities where even brief control interruptions are unacceptable, consider staging a temporary IC695CPU315 hot-standby configuration using the IC695HPS010 Hot Standby CPU module if the system architecture supports it. This allows the primary CPU to transfer control to the standby unit during the battery module swap, achieving zero-impact maintenance on the live process.
Retrofit Support FAQ
Q1: Is the IC695ACC302 a direct drop-in replacement for the IC693ACC302 used in GE Series 90-30 systems?
A: Not directly. The IC695ACC302 is designed for the PACSystems RX3i backplane and is not physically or electrically compatible with the Series 90-30 IC693 chassis without a rack adapter. If you are migrating from a Series 90-30 platform, the recommended path is to upgrade the chassis to an IC695CHS012 or IC695CHS016 RX3i rack, at which point the IC695ACC302 installs natively. Contact our technical team to confirm the full BOM for your specific migration.
Q2: Can I install the IC695ACC302 while the system is running (hot-swap)?
A: Hot-swap capability depends on the CPU firmware revision. IC695CPU310, IC695CPU315, and IC695CPU320 controllers running firmware v7.80 or later support hot-swap of the auxiliary battery module. Always verify the firmware version in Proficy Machine Edition before attempting a live swap. If the firmware is below the required revision, a controlled shutdown is required.
Q3: What pre-shipment testing does SMARTNEXMSK perform on the IC695ACC302?
A: Every IC695ACC302 unit undergoes functional verification prior to dispatch, including backplane communication check, battery charge circuit validation, and visual inspection for connector integrity. Units are shipped with a test report and are covered by a 12-month warranty from the date of delivery. Expedited testing documentation is available on request for customers with IEC 62443 or ISO 9001 compliance requirements.
Q4: What information do I need to provide to confirm compatibility before ordering?
A: Please provide your current CPU model (e.g., IC695CPU315), rack model (e.g., IC695CHS012), firmware version, and the model number of the battery module being replaced. This allows our engineering team to confirm compatibility, identify any firmware prerequisites, and advise on any wiring or configuration changes required before installation.