Automation Part SmartNexMSK Catalog

OPTO 22 001818K-AC24-AT Retrofit-Ready Discrete Input Module

OPTO 22 001818K-AC24-AT retrofit-ready discrete input module for G4 I/O systems. AC 24V, drop-in replacement, 12-month warranty, fast global shipping.

SKU001818K AC24 AT
BrandOPTO 22
SeriesOther series
OPTO 22 001818K AC24 AT Discrete Input Module
Model context is attached to every quote action. Use WhatsApp for urgent downtime, or Email for purchasing records.
Model checkSKU and compatibility review Quality evidencePhotos and label notes when available Export supportPacking, courier, and delivery notes
Product Information

Model Details

SKU / Model 001818K AC24 AT
Brand OPTO 22
Product Type Discrete Input Module
Series Other series
Catalog Category Business & Industrial > Automation, Control & Flow Devices > Programmable Logic Controllers
Tags AC24V Replacement, Discrete Input Module, G4 I/O, OPTO 22, PLC Retrofit
Catalog Paths

Continue from this exact model

Use the live catalog paths below to compare the same brand, product type, or series before sending your RFQ.

RFQ Intent Desk

Choose the right sourcing path for this model

Each action carries the product model and intent into the inquiry record so the sales follow-up starts with useful context.

Exact Model Quote

Use this path when the SKU, brand, quantity, and destination are already confirmed.

Start
Replacement Check

Use this path for old, obsolete, or uncertain models that need compatibility review.

Start
Quality Confirmation

Ask for label photos, packing notes, documentation, or pre-shipment checks.

Start
Urgent Dispatch

Route downtime or maintenance requests with target dispatch timing and courier country.

Start
Description

OPTO 22 001818K-AC24-AT Retrofit-Ready Discrete Input Module Overview

OPTO 22 001818K-AC24-AT Retrofit-Ready Discrete Input Module for G4 I/O Control Systems

The OPTO 22 001818K-AC24-AT is a 24VAC discrete input module engineered for the G4 I/O series rack architecture. As legacy G4-based control systems approach end-of-life or require capacity expansion, this module serves as a direct retrofit solution — preserving existing wiring infrastructure, rack mounting positions, and field device connections while restoring full I/O functionality without requiring a complete system overhaul.

Industrial facilities operating OPTO 22 G4 racks frequently encounter the challenge of sourcing discontinued or hard-to-find I/O modules. The 001818K-AC24-AT addresses this directly: it is a verified compatible replacement for earlier G4 discrete input variants operating on 24VAC field circuits, making it suitable for motor starter feedback, valve position sensing, pushbutton inputs, and relay contact monitoring in legacy control cabinets.

Upgrade Compatibility Table

Parameter Details
Module SKU 001818K-AC24-AT
Brand / Series OPTO 22 / G4 I/O Series
Module Type Discrete Input, AC 24V
Rack Interface G4 Brain Board / G4 Rack (4-slot, 8-slot, 16-slot compatible)
Communication Compatibility Compatible with SNAP PAC, Mistic, and legacy G4 brain board protocols
Replacement Candidates Earlier G4 AC24V discrete input modules; direct pin-compatible drop-in
Installation Requirement Standard G4 module slot; no additional wiring adapter required
Commissioning Notes Verify module address assignment in PAC Control or Mistic ladder; confirm field voltage at terminal block before insertion
Warranty 12 Months — covers manufacturing defects and functional failure under normal operating conditions

Retrofit Planning for Existing Automation Systems

When integrating the 001818K-AC24-AT into an existing G4 rack, the retrofit process typically begins with a physical audit of the control cabinet. Engineers should document the current slot assignments across the G4 rack — whether a 4-slot G4R4, an 8-slot G4R8, or a 16-slot G4R16 — and confirm that the brain board firmware version supports the module’s input characteristics. In many legacy installations, the G4 brain board communicates upstream to a SNAP PAC R-series controller or an older Mistic controller via RS-485 or Ethernet, and the I/O map must be verified before the replacement module is inserted.

Terminal block wiring is a critical checkpoint. The 001818K-AC24-AT uses the standard G4 two-terminal field wiring interface, accepting 24VAC from the field device. Before powering the rack, technicians should confirm that the field power supply — often a dedicated 24VAC transformer or a panel-mounted power supply module — is within specification and that no cross-wiring exists between AC and DC circuits in the same cabinet section.

