Honeywell C7015A1076 Retrofit UV Flame Detector C7015

Honeywell C7015A1076 retrofit UV flame detector for C7015 Burner Safeguard Series. Drop-in replacement, wiring-compatible, 12-month warranty, fast shipping.

SKU / Model C7015A1076
Brand Honeywell
Product Type UV Flame Detector
Country of Origin US
Catalog Category Business & Industrial > Automation, Control & Flow Devices > Sensors
Model checkSKU and compatibility Quality evidencePhotos on request Export supportPacking and delivery
Description

Honeywell C7015A1076 Retrofit UV Flame Detector C7015 Overview

Honeywell C7015A1076 Retrofit-Ready UV Flame Detector for C7015 Series Control Systems

The Honeywell C7015A1076 is a UV flame detector engineered for direct retrofit and drop-in replacement within the C7015 Burner Safeguard Series. As legacy combustion control systems age out of manufacturer support, plant engineers and maintenance teams increasingly rely on verified replacement units to sustain burner management continuity without triggering full-system overhauls. The C7015A1076 addresses this need precisely — delivering OEM-equivalent UV sensing performance in a form factor that preserves existing wiring, conduit routing, and mounting geometry.

Whether you are restoring a failed detector on a process heater, upgrading a boiler burner management system, or consolidating spare-parts inventory ahead of a planned shutdown, the C7015A1076 provides a reliable, tested, and immediately deployable solution. Each unit ships with a 12-month warranty covering manufacturing defects and functional performance under normal operating conditions.

Upgrade Compatibility Table

Parameter C7015A1076 (Replacement) Notes / Retrofit Guidance
Detector Type UV (Ultraviolet) Flame Sensor Direct replacement for C7015 series UV detectors
Mounting Interface Standard C7015 flange / sight-pipe mount No mechanical modification required
Wiring Compatibility Matches OEM terminal layout Verify terminal polarity before energizing
Supply Voltage 120 VAC / 240 VAC (model-dependent) Confirm local supply voltage before installation
Communication / Signal Analog flame signal output Compatible with R4140, R7140, and RM7800 series relay modules
Burner Control Compatibility C7015 Burner Safeguard Series Also compatible with RM7800L, RM7840L burner controllers
Installation Requirement Sight-pipe alignment critical Clean sight pipe; verify UV window integrity before commissioning
Commissioning Check Flame signal strength verification Use Honeywell W7076A or equivalent signal analyzer
Warranty 12 Months Covers manufacturing defects under normal operating conditions

Retrofit Planning for Existing Automation Systems

Replacing a UV flame detector in an operating facility requires careful coordination across multiple system layers. The C7015A1076 is most commonly deployed in retrofit scenarios involving Honeywell Burner Safeguard relay modules such as the RM7800L, RM7840L, or the older R4140M series. In these configurations, the flame detector interfaces directly with the burner control relay, which monitors UV signal strength to confirm stable flame presence during the ignition and run cycles.

Before removing the existing detector, technicians should document the current flame signal reading using a Honeywell W7076A Flame Signal Analyzer or equivalent diagnostic tool. This baseline reading is essential for post-installation comparison and commissioning sign-off. The sight pipe should be inspected for carbon deposits, moisture ingress, or UV window fouling — all of which can suppress signal strength and cause nuisance lockouts even with a new detector installed.

Terminal wiring on the C7015A1076 follows the standard C7015 series layout. Technicians should cross-reference the existing wiring diagram against the replacement unit’s terminal designations before re-energizing the circuit. In systems where the burner controller is a Honeywell S7800A Keyboard Display Module or an integrated RM7800 series unit, the flame amplifier card — such as the R7847A or R7849A — must be confirmed compatible with the UV detector type. Swapping from an infrared (IR) detector to a UV detector, or vice versa, requires a corresponding amplifier card change.

For facilities running multiple burners on a common control panel, the C7015A1076 retrofit should be staged burner-by-burner to maintain combustion continuity on adjacent units. The control panel’s power supply module should be verified for adequate current capacity to support the replacement detector, particularly in older cabinets where the original power supply may be operating near its rated output. In some installations, the 7800 SERIES Relay Module’s address configuration or DIP switch settings may need to be reviewed if the replacement detector is installed on a different physical position within the burner management rack.

Facilities that have migrated their HMI from legacy Honeywell PanelView-equivalent displays to modern SCADA platforms should verify that the flame status signal — typically a discrete digital output from the burner relay — is correctly mapped in the new HMI configuration. The C7015A1076 does not alter the relay output logic, so existing HMI alarm and status tags should remain valid after replacement. However, if the site has recently upgraded from an older RM7800 to a newer RM7840 or RM7890 series controller, the flame amplifier slot and detector wiring should be re-verified against the updated controller’s wiring diagram.

