PHOENIX CONTACT QUINT-PS/1AC/48DC/5 2866679 Maintenance-Ready Spare for QUINT Series Automation
The PHOENIX CONTACT QUINT-PS/1AC/48DC/5 (Part No. 2866679) is a single-phase, 48 VDC / 5 A DIN-rail mounted power supply unit engineered for continuous-duty industrial automation environments. As a maintenance-ready original spare, this unit is stocked, tested, and dispatched to support rapid fault recovery in QUINT Series control panels, PLC cabinets, and distributed I/O enclosures. Whether you are managing a planned shutdown, responding to an unplanned trip, or building a strategic spare parts buffer, the QUINT-PS/1AC/48DC/5 2866679 delivers the electrical performance and form-factor compatibility required to restore system availability with minimal downtime.
For maintenance engineers and procurement engineers operating in process automation, machine building, or infrastructure control, this power supply is a critical node in the 24 VDC and 48 VDC distribution architecture. Its QUINT Active Boost technology ensures reliable load startup even under capacitive or motor-driven loads, and its integrated SFB (Selective Fuse Breaking) function enables precise fault isolation without tripping upstream protection devices — a key advantage during live-panel diagnostics.
Spare Maintenance Table
| Parameter | Specification |
|---|---|
| Part Number / SKU | QUINT-PS/1AC/48DC/5 | 2866679 |
| Brand | PHOENIX CONTACT |
| Series | QUINT Power |
| Input Voltage | 85–264 VAC (1-phase) / 90–350 VDC |
| Output Voltage | 48 VDC (adjustable 45–56 VDC) |
| Output Current | 5 A nominal; up to 10 A boost (QUINT Active Boost) |
| Output Power | 240 W |
| Mounting | DIN rail (EN 60715 TH 35) |
| Protection Class | IP20 |
| Operating Temperature | -25 °C to +70 °C |
| Certifications | UL, cUL, CE, GL, DNV, ATEX Zone 2 |
| Dimensions (W × H × D) | Approx. 55 × 130 × 125 mm |
| Weight | 1,210 g |
| Country of Origin | Germany |
| Series Compatibility | QUINT Power family; replaces legacy QUINT-PS/1AC/48DC/5 variants |
| Application Environment | Industrial control panels, PLC cabinets, DCS marshalling racks, field enclosures |
| Maintenance Recommendation | Inspect output terminals, load wiring, and signalling contacts every 12 months or after any overcurrent event |
| Warranty | 12 Months — tested and verified before dispatch |
Maintenance Planning for Continuous Operation
When the QUINT-PS/1AC/48DC/5 2866679 is identified as a fault source or scheduled for preventive replacement, a thorough cabinet inspection is essential to prevent repeat failures and ensure system stability. Maintenance engineers should treat this power supply replacement as an opportunity to audit the entire 48 VDC distribution loop.
Begin by verifying the upstream AC supply integrity — check the input fuse or miniature circuit breaker (MCB) feeding the PSU, and confirm that input voltage is within the 85–264 VAC operating range. Inspect the input terminal block and wiring for signs of thermal stress, loose connections, or insulation degradation. On the DC output side, examine the load distribution terminal strips and any downstream fuse holders or electronic circuit breakers protecting individual 48 VDC branch circuits.
If the control cabinet also houses a PHOENIX CONTACT QUINT-PS/1AC/24DC/10 or QUINT-PS/3AC/24DC/20 for parallel 24 VDC rails, inspect those units simultaneously — shared cabinet thermal environments mean that a failed 48 VDC PSU often signals thermal stress on adjacent power modules. Check the QUINT DIODE redundancy module if a redundant PSU configuration is in use, as diode module degradation can mask true PSU output faults.
For PLC and DCS I/O systems powered from this 48 VDC rail, verify the health of connected PHOENIX CONTACT IB IL 48 VDC inline I/O modules, remote I/O terminal bases, and any 48 VDC-powered solenoid valve drivers or field transmitters. Signal isolators and loop-powered transmitters operating on 48 VDC loops should be checked for correct loop current and isolation integrity. If the system includes HART or PROFIBUS PA field devices, confirm that segment couplers and power conditioners are receiving stable supply voltage post-replacement.
