Schneider iC65N-2P-C16A Retrofit-Ready MCB for Acti9

Schneider iC65N-2P-C16A Acti9 2P 16A C-Curve MCB. Drop-in retrofit replacement, compatibility verified, 12-month warranty. Fast global shipping.

SKU / Model iC65N-2P-C16A
Brand Schneider Electric
Product Type Miniature Circuit Breaker
Country of Origin FR
Catalog Category Business & Industrial > Automation, Control & Flow Devices
Model checkSKU and compatibility Quality evidencePhotos on request Export supportPacking and delivery
Description

Schneider iC65N-2P-C16A Retrofit-Ready MCB for Acti9 Overview

Schneider iC65N-2P-C16A Retrofit-Ready MCB for Acti9 Control Systems

The Schneider Electric iC65N-2P-C16A is a 2-pole, 16A, C-curve miniature circuit breaker from the Acti9 series, engineered for reliable overload and short-circuit protection in industrial control panels, motor control centers, and distribution boards. As legacy iC60N and Multi9 series installations reach end-of-service life, the iC65N-2P-C16A has become the preferred drop-in retrofit solution for engineers modernizing existing switchgear without full panel redesign.

This module is fully compatible with the Acti9 iC65 DIN-rail mounting system, accepting standard 35mm DIN rail installation. Its compact 2-pole footprint integrates directly into existing Acti9 enclosures and distribution boards, eliminating the need for busbar reconfiguration or terminal block relocation. The C-curve trip characteristic (5–10× In) makes it suitable for resistive and slightly inductive loads, including PLC power supply circuits, 24VDC control transformers, and auxiliary control circuits commonly found in legacy automation panels.

Upgrade Compatibility Table

Parameter iC65N-2P-C16A (This Unit) Legacy iC60N-2P-C16A Retrofit Notes
Poles 2P 2P Direct replacement, no rewiring
Rated Current 16A 16A Identical rating, no derating required
Trip Curve C-Curve C-Curve Same protection characteristic
Breaking Capacity 6kA @ 230/400V 6kA @ 230/400V Equivalent fault interruption rating
DIN Rail Mounting 35mm standard 35mm standard No rail modification needed
Terminal Type Tunnel terminal, 1–25mm² Tunnel terminal, 1–16mm² Verify conductor cross-section; upgrade may allow larger cable
Acti9 Accessories Compatible (OF, SD, MX/MN) Partial compatibility Confirm auxiliary contact and shunt trip compatibility
Communication Compatible with Acti9 Smartlink Not supported Enables remote monitoring via Modbus/Ethernet gateway
Commissioning Plug-and-play after terminal check — Verify torque spec: 2.5 N·m on load terminals
Warranty 12-Month Warranty Included Covers manufacturing defects; tested before shipment

Retrofit Planning for Existing Automation Systems

When integrating the iC65N-2P-C16A into an existing control system, a structured retrofit plan is essential to avoid unplanned downtime and configuration errors. Begin by auditing the existing panel layout: confirm the DIN rail space available, the busbar pitch, and whether the existing Acti9 iC65 busbar comb (4-pole or 2-pole pitch) is compatible with the replacement module position.

For panels running Schneider Modicon M340 or Modicon M580 PLCs, the iC65N-2P-C16A is commonly used to protect the 24VDC power supply rail feeding BMX CPS 2000 or BMXCPS3500 power supply modules. Verify that the upstream feeder breaker — typically an iC65N-4P-C32A or iC65H-4P-C40A — provides adequate discrimination margin (minimum 1.6:1 current ratio) to ensure selective tripping.

In legacy panels using Schneider TSX Micro or TSX Premium controllers, the control transformer circuit is often protected by an older Multi9 C60N breaker. The iC65N-2P-C16A serves as a direct functional replacement in these applications, though the installer should verify terminal block spacing and confirm that the Acti9 iC65 comb busbar pitch aligns with adjacent modules such as the iC65N-2P-C6A (for instrumentation circuits) or iC65N-2P-C10A (for HMI power supply).

For systems incorporating Schneider Acti9 iEM3000 energy meters or Acti9 Smartlink SI B communication interfaces, the iC65N-2P-C16A can be monitored remotely via Modbus RTU or Modbus TCP/IP, enabling predictive maintenance and trip event logging without additional wiring. This is particularly valuable in unmanned substations or remote pump control panels where physical inspection is infrequent.

When replacing breakers in panels that also house Schneider iRLC residual current devices or Acti9 Vigi iC65 RCD blocks, confirm that the iC65N-2P-C16A is installed on the load side of the RCD and that the neutral conductor routing is preserved. Incorrect neutral routing after a breaker swap is a common commissioning error that causes nuisance tripping.

