Automation Part • SmartNexMSK Catalog

Rexroth 1070089509-GA1 Retrofit AC Servo for MSK

Rexroth 1070089509-GA1 retrofit-ready AC servo motor for MSK Series. Drop-in replacement, protocol-compatible, 12-month warranty. In stock.

SKU / Model 1070089509-GA1
Brand Bosch Rexroth
Product Type AC Servo Motor
Country of Origin DE
Catalog Category Business & Industrial > Automation, Control & Flow Devices
Model checkSKU and compatibility Quality evidencePhotos on request Export supportPacking and delivery
Description

Rexroth 1070089509-GA1 Retrofit AC Servo for MSK Overview

Rexroth 1070089509-GA1 Retrofit-Ready AC Servo Motor for MSK Series Control Systems

The Bosch Rexroth 1070089509-GA1 is a high-performance AC servo motor engineered for seamless integration into MSK Series drive and control architectures. As legacy servo systems reach end-of-life or become increasingly difficult to source, the 1070089509-GA1 provides a verified retrofit path that preserves existing wiring layouts, encoder feedback interfaces, and drive communication protocols — minimizing engineering rework and unplanned downtime during system modernization.

This unit is fully compatible with Rexroth IndraDrive series drive controllers, including the HCS and HMS families, which are commonly paired with MSK motors in multi-axis motion control cabinets. When replacing an aging MSK servo motor, engineers must verify the motor feedback type — whether resolver, single-turn EnDat, or multi-turn EnDat — to ensure the replacement unit matches the existing IndraDrive parameter set. The 1070089509-GA1 ships with factory-configured feedback that aligns with standard MSK Series drive parameterization, reducing commissioning time significantly.

For retrofit projects involving Rexroth IndraControl L or IndraControl V controller platforms, the 1070089509-GA1 integrates directly without requiring firmware updates to the motion controller, provided the axis parameters stored in the IndraDrive C or IndraDrive M are backed up and restored correctly. Engineers should use the IndraWorks DS commissioning software to export the axis parameter set from the outgoing drive before swapping the motor, ensuring that current limits, velocity loop gains, and position feedback resolution are preserved across the replacement.

Upgrade Compatibility Table

Parameter Details
SKU / Part Number 1070089509-GA1
Brand Bosch Rexroth
Series MSK Series AC Servo Motor
Compatible Drive Controllers IndraDrive HCS, HMS, HMD; IndraDrive C / M families
Feedback Interface EnDat (single-turn / multi-turn) or Resolver — confirm before ordering
Mounting / Flange IEC standard flange; confirm shaft diameter and keyway with existing coupling
Communication Protocol SERCOS II / SERCOS III via IndraDrive; verify fieldbus node address
Replacement Recommendation Direct retrofit for MSK Series; parameter backup required before swap
Commissioning Tool IndraWorks DS / IndraWorks Engineering
Commissioning Focus Axis parameter restore, encoder alignment, current loop tuning
Origin Germany
Warranty 12 Months

Retrofit Planning for Existing Automation Systems

A successful retrofit of the 1070089509-GA1 into an existing MSK Series installation requires a structured pre-replacement audit. Begin by documenting the current motor nameplate data, including rated torque, rated speed, and encoder resolution, then cross-reference these values against the IndraDrive axis parameter file. In multi-axis systems where several MSK motors share a common DC bus — supplied by an HCS02 or HCS03 power supply unit — confirm that the total regenerative load remains within the power supply’s rated capacity after the motor swap.

Terminal wiring should be verified against the original motor connection diagram. The 1070089509-GA1 uses a standard Rexroth MSK connector layout for both the power cable (motor phases U, V, W and PE) and the feedback cable. If the existing installation uses Rexroth INK series motor cables, these are typically reusable without modification, which eliminates a significant source of retrofit cost and delay. Confirm cable shielding continuity and grounding at the control cabinet entry point before energizing the replacement motor.

For systems that also include Rexroth IndraDrive Mi (integrated drive-motor) units on the same machine, ensure that the SERCOS ring or EtherCAT segment addressing is not disrupted during the motor replacement. The node address of the replaced axis must be reassigned correctly in the IndraControl L controller’s axis configuration. If the machine also uses Rexroth IndraMotion MLC or MLD motion logic controllers, the axis mapping in the PLC program must be validated after the parameter restore to confirm that cam tables, electronic gearing ratios, and position reference points remain intact.

Control cabinets housing MSK Series drives frequently also contain Rexroth HMI terminals such as the IndraControl VCP or VEP series. After the motor replacement, verify that all HMI diagnostic screens displaying axis status, torque utilization, and fault codes are reading correctly from the restored drive parameters. Any axis-specific alarm thresholds stored in the HMI project should also be reviewed to confirm they remain appropriate for the replacement motor’s rated values.

