Allen-Bradley 1336-QOUT-SP19A Spare for 1336 PLUS Automation: Minimize Downtime with Verified Replacement Parts
Unplanned drive failures in AC variable-frequency drive systems are among the most costly disruptions in industrial automation environments. The Allen-Bradley 1336-QOUT-SP19A transistor output assembly is a critical internal spare for the 1336 PLUS series of AC drives — a platform widely deployed across manufacturing, water treatment, material handling, and process control facilities worldwide. When this output assembly fails, the entire drive becomes inoperable, halting motor control and triggering production downtime that can escalate rapidly in cost.
Sourced as an original Allen-Bradley spare part, the 1336-QOUT-SP19A is designed to restore full drive functionality with direct form-fit-function compatibility. Each unit is inspected and tested prior to shipment, backed by a 12-month warranty, and supported by long-term supply continuity for maintenance teams managing aging 1336 PLUS installations. Whether you are executing a planned overhaul, responding to an emergency fault, or building a strategic spare parts inventory, this assembly provides the reliability and traceability that industrial maintenance demands.
Spare Maintenance Table
| Parameter | Specification / Detail |
|---|---|
| Part Number / SKU | 1336-QOUT-SP19A |
| Brand | Allen-Bradley (Rockwell Automation) |
| Compatible Series | 1336 PLUS AC Drive Series |
| Component Type | Transistor Output Assembly (Spare Board) |
| Function | Gate drive output interface for IGBT/transistor switching stage |
| Mounting | Internal drive assembly — direct board replacement |
| Origin | United States (Allen-Bradley / Rockwell Automation OEM) |
| Compatibility | 1336 PLUS series; verify drive catalog number and firmware revision before installation |
| Application Environment | Industrial automation, motor control centers, variable-frequency drive panels |
| Condition | Original spare — inspected and tested before shipment |
| Warranty | 12 months from date of shipment |
| Maintenance Recommendation | Replace as part of scheduled drive overhaul or upon transistor output fault codes; inspect bus capacitors and gate resistors concurrently |
| Lead Time | In-stock units ship within 1–3 business days; contact for volume availability |
Maintenance Planning for Continuous Operation
When a maintenance or procurement engineer identifies a fault in the transistor output stage of a 1336 PLUS drive, the replacement of the 1336-QOUT-SP19A assembly should be treated as part of a broader drive health assessment — not an isolated swap. Experienced field engineers know that a failed output assembly is frequently a symptom of upstream or downstream stress on related components.
Before or during the replacement of the 1336-QOUT-SP19A, the following components in the same drive cabinet and electrical circuit should be inspected or proactively replaced:
- 1336 PLUS Power Supply Board (e.g., 1336-PB series) — Verify DC bus voltage stability; a degraded power supply can stress the output transistor stage and cause repeat failures.
- DC Bus Capacitor Bank — Capacitor aging is a leading cause of transistor output stress. Measure capacitance and ESR; replace if outside tolerance during the same maintenance window.
- Gate Resistors and Snubber Circuits — Inspect for thermal damage or drift; these protect the IGBT switching stage and should be verified whenever the output assembly is replaced.
- 1336 PLUS Control Board (e.g., 1336-L5E or equivalent) — Check for fault history logs via DriveExplorer or RSLogix; a control board storing repeated output fault codes may indicate a deeper logic or feedback issue.
- Terminal Blocks and Wiring Harnesses — Inspect all power and signal wiring connected to the drive for insulation breakdown, loose crimps, or thermal discoloration, particularly on the motor output terminals (U, V, W).
- Input Line Reactor or EMC Filter — A degraded line reactor can allow voltage transients to reach the drive’s internal circuitry; inspect and test as part of the overhaul.
- Motor Contactor and Overload Relay — Confirm contactor contact condition and overload relay calibration; a welded contactor or mis-set overload can cause abnormal current conditions that damage the output stage.
- PanelView HMI or Remote Operator Station — After drive replacement, verify that the operator interface (PanelView 550, 600, or equivalent) correctly reflects drive status and fault-clear commands via DH+ or DeviceNet communication.
- DeviceNet or DH+ Communication Adapter (e.g., 1336-GM6 or 1336-BDN) — Confirm communication adapter firmware and node addressing are intact after the board swap; a reset drive may require re-parameterization of the network node.
