Automation Part SmartNexMSK Catalog

LEYBOLD V50-TURBOVAC50-85406-886304-0 Spare TURBOVAC 50

Original LEYBOLD V50-TURBOVAC50-85406-886304-0 spare for TURBOVAC 50 series. Fast replacement, 12-month warranty, tested before shipment. Reduce vacuum.

SKUV50-TURBOVAC50-85406-886304-0
BrandLEYBOLD
SeriesOther series
LEYBOLD V50-TURBOVAC50-85406-886304-0 Turbo Molecular Pump
Model context is attached to every quote action. Use WhatsApp for urgent downtime, or Email for purchasing records.
Model checkSKU and compatibility review Quality evidencePhotos and label notes when available Export supportPacking, courier, and delivery notes
Product Information

Model Details

SKU / Model V50-TURBOVAC50-85406-886304-0
Brand LEYBOLD
Product Type Turbo Molecular Pump
Series Other series
Catalog Category Business & Industrial > Automation, Control & Flow Devices
Tags industrial replacement, LEYBOLD, turbo molecular pump, TURBOVAC 50, vacuum spare part
Catalog Paths

Continue from this exact model

Use the live catalog paths below to compare the same brand, product type, or series before sending your RFQ.

RFQ Intent Desk

Choose the right sourcing path for this model

Each action carries the product model and intent into the inquiry record so the sales follow-up starts with useful context.

Exact Model Quote

Use this path when the SKU, brand, quantity, and destination are already confirmed.

Start
Replacement Check

Use this path for old, obsolete, or uncertain models that need compatibility review.

Start
Quality Confirmation

Ask for label photos, packing notes, documentation, or pre-shipment checks.

Start
Urgent Dispatch

Route downtime or maintenance requests with target dispatch timing and courier country.

Start
Description

LEYBOLD V50-TURBOVAC50-85406-886304-0 Spare TURBOVAC 50 Overview

LEYBOLD V50-TURBOVAC50-85406-886304-0 Spare TURBOVAC 50: Precision Spare for Vacuum System Uptime

Unplanned downtime in vacuum-dependent processes — semiconductor fabrication, thin-film coating, analytical instrumentation, and industrial leak testing — carries significant operational and financial risk. The LEYBOLD V50-TURBOVAC50-85406-886304-0 is an original-specification spare component for the TURBOVAC 50 turbo molecular pump series, engineered to restore system performance rapidly and reliably. Whether you are executing a planned overhaul, responding to a bearing failure alarm, or building a resilient spare parts inventory for a critical vacuum line, this component delivers the dimensional accuracy, material integrity, and compatibility assurance that maintenance engineers and procurement teams require.

The TURBOVAC 50 is a compact, high-performance turbo molecular pump widely deployed in research laboratories, OEM analytical systems, and light industrial vacuum applications. Its rotor-stator assembly, magnetic bearing system, and integrated frequency converter make it a precision instrument — and like all precision instruments, its long-term reliability depends on the availability of correctly specified replacement parts. The V50-TURBOVAC50-85406-886304-0 is sourced to original LEYBOLD specifications, ensuring dimensional fit, dynamic balance tolerances, and material compatibility are maintained across the replacement cycle.

Spare Maintenance Table

Parameter Specification
Part Number / SKU V50-TURBOVAC50-85406-886304-0
Brand LEYBOLD
Compatible Series TURBOVAC 50
Product Type Turbo Molecular Pump Spare Component
Origin Germany (DE)
Application Environment High-vacuum industrial and laboratory systems; semiconductor, coating, and analytical instrumentation
Compatibility LEYBOLD TURBOVAC 50 series turbo molecular pump assemblies
Installation Direct OEM-specification replacement; no field modification required
Pre-Shipment Testing Functional and dimensional inspection performed before dispatch
Warranty 12 Months from date of shipment
Maintenance Recommendation Replace during scheduled pump overhaul or upon bearing/rotor anomaly detection; inspect mating components simultaneously
HS Code 8414.10.00

Maintenance Planning for Continuous Operation

Effective vacuum system maintenance extends well beyond replacing a single component. When servicing a TURBOVAC 50 pump and installing the V50-TURBOVAC50-85406-886304-0, experienced maintenance engineers treat the intervention as an opportunity to audit the entire vacuum circuit and control infrastructure. A structured inspection at this stage prevents secondary failures and maximises the value of the planned downtime window.

Begin with the LEYBOLD TURBOVAC 50 frequency converter / drive electronics — the integrated or external controller that governs rotor acceleration, speed regulation, and bearing current. A worn rotor component often correlates with elevated drive current signatures; if the drive unit shows abnormal thermal history or parameter drift, it should be evaluated for replacement alongside the mechanical spare. Similarly, the pump inlet screen and foreline adapter should be inspected for particulate contamination that may have contributed to rotor wear.