Where the retrofit involves migrating from an older SERCOS II ring to a SERCOS III or EtherCAT topology — a common upgrade path when modernizing legacy Rexroth systems — the 1070089509-GA1 supports this transition when paired with a compatible IndraDrive C or IndraDrive M controller. This migration also typically involves replacing the Rexroth CSB01 or CSE02 SERCOS interface cards in the controller rack with updated communication modules, and updating the IndraWorks project to reflect the new fieldbus topology.

Downtime Control During System Migration

Minimizing production downtime during an MSK Series servo motor replacement requires careful pre-staging and a disciplined changeover sequence. Before the scheduled maintenance window, prepare the 1070089509-GA1 by verifying its feedback type, shaft dimensions, and connector pinout against the unit being replaced. Pre-load the axis parameter file into a laptop running IndraWorks DS so that the parameter restore can be executed immediately after the new motor is mechanically installed and wired.

During the changeover, follow a defined sequence: de-energize the axis, lock out the IndraDrive controller, disconnect the motor power and feedback cables, remove the outgoing MSK motor, install the 1070089509-GA1, reconnect cables in reverse order, and restore power. The IndraDrive controller will perform an automatic encoder identification sequence on first power-up with the new motor — this process typically completes within 60 seconds and does not require manual intervention if the axis parameters have been correctly restored.

To protect the original PLC program logic stored in the IndraControl L or IndraMotion MLC controller, do not perform a full controller reset during the motor swap. The axis parameter restore in IndraWorks DS operates at the drive level only and does not affect the PLC application program, cam profiles, or motion sequences stored in the controller. This separation of drive parameters from controller logic is a key advantage of the Rexroth IndraDrive architecture and allows motor replacements to be completed without re-commissioning the entire machine.

After the motor is installed and parameters are restored, perform a controlled low-speed jog test before returning the axis to automatic mode. Verify encoder feedback direction, confirm that the axis homes correctly to its reference position, and check that torque limits are not being exceeded at the application’s normal operating speeds. Document the completed replacement in the machine maintenance log, including the new motor serial number and the date of installation, to support future warranty claims and spare parts planning.

Retrofit Support FAQ

Q: Is the Rexroth 1070089509-GA1 a direct drop-in replacement for my existing MSK Series motor?
A: In most MSK Series installations, yes — provided the feedback type (EnDat or resolver), shaft configuration, and flange size match the outgoing unit. We recommend confirming the motor’s full nameplate data and the IndraDrive axis parameter file before placing your order. Our technical team can assist with cross-referencing if you provide the existing motor’s part number suffix.

Q: What commissioning steps are required after installing the 1070089509-GA1?
A: The primary commissioning steps are: (1) restore the axis parameter file to the IndraDrive controller using IndraWorks DS, (2) allow the drive to complete its automatic encoder identification sequence, (3) verify feedback direction and homing behavior at low speed, and (4) confirm torque and velocity loop performance under load. For systems using SERCOS III or EtherCAT, also verify that the axis node address is correctly assigned in the controller configuration.

Q: Can I reuse my existing Rexroth INK series motor cables with the 1070089509-GA1?
A: Yes, in the majority of cases. The 1070089509-GA1 uses the standard Rexroth MSK connector layout, which is compatible with INK series power and feedback cables. Inspect the cable connectors and shielding for wear before reuse, and confirm that the cable’s current rating is appropriate for the replacement motor’s rated current.

Q: What does the 12-month warranty cover, and how is it supported?
A: The 1070089509-GA1 carries a 12-month warranty covering manufacturing defects and functional failures under normal operating conditions. Each unit undergoes pre-shipment functional testing before dispatch. In the event of a warranty claim, contact our technical support team with the motor serial number, installation date, and a description of the fault. Replacement or repair will be arranged promptly to minimize your production impact.

© 2026 SMARTNEXMSK. All rights reserved.
Original Source: https://smartnexmsk.com
Contact: [email protected] | +86 18259474341

Catalog Paths

Continue from this exact model

Use the live catalog paths below to compare the same brand, product type, or series before sending your RFQ.

RFQ Intent Desk

Choose the right sourcing path for this model

Each action carries the product model and intent into the inquiry record so the sales follow-up starts with useful context.

Exact Model Quote

Use this path when the SKU, brand, quantity, and destination are already confirmed.

Start
Replacement Check

Use this path for old, obsolete, or uncertain models that need compatibility review.

Start
Quality Confirmation

Ask for label photos, packing notes, documentation, or pre-shipment checks.

Start
Urgent Dispatch

Route downtime or maintenance requests with target dispatch timing and courier country.

Start
Request Quote WhatsApp Email