Allen-Bradley 1336-BDB-SP29A Retrofit Drive Board 1336 PLUS

Allen-Bradley 1336-BDB-SP29A retrofit-ready drive board for 1336 PLUS AC drives. Drop-in replacement, 12-month warranty, compatibility verified, fast shipping.

SKU / Model 1336-BDB-SP29A 74101-169-53
Brand Allen-Bradley
Product Type AC Drive Control Board
Country of Origin US
Catalog Category Business & Industrial > Automation, Control & Flow Devices > Industrial Control Systems > Variable Frequency Drives
Model checkSKU and compatibility Quality evidencePhotos on request Export supportPacking and delivery
Description

Allen-Bradley 1336-BDB-SP29A Retrofit Drive Board 1336 PLUS Overview

Allen-Bradley 1336-BDB-SP29A Retrofit-Ready Drive Board for 1336 PLUS Control Systems

The Allen-Bradley 1336-BDB-SP29A (part number 74101-169-53) is a main drive control board engineered for the 1336 PLUS series of AC variable frequency drives. As legacy 1336 PLUS installations continue to operate across manufacturing, water treatment, HVAC, and material handling facilities worldwide, sourcing a verified replacement for this discontinued board has become a critical priority for maintenance engineers and system integrators. This board serves as a direct retrofit solution, enabling facilities to restore full drive functionality without replacing the entire drive chassis or reengineering the control cabinet.

The 1336-BDB-SP29A interfaces directly with the 1336 PLUS drive’s internal backplane, maintaining compatibility with the existing power structure, gate driver circuitry, and I/O terminal assignments. Engineers undertaking a retrofit should verify the drive’s firmware revision and cross-reference the board’s hardware revision code before installation. The 74101-169-53 sub-assembly designation confirms the specific board variant, which is critical when ordering to avoid receiving an incompatible revision that may require additional parameter reconfiguration or firmware flashing via a 1336-MOD-L502 programming module.

Before swapping the 1336-BDB-SP29A, technicians should document all drive parameters stored in the 1336 PLUS parameter table — particularly acceleration/deceleration ramps, current limit settings, speed reference scaling, and fault log history. These values are typically backed up using a DriveExplorer or DriveExecutive software session over the 1203-USB or 1203-GU6 DPI-to-USB communication adapter. Retaining this data ensures that after board replacement, the drive can be restored to its pre-fault operating state without requiring a full recommissioning cycle from the PLC program side.

Power supply integrity is the first checkpoint in any 1336 PLUS retrofit. The internal 24VDC logic supply, derived from the drive’s switch-mode power supply board, must be within tolerance before the new 1336-BDB-SP29A is energized. A failed or marginal power supply can damage a new control board within minutes of power-up. Technicians should also inspect the DC bus capacitor bank for bulging or leakage, as degraded capacitors are a common root cause of control board failures in aging 1336 PLUS drives. If the capacitor bank shows signs of wear, replacing it alongside the 1336-BDB-SP29A is strongly recommended to prevent repeat failures.

Terminal wiring compatibility is straightforward for most 1336 PLUS installations. The TB1 and TB2 terminal blocks retain their standard pinout across the affected drive ratings, meaning analog speed reference inputs (0–10V or 4–20mA), digital start/stop commands, fault relay outputs, and encoder feedback signals can be reconnected without rewiring. However, if the original installation used a 1336-MOD-L501 or 1336-MOD-L502 option board for DeviceNet or Remote I/O communication, the option board must be carefully reseated after the main board replacement to restore network communication with the upstream ControlLogix or SLC 500 controller.

Upgrade Compatibility Table

Parameter Details
Compatible Drive Series Allen-Bradley 1336 PLUS (1336S, 1336 PLUS II)
Part Number 1336-BDB-SP29A / 74101-169-53
Board Function Main Drive Control Board
Backplane Interface Direct plug-in to 1336 PLUS internal backplane
Communication Compatibility DeviceNet (1336-MOD-L501), Remote I/O (1336-MOD-L502), DPI
Terminal Wiring TB1/TB2 standard pinout retained; no rewiring required
Programming Interface Compatible with DriveExplorer / DriveExecutive via 1203-USB or 1203-GU6
Installation Requirement Verify firmware revision and hardware revision code before installation
Recommended Pre-checks 24VDC logic supply, DC bus capacitor bank, option board seating
Retrofit Scope Drop-in board replacement; no chassis modification required
Warranty 12-Month Warranty from date of shipment

Retrofit Planning for Existing Automation Systems

A successful 1336 PLUS retrofit begins well before the drive is de-energized. The maintenance team should gather the drive’s full nameplate data, including voltage class, horsepower rating, and catalog suffix, to confirm that the 1336-BDB-SP29A is the correct board for the specific drive variant in question. Drives in the 1336 PLUS family span a wide range of power ratings, and the control board revision may differ between low-horsepower and high-horsepower frames.