On the backing pump side, verify the condition of the LEYBOLD TRIVAC or SOGEVAC rotary vane backing pump connected to the TURBOVAC 50 foreline. A degraded backing pump that cannot maintain adequate foreline pressure will shorten the service life of any newly installed turbo pump component. Check the backing pump oil level, oil condition, and shaft seal integrity before returning the system to service.

Within the vacuum chamber and interconnecting pipework, inspect all ISO-KF and ISO-K flange seals, centering rings, and O-rings. Elastomeric seals adjacent to a pump that has experienced mechanical distress may have been exposed to elevated temperatures or vibration, compromising their sealing performance. Replace any seals showing compression set, cracking, or surface contamination.

The vacuum gauge and pressure transducer — typically a Pirani or Penning gauge head mounted on the pump inlet or chamber body — should be zero-checked and calibrated after the pump replacement. Gauge drift can mask residual leak paths or outgassing sources that would otherwise be detected during pump-down performance verification. If the system uses a LEYBOLD IONIVAC or THERMOVAC gauge controller, confirm that setpoint thresholds and interlock signals are correctly configured before restarting the process.

For systems with automated process control, review the PLC or DCS interlock logic governing pump start permissives, speed-reached signals, and fault shutdown sequences. A replacement pump component that restores mechanical function will not deliver full system reliability if the control layer has accumulated unacknowledged fault history or misconfigured speed thresholds. Coordinate with the controls team to clear fault logs and verify signal integrity on the pump status I/O channel.

Finally, replenish the spare parts kit consumed during this intervention — including replacement O-rings, inlet screen, and any consumable fasteners — so that the next scheduled maintenance cycle can proceed without procurement delays.

Site Replacement Workflow

The V50-TURBOVAC50-85406-886304-0 is designed for direct replacement of the corresponding OEM component in the TURBOVAC 50 assembly, eliminating the need for field machining, shimming, or custom adaptation. The following workflow is recommended for minimising replacement time and ensuring a clean return to service:

1. Controlled Shutdown and Venting: Execute a controlled pump-down termination via the frequency converter, allowing the rotor to decelerate to rest under magnetic bearing support. Vent the pump to atmospheric pressure through the designated vent valve — never allow sudden atmospheric ingress to a spinning rotor. Isolate the pump from the vacuum chamber using the gate valve or inline isolation valve.

2. Electrical Isolation: Disconnect the frequency converter power supply and all signal cables (speed reference, fault output, bearing current feedback) before opening the pump housing. Confirm isolation with a voltage tester. Label all connectors to ensure correct reassembly.

3. Component Removal and Inspection: Remove the pump from the vacuum system following the LEYBOLD TURBOVAC 50 service manual procedure. Inspect the pump housing, stator stack, and bearing seats for secondary damage. Document findings photographically for maintenance records.

4. Installation of V50-TURBOVAC50-85406-886304-0: Install the replacement component to OEM torque specifications. Do not use thread-locking compounds on bearing-adjacent fasteners unless explicitly specified. Verify rotor freedom of movement before closing the pump housing.

5. System Reassembly and Leak Check: Reconnect all flanges with new seals, restore electrical connections, and perform a helium leak check or rough-pump leak-down test before initiating the turbo pump start sequence. Confirm foreline pressure is within the TURBOVAC 50 operating envelope before enabling the frequency converter.

6. Performance Verification: Monitor pump-down curve, ultimate pressure, and drive current during the first operational cycle. Compare against baseline records to confirm the replacement has restored system performance to specification.

Spare Parts Support FAQ

Q1: Is the V50-TURBOVAC50-85406-886304-0 compatible with all TURBOVAC 50 serial number ranges?
The component is specified to LEYBOLD TURBOVAC 50 series standards. For systems with early serial numbers or field-modified configurations, we recommend providing your pump serial number at the time of enquiry so compatibility can be confirmed against our technical records before shipment.

Q2: What pre-shipment testing is performed on this spare?
Each unit undergoes dimensional inspection and functional verification prior to dispatch. Test records are available upon request and accompany the shipment documentation. This ensures that the component arrives ready for installation without requiring incoming inspection delays on your site.

Q3: What does the 12-month warranty cover?
The 12-month warranty covers manufacturing defects and material non-conformance under normal operating conditions consistent with LEYBOLD TURBOVAC 50 application parameters. Warranty claims are supported with replacement or credit, subject to return inspection. Damage resulting from incorrect installation, contaminated process gas, or operation outside rated parameters is excluded.

Q4: Can you support long-term or blanket spare parts orders for ongoing maintenance programmes?
Yes. We support scheduled spare parts supply agreements for maintenance teams managing multiple TURBOVAC 50 units or broader LEYBOLD vacuum system fleets. Contact our technical sales team to discuss inventory holding, lead time commitments, and volume pricing structures suited to your maintenance planning cycle.


© 2026 SMARTNEXMSK. All rights reserved.
Original Source: https://smartnexmsk.com
Contact: sales@smartnexmsk.com | +86 18259474341

Request Quote WhatsApp Email