Schneider ATV310HU15N4 Retrofit-Ready VFD for Altivar 310 Control Systems
The Schneider Electric ATV310HU15N4 is a 1.5 kW / 2 HP three-phase 380–460 V AC variable frequency drive from the Altivar 310 series, purpose-built for pump and fan applications in industrial environments. As legacy Altivar 31 and early Altivar 310 units reach end-of-service life, the ATV310HU15N4 has become the go-to retrofit solution for engineers managing aging control cabinets, obsolete spare-parts inventories, and production lines that cannot afford extended downtime. This listing is stocked, tested, and shipped with a 12-month warranty.
Whether you are replacing a failed drive on a HVAC air-handling unit, upgrading a water-treatment pump station, or modernizing a conveyor control panel, the ATV310HU15N4 delivers a smooth migration path. Its compact book-style enclosure fits standard 35 mm DIN rail or panel-mount installations, and its terminal layout is largely compatible with earlier Altivar 31 wiring schemes, reducing rewiring labor on retrofit projects.
Upgrade Compatibility Table
| Parameter | ATV310HU15N4 (This Unit) | Typical Legacy Unit (ATV31HU15N4) |
|---|---|---|
| Power Rating | 1.5 kW / 2 HP | 1.5 kW / 2 HP |
| Supply Voltage | 3-phase 380–460 V AC ±10% | 3-phase 380–460 V AC ±10% |
| Output Current | 4.1 A (nominal) | 4.1 A (nominal) |
| Control Terminals | Screw-clamp, 0.5–1.5 mm² | Screw-clamp, 0.5–1.5 mm² |
| Communication | Modbus RTU (RJ45) native | Modbus RTU (optional card) |
| Mounting | DIN rail / panel, book-style | DIN rail / panel, book-style |
| Protection Rating | IP20 (IP31 top kit available) | IP20 |
| Replacement Recommendation | Direct drop-in for ATV31HU15N4 | — |
| Commissioning Note | Re-enter motor nameplate parameters; verify macro selection (pump/fan/general) | — |
| Warranty | 12 Months | — |
Retrofit Planning for Existing Automation Systems
A successful ATV310HU15N4 retrofit begins well before the drive arrives on site. Start by auditing the existing control cabinet: confirm that the upstream circuit breaker or fuse rating matches the drive’s input current requirements, and verify that the 24 V DC auxiliary power supply — often shared with a Modicon TM221 or TM241 logic controller — has sufficient residual capacity to power the drive’s control board and any connected I/O expansion modules.
Next, photograph and document the existing terminal wiring. The ATV310HU15N4 uses a standard Altivar terminal layout: R/L1, S/L2, T/L3 for mains input; U/T1, V/T2, W/T3 for motor output; and a dedicated PE ground bar. Analog reference signals (0–10 V or 4–20 mA) connect to AI1/AI2, while digital run/stop commands wire to DI1–DI6. If the legacy drive used a VW3A3601 Modbus communication card, the ATV310HU15N4’s built-in RJ45 Modbus RTU port eliminates that accessory entirely, simplifying the cabinet layout and reducing potential failure points.
For sites running a Modicon M340 or Premium PLC as the supervisory controller, verify the Modbus device address configured in the original drive matches the address you will program into the ATV310HU15N4 via parameter Add in the COM menu. Mismatched addresses are the single most common cause of communication faults during commissioning. If the SCADA or HMI system — such as a Magelis HMIGTO or XBTGT panel — uses pre-built Altivar 310 device templates, those templates will map directly to the ATV310HU15N4 register set without modification.
Where the existing system includes a VW3A3608 CANopen card or a VW3A3616 EtherNet/IP card on the legacy drive, plan for a protocol migration step. The ATV310HU15N4 supports optional communication cards in the same accessory slot, so a replacement VW3A3608 or VW3A3616 card can be fitted to maintain the original fieldbus topology. Confirm card firmware compatibility before ordering. For systems migrating from CANopen to Modbus RTU, update the PLC program’s communication function blocks accordingly and re-test all drive command and status word mappings before live commissioning.
I/O expansion requirements should also be reviewed. If the legacy installation used a TM3DI16 digital input module or a TM3AQ4 analog output module to extend the PLC’s I/O count for multi-drive coordination, those modules remain fully compatible with the Modicon controller platform and do not need replacement. Only the drive itself is being swapped. Ensure that any relay output wiring from the drive’s R1A/R1B/R1C fault relay is re-terminated correctly, as this signal is often wired to a safety relay or a Preventa XPSAF module for emergency-stop monitoring.
Downtime Control During System Migration
Minimizing production downtime during a drive replacement requires a structured pre-commissioning approach. Before powering down the existing system, use SoMove or EcoStruxure Machine Expert to upload and save the current drive parameter file. The ATV310HU15N4 accepts parameter restoration via the same SoMove software, allowing you to push the saved configuration to the new drive before it is installed — reducing live commissioning time to a final verification run rather than a full parameter entry session.
Schedule the physical swap during a planned maintenance window. Isolate the drive using the upstream isolator or VCCF circuit breaker, discharge the DC bus (wait a minimum of 15 minutes after power-off and verify with a voltmeter), then remove the legacy unit. Mount the ATV310HU15N4, re-terminate the power and control cables following your documented wiring photograph, and restore the Modbus address and any site-specific parameters that could not be captured in the SoMove file (such as motor thermal state).
Before returning the system to automatic mode, perform a no-load motor rotation test at low speed (5–10 Hz) to confirm correct phase sequence and motor direction. Then step through each digital input command — run forward, run reverse, fault reset — to verify PLC-to-drive communication integrity. Only after all command and feedback signals are confirmed should the system be handed back to the process control team. This structured approach consistently achieves drive replacements within a two-to-four hour maintenance window, preserving original program logic and maintaining field control continuity throughout.
Retrofit Support FAQ
Q1: Is the ATV310HU15N4 a direct replacement for the ATV31HU15N4?
Yes. The ATV310HU15N4 is the designated successor to the ATV31HU15N4. Power rating, voltage class, output current, and physical mounting dimensions are identical. Terminal designations are consistent, and the Modbus RTU communication protocol is natively supported without an additional option card. Re-enter motor nameplate data and verify the application macro selection during commissioning.
Q2: What wiring changes are required during installation?
In most cases, existing power and control cable terminations can be reused without modification. Confirm wire cross-section compatibility (0.5–1.5 mm² for control terminals, up to 4 mm² for power terminals at this rating). If the legacy drive used an external Modbus option card, that card and its wiring can be removed; connect the Modbus cable directly to the ATV310HU15N4’s built-in RJ45 port instead.
Q3: How is the unit tested before shipment?
Each ATV310HU15N4 unit undergoes a pre-shipment functional test covering power-on self-diagnostics, control terminal continuity, and Modbus communication response. Units that do not pass all test criteria are not shipped. A test record is available upon request. All units are covered by a 12-month warranty from the date of delivery.
Q4: Can the original HMI screens and SCADA tags be retained after replacement?
Yes, provided the HMI device template is based on the Altivar 310 Modbus register map. Magelis and XBTGT panels using Altivar 310 device templates will communicate with the ATV310HU15N4 without screen modifications. If the SCADA system uses custom tag addresses mapped to specific Modbus registers, verify those register addresses against the ATV310HU15N4 programming manual to confirm alignment before going live.