Schneider TSXP4720 Retrofit-Ready Processor for TSX Premium Control Systems
The Schneider Electric TSXP4720 is a high-performance CPU module engineered for the TSX Premium programmable logic controller platform. As legacy automation infrastructure ages and original equipment manufacturers discontinue support for older processor variants, the TSXP4720 has become a critical retrofit and replacement component for facilities operating TSX Premium-based control systems across manufacturing, utilities, water treatment, and process industries. Whether you are replacing a failed unit, upgrading processing capacity, or migrating from an end-of-life TSX Micro or Modicon Quantum segment, the TSXP4720 delivers the compatibility and reliability your production environment demands.
Our inventory is sourced from verified industrial distributors and tested prior to shipment. Every TSXP4720 unit is covered by a 12-month warranty and ships with full documentation support to minimize your engineering risk during retrofit execution.
Upgrade Compatibility Table
| Parameter | TSXP4720 Specification | Retrofit Notes |
|---|---|---|
| Platform | TSX Premium PLC | Direct fit for TSX Premium racks; verify rack generation (TSX RKY series) |
| Backplane Interface | TSX Premium X-bus / FIPIO | Compatible with TSX RKY4, RKY6, RKY8, RKY12 racks |
| Communication Ports | Uni-Telway, Modbus RTU/ASCII, FIPIO | Replaces TSXP4710/TSXP4720A; verify terminal block wiring on COM port |
| Memory | Up to 256 KB application RAM | Backup existing PL7 Pro program before swap; confirm memory card compatibility |
| Power Consumption | Supplied via TSX PSY power supply module | Verify TSX PSY3600M or TSX PSY5500M capacity before installation |
| Programming Software | PL7 Pro / Unity Pro (via converter) | PL7 Pro v4.5+ recommended; Unity Pro requires project conversion |
| Installation | DIN-rail rack mount, hot-swap not supported | Power down rack fully before module removal; follow LOTO procedure |
| Replacement Candidates | TSXP4710, TSXP4720A, TSXP4730 | Confirm firmware version compatibility with existing I/O modules |
| Commissioning | PL7 Pro online transfer + I/O forcing test | Validate all analog and digital I/O channels post-swap |
| Warranty | 12 Months | Covers manufacturing defects; includes pre-shipment functional test report |
Retrofit Planning for Existing Automation Systems
Successful TSXP4720 retrofits begin well before the module arrives on-site. Engineers should start by auditing the existing control cabinet to document every component in the rack. A typical TSX Premium installation includes the TSX RKY8 backplane rack, one or more TSX DSY digital output modules, TSX DEY digital input modules, and TSX AEY analog input modules for process variable monitoring. The TSX PSY5500M power supply module must be verified to deliver sufficient current headroom for the TSXP4720’s processing load, particularly if additional TSX ETY Ethernet communication modules or TSX SCY serial communication modules are present in the same rack.
Before removing the legacy processor, use PL7 Pro to perform a full program upload and save the application to a secure backup location. If the site uses a TSX MFP memory card for program storage, verify that the card format is compatible with the TSXP4720 firmware. For installations that rely on FIPIO fieldbus for distributed I/O — connecting remote TSX Momentum I/O drops or Altivar drive controllers — confirm that the FIPIO master configuration and station addressing are documented and will be preserved after the processor swap.
Wiring adaptation is another critical checkpoint. The TSXP4720’s terminal block layout for the Uni-Telway RS-485 port and the auxiliary power connector must be compared against the existing cabinet wiring diagram. In many older installations, the RS-485 shielding and termination resistors were installed for a specific predecessor module; these may need adjustment to match the TSXP4720’s input impedance. Similarly, if the system communicates with an operator panel such as a Magelis XBTGT HMI terminal via Uni-Telway, the HMI driver configuration and station address must be re-validated after the processor replacement to ensure screen navigation and alarm acknowledgment functions correctly.
For sites migrating from Modbus RTU to a more modern communication architecture, the TSXP4720 supports simultaneous Uni-Telway and Modbus operation on its serial ports, providing a bridge period during which legacy Modbus-connected instruments — such as power meters, variable frequency drives, and remote I/O adapters — can continue operating while the new communication infrastructure is commissioned in parallel.
Downtime Control During System Migration
Minimizing unplanned downtime is the primary concern for any control system retrofit. A structured hot-cutover plan for the TSXP4720 replacement should include four phases: pre-shutdown preparation, controlled shutdown and swap, power-up and program restore, and I/O validation before returning to automatic mode.
During pre-shutdown preparation, use PL7 Pro’s online monitoring to capture the current state of all output forcing tables, data block values, and timer/counter presets. Export these to a commissioning record sheet. If the process allows, schedule the swap during a planned maintenance window to avoid emergency conditions. Notify all operators and confirm that the HMI system — whether a Magelis panel or a SCADA workstation connected via Ethernet — is in manual override mode before the rack is de-energized.
After installing the TSXP4720 and restoring power to the TSX PSY power supply, the processor will perform its self-diagnostic cycle. Connect the programming terminal running PL7 Pro via the terminal port or via the TSX ETY Ethernet module if network access is available. Download the backed-up application program and verify that the I/O configuration matches the physical rack layout. Use PL7 Pro’s I/O forcing function to test each digital output channel individually before releasing the system to automatic control. For analog channels connected to TSX AEY modules, verify engineering unit scaling and alarm setpoints against the process documentation.
Maintaining control continuity during the transition is achievable when the retrofit is executed with a pre-tested spare module. We recommend requesting a pre-shipment functional test report with each TSXP4720 unit, which confirms that the module has been powered, programmed with a diagnostic routine, and verified against its specification sheet before leaving our facility. This eliminates the risk of receiving a defective unit and discovering the fault only after the production line has been shut down.
Retrofit Support FAQ
Q1: Is the TSXP4720 a direct drop-in replacement for the TSXP4710 and TSXP4720A?
In most TSX Premium rack configurations, the TSXP4720 is physically and electrically compatible with the TSXP4710 and TSXP4720A slots. However, you should verify the firmware version of your existing I/O modules — particularly TSX DEY and TSX DSY series — to confirm they are supported by the TSXP4720’s operating system version. A PL7 Pro project backup and restore is required; the program is not automatically transferred from the old processor.
Q2: What commissioning steps are required after installing the TSXP4720?
After physical installation, connect PL7 Pro and download the application program. Verify the I/O configuration table matches the rack layout, confirm communication port settings for Uni-Telway and Modbus, and perform a forced I/O test on all digital and analog channels. If a Magelis HMI is connected, confirm that the HMI driver recognizes the new processor and that all screen variables are updating correctly before releasing to automatic mode.
Q3: Can the TSXP4720 support both Uni-Telway and Modbus RTU simultaneously?
Yes. The TSXP4720 supports concurrent Uni-Telway master/slave operation on one serial port and Modbus RTU/ASCII on the auxiliary port. This is particularly useful during phased migrations where legacy Modbus instruments must remain online while new Uni-Telway or FIPIO devices are being commissioned. Confirm port assignment in the PL7 Pro hardware configuration editor.
Q4: What does the 12-month warranty cover, and is a pre-shipment test report available?
Our 12-month warranty covers manufacturing defects and functional failures under normal operating conditions. Each TSXP4720 unit undergoes a pre-shipment functional test — including power-on self-test, communication port verification, and memory check — and a test report is available upon request. Warranty claims are processed with a replacement-first policy to minimize your production downtime.