In systems where the G4 rack coexists with SNAP I/O modules or SNAP PAC EB-series Ethernet brain boards, the module address table in PAC Control must be updated to reflect the restored input point. If the original module was mapped to a specific I/O unit address and point number, the replacement 001818K-AC24-AT will inherit that address automatically upon insertion — provided the brain board configuration has not been altered. For installations using PAC Display or a third-party HMI connected via OPC-DA or OPC-UA, the I/O tag database should be validated after the swap to confirm that all discrete input tags are reading correctly.

Facilities upgrading from older Mistic I/O racks to G4 architecture will find the 001818K-AC24-AT particularly useful as a transitional component. The G4 platform supports the same field wiring conventions as Mistic, reducing the need for terminal block rewiring. In parallel, engineers often source complementary components such as the OPTO 22 G4ODC5 discrete output module, G4 power supply modules, and G4 brain boards to complete a full rack rebuild. For communication-intensive upgrades, SNAP PAC EB1 or EB2 Ethernet brain boards are commonly paired with G4 racks to enable modern Ethernet/IP or SRTP protocol connectivity, replacing legacy serial links.

I/O expansion projects frequently require additional G4 analog input modules alongside discrete modules. In mixed-signal control panels — such as those managing pump stations, HVAC systems, or conveyor lines — the 001818K-AC24-AT handles the discrete feedback layer while G4 analog modules manage 4–20mA or 0–10VDC process signals. Programming cables such as the OPTO 22 USB-to-serial adapter are typically needed for on-site firmware verification and brain board configuration during commissioning.

Downtime Control During System Migration

Minimizing unplanned downtime is the primary concern during any G4 I/O module replacement. The 001818K-AC24-AT supports a hot-swap-compatible installation process when the G4 rack is de-energized at the module level — field power can often be maintained at the panel while the specific rack slot is isolated. This approach preserves control continuity for other I/O points on the same rack during the swap.

Before removing the failed or obsolete module, the original PAC Control strategy file should be backed up and the current I/O status logged. This ensures that if any address conflict or communication fault occurs after insertion of the replacement module, the engineering team can restore the prior configuration without data loss. For facilities running 24/7 operations, it is advisable to pre-stage the 001818K-AC24-AT in the control room, perform a bench-level functional test using a 24VAC test source, and confirm LED indicator behavior before scheduling the live swap during a planned maintenance window.

Post-installation, the commissioning checklist should include: confirmation of input LED status under live field signal, verification of the corresponding tag value in PAC Control or the SCADA system, and a review of the HMI faceplate to ensure the discrete input point is displaying correctly. If the system uses alarm management tied to the input point, alarm inhibit should be applied during the swap and re-enabled only after the point is confirmed healthy. All replacement activities are covered under our 12-month warranty, providing assurance that the module will perform to specification from day one of installation.

Retrofit Support FAQ

Q1: Is the 001818K-AC24-AT a direct drop-in replacement for my existing G4 discrete input module?
Yes. The 001818K-AC24-AT is pin-compatible with standard G4 module slots and accepts 24VAC field wiring using the same two-terminal interface as earlier G4 discrete input variants. No wiring adapter or bracket modification is required. Confirm the slot address assignment in your brain board configuration before insertion.

Q2: What commissioning steps are required after installing the replacement module?
After physical installation, apply field power and verify the module’s input LED activates under a live 24VAC signal. In PAC Control, confirm the corresponding I/O point reads the correct state. If using PAC Display or a third-party HMI, validate that the tag value updates correctly. For Mistic-based systems, verify the I/O unit address has not shifted due to rack reconfiguration.

Q3: Can this module be used in a mixed G4 and SNAP I/O rack environment?
The 001818K-AC24-AT is designed exclusively for G4 rack slots and is not physically compatible with SNAP I/O mounting rails. However, it can coexist in the same control cabinet alongside SNAP PAC brain boards and SNAP I/O modules, provided each rack type is independently powered and addressed within the PAC Control strategy.

Q4: What does the 12-month warranty cover?
Our 12-month warranty covers manufacturing defects and functional failure under normal operating conditions from the date of shipment. Each unit undergoes pre-shipment functional testing to verify input response, LED operation, and terminal integrity. Warranty claims are processed with priority turnaround to minimize impact on your production schedule.