In multi-drive control cabinets, the 1336 PLUS often operates alongside companion components including the 1336-MOD-L501 DeviceNet adapter, 1336-MOD-L502 Remote I/O adapter, and 1336-GM1 or 1336-GM2 operator interface modules. These option boards and HMI panels must be carefully removed and catalogued before the main board is extracted. The 1336 PLUS chassis also commonly shares a control cabinet with a 1746 SLC 500 rack or a 1756 ControlLogix chassis, and the drive’s network node address must be preserved to avoid address conflicts on the DeviceNet or Remote I/O network after restart.

For facilities running Rockwell Automation’s RSLogix 500 or RSLogix 5000 programming environment, the drive’s I/O image table mapping should be exported and saved before the retrofit. This ensures that after the 1336-BDB-SP29A is installed and the drive is re-networked, the PLC program’s drive status bits, fault codes, speed feedback words, and command reference registers continue to map correctly without requiring ladder logic edits. In some cases, a 1747-SDN DeviceNet scanner card in the SLC 500 rack or a 1756-DNB DeviceNet bridge module in the ControlLogix chassis may need a brief re-scan to recognize the restored drive node.

Facilities that have integrated the 1336 PLUS with a PanelView 550 or PanelView 600 HMI terminal should also verify that the HMI screen tags referencing drive speed, current, and fault status remain valid after the board swap. In most cases, the HMI communication is unaffected by a control board replacement, but a cold restart of the HMI terminal after drive power-up is recommended to flush any cached fault states from the display.

Downtime Control During System Migration

Minimizing unplanned downtime is the primary concern when replacing a 1336-BDB-SP29A in a live production environment. The recommended approach is to pre-stage the replacement board in advance, performing a bench-level inspection and continuity check before the scheduled maintenance window. All drive parameters should be backed up to a laptop running DriveExplorer software at least 24 hours before the swap, so that if the backup session fails, there is time to retry before the maintenance window opens.

During the board swap, the drive must be fully de-energized and the DC bus must be discharged — typically a minimum of 5 minutes after main power removal, confirmed by measuring bus voltage with a calibrated meter. The 1336-BDB-SP29A is secured by a set of captive screws and a ribbon cable connector; both must be handled carefully to avoid damaging the backplane connector pins. After the new board is seated and secured, all option boards should be reinstalled before power is applied.

On first power-up after board replacement, the drive will typically display a “Parameter Default” or “Checksum Fault” condition, indicating that the new board’s non-volatile memory does not yet contain the site-specific parameter set. This is expected behavior. The saved parameter file should be downloaded immediately using DriveExplorer or DriveExecutive before any run command is issued. Once parameters are restored, a no-load test run at low speed (5–10 Hz) should be performed to confirm that the drive responds correctly to speed reference and start/stop commands before the motor is reconnected to the load. This staged commissioning approach protects both the new board and the connected mechanical equipment, and ensures that the control system — whether a SLC 500, ControlLogix, or standalone operator station — sees the drive return to its expected operating state without triggering upstream fault logic.

Retrofit Support FAQ

Q: Is the 1336-BDB-SP29A a direct drop-in replacement for the original board in my 1336 PLUS drive?
A: Yes, for the applicable drive variants. The 1336-BDB-SP29A (74101-169-53) is designed as a direct replacement for the main control board in compatible 1336 PLUS drives. Confirm your drive’s catalog number and existing board revision code before ordering to ensure hardware compatibility.

Q: Will I need to reconfigure my DeviceNet or Remote I/O communication after replacing the board?
A: In most cases, no. If the drive’s node address and baud rate settings are restored via parameter download after board replacement, the 1336-MOD-L501 or 1336-MOD-L502 option board will resume communication with the upstream scanner (1747-SDN or 1756-DNB) without requiring network reconfiguration. A brief re-scan of the DeviceNet network from the scanner module is recommended as a precaution.

Q: What pre-shipment testing is performed on the 1336-BDB-SP29A?
A: Each board undergoes functional verification and continuity testing prior to shipment. Units are inspected for physical damage, connector integrity, and component condition. All boards are shipped with protective anti-static packaging and include a 12-month warranty from the date of shipment covering defects in materials and workmanship.

Q: What is the warranty coverage and what does it include?
A: The 1336-BDB-SP29A carries a 12-month warranty from the date of shipment. The warranty covers manufacturing defects and component failures under normal operating conditions. It does not cover damage resulting from incorrect installation, overvoltage events, or failure to observe proper ESD handling procedures. Our technical support team is available to assist with installation questions and compatibility verification throughout the warranty period.


© 2026 SMARTNEXMSK. All rights reserved.
Original Source: https://smartnexmsk.com
Contact: [email protected] | +86 18259474341

Catalog Paths

Continue from this exact model

Use the live catalog paths below to compare the same brand, product type, or series before sending your RFQ.

RFQ Intent Desk

Choose the right sourcing path for this model

Each action carries the product model and intent into the inquiry record so the sales follow-up starts with useful context.

Exact Model Quote

Use this path when the SKU, brand, quantity, and destination are already confirmed.

Start
Replacement Check

Use this path for old, obsolete, or uncertain models that need compatibility review.

Start
Quality Confirmation

Ask for label photos, packing notes, documentation, or pre-shipment checks.

Start
Urgent Dispatch

Route downtime or maintenance requests with target dispatch timing and courier country.

Start
Request Quote WhatsApp Email