Automation Part • SmartNexMSK Catalog

Schneider 172PNN26022 Retrofit-Ready Modbus Plus Adaptor

Schneider 172PNN26022 Momentum Series Modbus Plus adaptor. Drop-in retrofit replacement for legacy control systems. Compatible with Quantum & Premium PLCs.

SKU / Model 172PNN26022
Brand Schneider Electric
Product Type Network Communication Adaptor
Country of Origin FR
Catalog Category Business & Industrial > Automation, Control & Flow Devices > Programmable Logic Controllers
Model checkSKU and compatibility Quality evidencePhotos on request Export supportPacking and delivery
Description

Schneider 172PNN26022 Retrofit-Ready Modbus Plus Adaptor Overview

Schneider 172PNN26022 Retrofit-Ready Modbus Plus Adaptor for Momentum Control Systems

The Schneider Electric 172PNN26022 is a Modbus Plus Network Adaptor designed for the Momentum Series automation platform — one of the most widely deployed modular PLC architectures in process manufacturing, water treatment, and discrete production environments. As legacy Momentum systems approach end-of-life or require expansion, the 172PNN26022 remains a critical retrofit component that enables engineers to preserve existing Modbus Plus communication infrastructure without redesigning the entire control architecture.

Whether you are replacing a failed unit on a running production line, upgrading a control cabinet that has been in service for over a decade, or migrating a Momentum-based system to a more maintainable configuration, the 172PNN26022 provides a direct, protocol-compatible solution that minimises engineering rework and commissioning time. SMARTNEXMSK maintains verified stock of this adaptor, with each unit pre-shipment tested and backed by a 12-month warranty.

Upgrade Compatibility Table

Parameter Details
SKU / Part Number 172PNN26022
Brand / Series Schneider Electric — Momentum Series
Module Function Modbus Plus Network Communication Adaptor
Communication Protocol Modbus Plus (MB+)
Interface / Connector 9-pin DB9 Modbus Plus port; rear I/O bus connector
Backplane Compatibility Momentum M1 I/O base (170 series I/O modules)
Power Supply Requirement Supplied via Momentum I/O base; verify base power budget before installation
Replacement Guidance Direct drop-in for existing 172PNN26022 installations; confirm firmware revision if mixing with updated 170 series I/O
Commissioning Focus Node address configuration, network termination resistor status, peer-to-peer table verification
Operating Temperature 0°C to 60°C (32°F to 140°F)
Mounting DIN rail or panel mount via Momentum base
Warranty 12-Month Warranty — SMARTNEXMSK

Retrofit Planning for Existing Automation Systems

A successful retrofit of the 172PNN26022 into an existing Momentum-based control cabinet begins well before the module arrives on site. Engineers should first audit the current Modbus Plus network topology — documenting node addresses, cable routing, and termination points — to ensure the replacement adaptor is configured identically to the unit being removed. The Momentum platform uses a distributed I/O architecture where the 172PNN26022 adaptor sits atop a 170 series I/O base, such as the 170ADI34000 discrete input module or the 170ADO34000 discrete output module, and communicates upstream to a Quantum or Premium series PLC controller via the Modbus Plus trunk cable.

Before powering down the cabinet, retrieve the current peer-to-peer routing table and global data configuration from the Concept or Unity Pro programming software. These settings define how the 172PNN26022 exchanges data with other network nodes, including remote I/O drops, variable-speed drives, and operator interface panels. Losing this configuration without a backup is one of the most common causes of extended downtime during Momentum retrofits.

On the hardware side, verify that the Momentum I/O base power supply — typically a 170XTS00100 or equivalent power distribution module — can support the current draw of the replacement adaptor alongside all installed I/O modules. Check the DIN rail mounting condition and inspect the backplane bus connector for corrosion or mechanical damage before seating the new 172PNN26022. If the cabinet also contains a 170ENT11001 Ethernet TCP/IP adaptor or a 172DNA20030 DeviceNet adaptor on adjacent bases, confirm that their node addresses do not conflict with the Modbus Plus node assignment of the replacement unit.

For sites running Modicon Quantum PLCs as the Modbus Plus master, verify that the 140NOE77100 or 140CRP93200 network option module firmware is compatible with the Momentum adaptor revision being installed. In mixed-revision networks, a firmware mismatch can cause intermittent communication faults that are difficult to diagnose without a Modbus Plus traffic analyser. SMARTNEXMSK recommends requesting the firmware label from the unit prior to shipment if revision matching is critical for your application.