Proactive inspection of these components during the same maintenance window significantly reduces the probability of a repeat failure and maximizes the return on the spare parts investment. For facilities managing multiple 1336 PLUS drives, maintaining a minimum stock of one 1336-QOUT-SP19A assembly per drive cluster is a recognized best practice in industrial spare parts management.
Site Replacement Workflow
The 1336-QOUT-SP19A is designed as a direct replacement for the original transistor output assembly in 1336 PLUS drives. The following workflow is recommended for field replacement to minimize downtime and ensure system compatibility:
- Fault Isolation: Confirm the fault code on the drive display or via the connected HMI. Output transistor faults (e.g., F005, F006, or equivalent output-stage fault codes in the 1336 PLUS fault table) indicate the output assembly as the likely failed component.
- Safe Isolation: De-energize the drive following LOTO (Lockout/Tagout) procedures. Allow the DC bus to fully discharge (minimum 5 minutes after power removal; verify with a calibrated voltmeter before opening the enclosure).
- Documentation: Photograph the existing wiring and board orientation before removal. Record the drive’s parameter settings using DriveExplorer or a parameter backup device if available.
- Board Removal and Replacement: Remove the faulty 1336-QOUT-SP19A assembly following the 1336 PLUS hardware service manual. Install the replacement assembly, ensuring all connectors are fully seated and torqued to specification.
- Compatibility Verification: Confirm the replacement assembly catalog number matches the drive’s hardware revision. Cross-reference the 1336 PLUS spare parts list (Publication 1336-6.5.1) if available.
- Commissioning and Test: Re-energize the drive in a no-load condition first. Clear fault history, restore parameters, and run a motor rotation test at low speed before returning to full production load.
- Documentation Closure: Update the maintenance log with the replacement date, part number, and post-replacement test results. Flag the drive for a follow-up inspection at the next scheduled maintenance interval.
This workflow supports rapid recovery from unplanned outages while maintaining the system integrity and safety standards required in industrial automation environments. The 1336-QOUT-SP19A’s direct OEM compatibility eliminates the risk of parameter re-engineering or mechanical adaptation, making it the preferred choice over generic or third-party alternatives for 1336 PLUS maintenance programs.
Spare Parts Support FAQ
Q1: Is the 1336-QOUT-SP19A compatible with all variants of the 1336 PLUS drive series?
The 1336-QOUT-SP19A is designed for the Allen-Bradley 1336 PLUS AC drive series. Compatibility depends on the specific drive catalog number, horsepower rating, and hardware revision. Before ordering, confirm your drive’s catalog number (found on the drive nameplate) and cross-reference with the 1336 PLUS spare parts documentation (Publication 1336-6.5.1) or contact our technical team with your drive nameplate details for verification.
Q2: What testing is performed before shipment, and what does the 12-month warranty cover?
Each 1336-QOUT-SP19A unit undergoes functional inspection and electrical testing prior to shipment to verify output stage integrity and connector condition. The 12-month warranty covers defects in materials and workmanship under normal operating conditions. It does not cover damage resulting from incorrect installation, overvoltage events, or operation outside the drive’s rated parameters. Warranty claims are supported with return authorization and technical review.
Q3: How should I manage spare parts inventory for a facility with multiple 1336 PLUS drives?
For facilities operating three or more 1336 PLUS drives, maintaining at least one 1336-QOUT-SP19A in on-site spare stock is recommended. Given that the 1336 PLUS platform is a mature product line, lead times for some spare assemblies can extend in the open market. Holding a critical spare eliminates procurement lead time from the downtime equation. For larger fleets, a tiered inventory strategy — with fast-moving consumables (capacitors, fuses, terminal blocks) stocked at higher quantities and board-level spares at one-per-cluster — is a cost-effective approach.
Q4: Can the 1336-QOUT-SP19A be used to replace older or discontinued output assembly variants in legacy 1336 PLUS installations?
In many cases, yes — the 1336-QOUT-SP19A may serve as a direct or functionally equivalent replacement for earlier output assembly revisions within the 1336 PLUS hardware family. However, hardware revision compatibility must be confirmed before installation, as connector pinouts or mounting configurations may differ between early and late production runs. Contact our technical support team with your existing assembly part number and drive catalog number for a compatibility assessment before ordering.
© 2026 SMARTNEXMSK. All rights reserved.
Original Source: https://smartnexmsk.com
Contact: [email protected] | +86 18259474341