For sites managing spare-parts inventory across multiple boiler or heater units, stocking the C7015A1076 alongside compatible components such as the Q179A ignition transformer, S89E primary control, or the 7800 SERIES Purge Timer Card provides a comprehensive retrofit kit that covers the most common failure points in aging burner management systems. This approach minimizes emergency procurement lead times and supports planned maintenance schedules.

Downtime Control During System Migration

Minimizing combustion system downtime during a UV flame detector replacement requires a structured pre-outage preparation protocol. Before scheduling the replacement window, the maintenance team should have the C7015A1076 on-site, pre-inspected, and confirmed against the existing unit’s part number and wiring diagram. A cold-swap procedure — performed during a planned burner shutdown rather than an emergency response — eliminates the time pressure that leads to wiring errors and commissioning delays.

The replacement sequence should begin with a controlled burner shutdown, followed by isolation of the burner control circuit at the panel. The existing C7015 detector should be removed with the sight pipe cap installed immediately to prevent contamination of the UV window port. The C7015A1076 should be installed, wired, and torqued to specification before the sight pipe cap is removed and the UV window is exposed to the combustion environment.

After installation, the burner management system should be powered up in a test mode — if supported by the RM7800 or RM7840 series controller — to verify flame signal strength before initiating a live ignition sequence. The flame signal reading should meet or exceed the minimum threshold specified in the burner management system’s commissioning record. If the signal is below threshold, the sight pipe alignment, UV window cleanliness, and amplifier card compatibility should be re-checked before proceeding.

For facilities with redundant burner trains, the replacement can be performed on one train while the parallel train maintains process heat load, effectively reducing the operational impact of the maintenance window to zero. This approach is particularly effective in process heating applications where continuous heat supply is critical to production continuity. Proper documentation of the replacement — including the new unit’s serial number, installation date, flame signal reading, and technician sign-off — should be recorded in the facility’s maintenance management system to support future warranty claims and regulatory compliance audits.

Retrofit Support FAQ

Q: Is the C7015A1076 a direct drop-in replacement for all C7015 series UV flame detectors?
A: The C7015A1076 is designed as a direct mechanical and electrical replacement for C7015 series UV detectors sharing the same mounting flange and terminal layout. Always verify the existing unit’s wiring diagram and confirm the flame amplifier card type (UV vs. IR) before installation. If the existing system uses an R7847A or R7849A amplifier card configured for UV detection, the C7015A1076 is compatible without amplifier changes.

Q: What commissioning steps are required after installing the C7015A1076?
A: After installation, verify sight pipe alignment and UV window cleanliness, then power up the burner management system and measure the flame signal strength using a Honeywell W7076A or equivalent analyzer. The signal should meet the minimum threshold in the system’s commissioning record. Perform a full ignition trial, confirm stable flame detection during the run cycle, and document the flame signal reading and installation details in the maintenance log.

Q: Can the C7015A1076 be used with RM7800 and RM7840 series burner controllers?
A: Yes. The C7015A1076 is compatible with RM7800L, RM7800G, RM7840L, and related 7800 SERIES Relay Modules when paired with the appropriate UV flame amplifier card. Confirm the amplifier card model installed in the relay module before replacement. No controller reprogramming is required for a like-for-like detector swap.

Q: What does the 12-month warranty cover, and how is a warranty claim initiated?
A: The 12-month warranty covers manufacturing defects and functional failures under normal operating conditions, including UV tube failure, signal output faults, and housing integrity issues. Warranty claims are initiated by contacting [email protected] with the unit’s serial number, purchase date, and a description of the fault. Units must not have been subjected to physical damage, incorrect wiring, or operation outside the specified voltage and temperature range.

© 2026 SMARTNEXMSK. All rights reserved.
Original Source: https://smartnexmsk.com
Contact: [email protected] | +86 18259474341

Catalog Paths

Continue from this exact model

Use the live catalog paths below to compare the same brand, product type, or series before sending your RFQ.

RFQ Intent Desk

Choose the right sourcing path for this model

Each action carries the product model and intent into the inquiry record so the sales follow-up starts with useful context.

Exact Model Quote

Use this path when the SKU, brand, quantity, and destination are already confirmed.

Start
Replacement Check

Use this path for old, obsolete, or uncertain models that need compatibility review.

Start
Quality Confirmation

Ask for label photos, packing notes, documentation, or pre-shipment checks.

Start
Urgent Dispatch

Route downtime or maintenance requests with target dispatch timing and courier country.

Start
Request Quote WhatsApp Email