Programming cable access is also a retrofit consideration. If the site uses a 990NAD23000 Modbus Plus to USB programming cable or a 490NAD91115 serial programming adaptor, confirm that the laptop running Concept or Unity Pro can reach the replacement adaptor’s node address before the old unit is removed. This allows a live configuration comparison and reduces the risk of introducing parameter errors during the swap.

Downtime Control During System Migration

Minimising production downtime during a Momentum adaptor replacement requires a structured hot-swap procedure. Where the process permits a controlled shutdown, the recommended approach is to place the Modbus Plus master PLC in stop mode, remove the failed 172PNN26022, seat the replacement unit, restore the node address via the rotary switch on the adaptor face, and power up the base before returning the PLC to run mode. Total elapsed time for a prepared technician with a pre-configured replacement unit is typically under 15 minutes.

For continuous-process applications where even a brief stop is unacceptable, the 172PNN26022 supports a warm-swap approach on some Momentum base configurations. In this scenario, the Modbus Plus master continues scanning the network while the adaptor is replaced, relying on the PLC’s I/O fallback logic — configured in the Concept or Unity Pro I/O scanner — to hold last-known output states during the brief communication interruption. Confirm that your PLC program includes appropriate watchdog logic and that field devices connected to the 170 series I/O modules are in a safe state before attempting a warm swap.

After the replacement 172PNN26022 is seated and powered, verify communication restoration by checking the MS (Module Status) and NS (Network Status) LEDs on the adaptor face. A solid green MS LED and a flashing green NS LED indicate normal Modbus Plus communication. If the NS LED remains red, check network termination at both ends of the Modbus Plus trunk and confirm that no duplicate node addresses exist on the segment. SMARTNEXMSK’s pre-shipment test report, included with each unit, documents the adaptor’s communication verification results and provides a baseline for on-site commissioning comparison.

All units supplied by SMARTNEXMSK are covered by a 12-month warranty from the date of shipment. Replacement or repair support is available for units that exhibit communication faults, LED indication errors, or backplane interface failures within the warranty period. Long-term supply continuity is maintained through established sourcing channels, ensuring that Momentum-based facilities can obtain the 172PNN26022 for ongoing maintenance and spare-parts programmes.

Retrofit Support FAQ

Q1: Is the 172PNN26022 a direct drop-in replacement for the original Schneider Electric unit?
Yes. The 172PNN26022 supplied by SMARTNEXMSK is functionally and dimensionally identical to the original Schneider Electric production unit. It mounts on the same Momentum I/O base, uses the same DB9 Modbus Plus connector, and is configured using the same rotary node address switch. No wiring modifications or base changes are required for a standard replacement.

Q2: What pre-shipment testing is performed on each unit?
Each 172PNN26022 undergoes a communication function test, LED status verification, backplane connector inspection, and visual quality check before shipment. A test report is included with the unit. Units that do not pass all test criteria are not shipped.

Q3: Can this adaptor be used with both Quantum and Premium series PLC masters?
Yes. The 172PNN26022 communicates via standard Modbus Plus protocol, which is supported by Modicon Quantum PLCs (using 140NOE or 140CRP network modules) and Modicon Premium PLCs (using TSX MBP 100 or equivalent Modbus Plus interfaces). Confirm network configuration and peer-to-peer table settings in your programming software before commissioning.

Q4: What is the warranty coverage and what does it include?
SMARTNEXMSK provides a 12-month warranty from the date of shipment. The warranty covers communication failures, backplane interface defects, and LED indication faults attributable to the module itself. It does not cover damage caused by incorrect installation, overvoltage, or physical impact. Warranty claims are processed with priority turnaround to minimise impact on production schedules.


© 2026 SMARTNEXMSK. All rights reserved.
Original Source: https://smartnexmsk.com
Contact: [email protected] | +86 18259474341

Catalog Paths

Continue from this exact model

Use the live catalog paths below to compare the same brand, product type, or series before sending your RFQ.

RFQ Intent Desk

Choose the right sourcing path for this model

Each action carries the product model and intent into the inquiry record so the sales follow-up starts with useful context.

Exact Model Quote

Use this path when the SKU, brand, quantity, and destination are already confirmed.

Start
Replacement Check

Use this path for old, obsolete, or uncertain models that need compatibility review.

Start
Quality Confirmation

Ask for label photos, packing notes, documentation, or pre-shipment checks.

Start
Urgent Dispatch

Route downtime or maintenance requests with target dispatch timing and courier country.

Start
Request Quote WhatsApp Email