Communication modules — particularly PROFIBUS DP/PA links, MODBUS RTU converters, or EtherNet/IP adapters — should be power-cycled in a controlled sequence after PSU replacement to ensure clean re-initialisation. HMI panels and operator terminals connected to the same cabinet bus should be verified for correct startup and display of live process values. Relay output modules and safety relay units in the same enclosure should be functionally tested to confirm correct coil energisation at 48 VDC.
Finally, review the cabinet’s thermal management: clean or replace cabinet fan filters, verify thermostat setpoints, and confirm that the replacement QUINT-PS/1AC/48DC/5 2866679 is seated correctly on the DIN rail with adequate clearance for convective cooling. A complete spare parts kit for this cabinet should also include a set of PHOENIX CONTACT push-in terminal blocks, spare fuse elements for the output branch circuits, and a replacement signalling contact module if the existing unit has accumulated fault-log events.
Site Replacement Workflow
Step 1 — Isolation and Safety: De-energise the AC input feed to the PSU via the upstream MCB or isolator. Confirm absence of voltage on input terminals using a calibrated multimeter. Apply LOTO (Lockout/Tagout) per site safety procedures.
Step 2 — Documentation: Photograph the existing wiring layout, terminal labelling, and DIN rail position before disconnection. Record the output voltage setpoint from the existing unit’s adjustment potentiometer if it has been trimmed from factory default.
Step 3 — Removal: Disconnect output load wiring from the DC output terminals, then disconnect AC input wiring. Release the DIN rail locking tab and slide the unit off the rail. Retain the old unit for failure analysis if required by your maintenance management system.
Step 4 — Installation of QUINT-PS/1AC/48DC/5 2866679: Clip the replacement unit onto the DIN rail. Reconnect AC input wiring to L, N, and PE terminals per the original wiring diagram. Reconnect DC output wiring to + and – terminals. If the output voltage was previously adjusted, set the replacement unit to the same trimmed value before energisation.
Step 5 — Commissioning: Re-energise the AC input. Measure DC output voltage at the PSU terminals and at the furthest load point to confirm voltage drop is within acceptable limits. Verify the green OK LED is illuminated and no fault signals are active on the signalling contact output. Restore PLC, DCS, and HMI systems in the correct sequence per your system restart procedure.
Step 6 — Documentation Close-Out: Update the maintenance management system (CMMS) with the replacement date, new unit serial number, and any observations. Schedule the next inspection interval — typically 12 months or per your site’s preventive maintenance plan.
This workflow is compatible with direct replacement of legacy QUINT-PS/1AC/48DC/5 variants and does not require firmware updates, parameter re-configuration, or bus address changes, making it one of the lowest-risk PSU replacements in the QUINT Power family.
Spare Parts Support FAQ
Q1: Is the QUINT-PS/1AC/48DC/5 2866679 a direct drop-in replacement for older QUINT 48 VDC power supplies?
Yes. The 2866679 maintains the same DIN rail footprint, terminal layout, and output specification as earlier QUINT-PS/1AC/48DC/5 production runs. No mechanical or wiring modifications are required for direct substitution in existing QUINT Series control panels.
Q2: What pre-shipment testing is performed on this spare?
Each unit undergoes output voltage verification, load regulation testing, and visual inspection before dispatch. Units are shipped with original manufacturer packaging where available, or in anti-static protective packaging with a test-passed label. A 12-month warranty is provided from the date of shipment.
Q3: How should this spare be stored if not immediately installed?
Store in a dry, temperature-controlled environment (recommended: 15–35 °C, relative humidity <75% non-condensing). Keep in original or protective packaging. Avoid storage near strong magnetic fields or corrosive atmospheres. Inspect and re-test if stored for more than 24 months before installation.
Q4: Can long-term supply be arranged for multi-site maintenance programmes?
Yes. We support blanket order arrangements and consignment stock agreements for maintenance teams managing multiple sites or large installed bases of QUINT Series equipment. Contact our team to discuss volume pricing, lead time commitments, and dedicated stock reservation for your maintenance programme.