Allen-Bradley 1336-BDB-SP5C Spare for 1336 PLUS Automation: Spare Replacement & Industrial Downtime Risk Control
The Allen-Bradley 1336-BDB-SP5C is an original drive control PC board designed for the 1336 PLUS series AC variable frequency drives. As a critical spare part in industrial automation environments, this board governs the core control logic of the drive — managing PWM output, fault diagnostics, parameter storage, and communication with upstream PLC or DCS systems. When this board fails, the entire drive becomes inoperable, leading to unplanned production downtime that can cost thousands per hour in process industries.
Sourced as an original Allen-Bradley component, the 1336-BDB-SP5C is fully tested prior to shipment and backed by a 12-month warranty. It is suitable for direct replacement in 1336 PLUS drive cabinets without firmware re-flashing in most standard configurations. Maintenance engineers and procurement teams managing aging 1336 PLUS installations will find this board essential for both emergency response and planned spare inventory.
Spare Maintenance Table
| Parameter | Specification / Detail |
|---|---|
| Part Number / SKU | 1336-BDB-SP5C |
| Brand | Allen-Bradley (Rockwell Automation) |
| Compatible Series | 1336 PLUS AC Variable Frequency Drive |
| Component Type | Drive Control PC Board |
| Function | PWM control logic, fault diagnostics, parameter storage, drive-PLC communication |
| Voltage Class | Per 1336 PLUS drive rating (200–600V AC class) |
| Communication Interface | Compatible with 1336 PLUS onboard I/O and optional DPI/SCANport adapters |
| Installation | Direct board swap; observe ESD precautions; verify firmware revision compatibility |
| Application Environment | Industrial control cabinets, process automation, motor control centers (MCC) |
| Condition | Original spare; fully tested before shipment |
| Maintenance Recommendation | Inspect annually; replace proactively at first sign of fault codes F002, F005, F048 |
| Origin | United States |
| Warranty | 12 Months |
Maintenance Planning for Continuous Operation
When a 1336-BDB-SP5C control board fails or is flagged during routine inspection, maintenance engineers should treat the event as a system-level review opportunity rather than an isolated component swap. The 1336 PLUS drive operates within a broader electrical ecosystem, and a board failure often signals stress on adjacent components.
Begin by inspecting the 1336 PLUS power supply board (such as the 1336-PB series) for signs of capacitor bulge, voltage ripple, or thermal discoloration — a degraded power supply is a leading cause of control board stress. Next, verify the integrity of the gate driver board and IGBT module; a shorted output transistor can back-feed damaging voltage spikes into the control board.
Check all terminal block connections on the I/O wiring harness. Loose or corroded terminals on the analog input (0–10V / 4–20mA speed reference) or digital input (Run, Stop, Fault Reset) circuits can cause intermittent faults that are misdiagnosed as board failures. Inspect the 24VDC control power supply feeding the drive’s logic section — voltage sag below 21V will cause erratic board behavior.
If the drive uses a 1336-GM1 or 1336-MOD-C communication adapter (SCANport or DeviceNet), verify that the adapter firmware and node address are intact after board replacement, as some configurations store communication parameters on the control board itself. For drives integrated into a ControlLogix or CompactLogix PLC system via DeviceNet or EtherNet/IP, re-verify the drive’s I/O mapping in RSLogix 5000 or Studio 5000 after the swap.
Maintenance planners should also stock 1336-BDB-SP5C alongside complementary spares: a replacement keypad / HMI panel (1336-PB-SP2) for parameter backup and fault readout, signal isolators on the analog reference circuit to prevent ground loop interference, and DIN rail fuse holders with 2A control fuses protecting the 24VDC logic supply. For sites running multiple 1336 PLUS drives, a single spare board covers the entire fleet — a cost-effective inventory strategy for facilities with 5 or more drives of this series.
Site Replacement Workflow
Step 1 — Pre-replacement documentation: Before powering down, record all drive parameters using the 1336 PLUS keypad or DriveExplorer software. Save the parameter file to a laptop or USB adapter. This eliminates re-commissioning time after board swap.
Step 2 — Safe isolation: Open the MCC breaker feeding the drive. Apply LOTO (Lockout/Tagout). Wait a minimum of 5 minutes for DC bus capacitors to discharge below 50V — verify with a calibrated multimeter at the DC bus terminals before touching internal components.
Step 3 — Board removal: Disconnect all ribbon cables and wiring harnesses from the 1336-BDB-SP5C. Note connector positions with a photo or diagram. Remove the board using ESD-safe handling procedures. Inspect the removed board for burnt traces, failed capacitors, or damaged connectors to confirm root cause.
Step 4 — Install 1336-BDB-SP5C spare: Seat the replacement board firmly. Reconnect all harnesses in the documented sequence. Verify no cables are pinched or misrouted.
Step 5 — Power-up and verification: Restore power. Reload saved parameters if the board did not retain them. Run the drive at low speed (5–10 Hz) under no-load conditions to verify normal operation before returning to production. Check for fault codes and confirm I/O response matches pre-failure behavior.
This workflow typically achieves drive restoration in under 2 hours for a prepared maintenance team, versus 2–5 days waiting for OEM repair service — a critical advantage in continuous process environments.
Spare Parts Support FAQ
Q1: Is the 1336-BDB-SP5C compatible with all 1336 PLUS drive ratings?
The 1336-BDB-SP5C control board is designed for the 1336 PLUS series across standard voltage classes (200V, 400V, 600V). However, compatibility should be verified against the drive’s full catalog number and firmware revision. Contact our technical team with your drive nameplate data for confirmation before ordering.
Q2: What testing is performed before shipment?
Each 1336-BDB-SP5C spare undergoes functional bench testing including power-on self-test, I/O signal verification, and communication port check. Units that fail any test stage are quarantined and not shipped. A test report is available upon request for critical applications.
Q3: How should this board be stored as a long-term spare?
Store in the original anti-static bag inside a sealed carton, in a dry environment (humidity <70% RH, temperature 0–40°C). Avoid storage near strong magnetic fields or high-vibration areas. Inspect annually for any signs of corrosion on connectors. Properly stored, the board maintains full functionality for 5+ years.
Q4: What does the 12-month warranty cover?
The 12-month warranty covers manufacturing defects and functional failure under normal operating conditions. It does not cover damage caused by incorrect installation, overvoltage events, or physical mishandling. Warranty claims are processed with return shipment and replacement dispatch within 5 business days of fault confirmation.
© 2026 SMARTNEXMSK. All rights reserved.
Original Source: https://smartnexmsk.com
Contact: [email protected] | +86 18259474341