All units supplied by SMARTNEXMSK are pre-tested for mechanical operation, trip function, and terminal integrity before shipment. Each unit ships with a test report and is covered by a 12-month warranty against manufacturing defects.

Downtime Control During System Migration

Minimizing production downtime during a breaker replacement requires preparation before the panel is de-energized. Prior to shutdown, document the existing wiring layout with photographs, record all terminal torque markings, and confirm that the replacement iC65N-2P-C16A is on-site and verified against the original nameplate data.

For systems where the breaker protects a PLC power supply — such as a Modicon M340 BMX CPS 2000 — ensure that the PLC program has been backed up to the programming terminal via Unity Pro or EcoStruxure Control Expert before power is removed. If the panel includes a Schneider XBTGT or XBTGK HMI terminal, verify that the HMI project file is saved and that the communication link (typically Modbus serial or Ethernet) will be re-established automatically on power restoration.

The physical swap of the iC65N-2P-C16A takes approximately 10–15 minutes for a trained electrician: release the DIN rail clip, disconnect load and line conductors (noting polarity for 2-pole DC applications), insert the replacement module, reconnect conductors to the specified torque (2.5 N·m on load terminals, 2.5 N·m on line terminals), and verify mechanical locking. After re-energization, perform a functional test by cycling the breaker manually and confirming that downstream equipment — including the PLC, I/O modules, and field instruments — powers up correctly and that no fault indicators are active on the Acti9 Smartlink dashboard or the PLC diagnostic screen.

For critical production lines where even a 15-minute outage is unacceptable, consider a hot-standby approach: pre-wire the replacement breaker on a temporary DIN rail section and transfer load conductors one pole at a time using insulated ferrule connectors, maintaining control circuit continuity throughout the swap.

Retrofit Support FAQ

Q1: Is the iC65N-2P-C16A a direct replacement for the iC60N-2P-C16A and Multi9 C60N-2P-C16A?
Yes. The iC65N-2P-C16A is the current-generation successor to both the iC60N and Multi9 C60N in the Acti9 platform. It shares the same 2-pole, 16A, C-curve specification and 35mm DIN rail mounting. Terminal conductor range has been expanded (up to 25mm²), so verify that existing cable ferrules seat correctly in the new terminal block before final torquing.

Q2: Can I use the iC65N-2P-C16A with existing Acti9 auxiliary contacts and shunt trip accessories?
Yes, the iC65N is compatible with the full range of Acti9 iC65 accessories, including OF auxiliary contacts, SD fault signal contacts, and MX/MN shunt trip/undervoltage releases. If your existing panel uses older Multi9 accessories, these are not compatible and must be replaced with the corresponding Acti9 iC65 accessory variants.

Q3: What commissioning checks are required after installation?
After installation, verify: (1) terminal torque at 2.5 N·m for both line and load terminals; (2) correct phase/neutral assignment for 2-pole AC applications; (3) manual trip and reset function; (4) downstream equipment powers up without fault; (5) if connected to Acti9 Smartlink, confirm the module appears on the Modbus device list and trip status reads “Closed”. For DC applications, confirm polarity orientation as the iC65N is not polarity-sensitive but downstream equipment may be.

Q4: What does the 12-month warranty cover, and how is it claimed?
The 12-month warranty covers manufacturing defects, including mechanical trip failure, terminal defects, and housing integrity. It does not cover damage from incorrect installation, overcurrent events beyond rated breaking capacity, or environmental exposure beyond IP20 rating. To claim warranty, contact SMARTNEXMSK with the order reference and a description of the fault. Replacement units are dispatched within 3 business days of fault confirmation.


© 2026 SMARTNEXMSK. All rights reserved.
Original Source: https://smartnexmsk.com
Contact: [email protected] | +86 18259474341

Catalog Paths

Continue from this exact model

Use the live catalog paths below to compare the same brand, product type, or series before sending your RFQ.

RFQ Intent Desk

Choose the right sourcing path for this model

Each action carries the product model and intent into the inquiry record so the sales follow-up starts with useful context.

Exact Model Quote

Use this path when the SKU, brand, quantity, and destination are already confirmed.

Start
Replacement Check

Use this path for old, obsolete, or uncertain models that need compatibility review.

Start
Quality Confirmation

Ask for label photos, packing notes, documentation, or pre-shipment checks.

Start
Urgent Dispatch

Route downtime or maintenance requests with target dispatch timing and courier country.

Start
Request Quote WhatsApp Email