Allen-Bradley 1336F-BRF50-AA-EN Retrofit-Ready AC Drive

Allen-Bradley 1336F-BRF50-AA-EN retrofit-ready AC drive for 1336 FORCE systems. 5HP 460V, drop-in replacement, 12-month warranty. Fast shipping.

SKU / Model 1336F-BRF50-AA-EN
Brand Allen-Bradley
Product Type AC Variable Frequency Drive
Country of Origin US
Catalog Category Business & Industrial > Automation, Control & Flow Devices > Industrial Control Systems > Variable Frequency Drives
Model checkSKU and compatibility Quality evidencePhotos on request Export supportPacking and delivery
Description

Allen-Bradley 1336F-BRF50-AA-EN Retrofit-Ready AC Drive Overview

Allen-Bradley 1336F-BRF50-AA-EN Retrofit-Ready AC Drive for 1336 FORCE Control Systems

The Allen-Bradley 1336F-BRF50-AA-EN is a 5HP (3.7 kW), 460V three-phase AC variable frequency drive from the 1336 FORCE series — one of Rockwell Automation’s most widely deployed drive platforms across discrete manufacturing, material handling, pump and fan control, and process automation lines. As the 1336 FORCE series has reached end-of-life status, sourcing a verified, tested replacement unit has become a critical priority for maintenance engineers managing legacy control cabinets. This listing provides a retrofit-ready, fully tested 1336F-BRF50-AA-EN with 12-month warranty coverage and documented compatibility for direct panel replacement.

Whether your facility is executing a planned modernization or responding to an unplanned drive failure, the 1336F-BRF50-AA-EN can be integrated into existing 1336 FORCE installations with minimal engineering intervention — provided the correct pre-installation checks are completed. The sections below outline the compatibility matrix, retrofit planning considerations, downtime control strategy, and common field questions to support your engineering and procurement teams.

Upgrade Compatibility Table

Parameter 1336F-BRF50-AA-EN Specification Retrofit Notes
Power Rating 5HP / 3.7 kW Verify motor nameplate matches; do not upsize without recalculating overload relay settings
Input Voltage 460V AC, 3-Phase, 50/60 Hz Confirm panel supply voltage before installation; mismatch will damage the drive
Output Current 7.6A continuous Check motor FLA; derate if ambient temperature exceeds 40°C
Enclosure / Mounting IP20, panel-mount Existing 1336 FORCE mounting footprint is compatible; verify DIN rail or back-panel bolt pattern
Control Interface Terminal block TB1/TB2 (analog + digital I/O) Re-use existing field wiring; confirm terminal numbering against 1336F wiring diagram
Communication DH-485 / Remote I/O (RIO) via 1336-GM1 or 1336-GM6 option card Verify option card is present and seated; RIO rack address must be re-configured after swap
HMI Compatibility Compatible with PanelView 550/600/900 via DH-485 HMI tag addresses remain valid if drive node address is preserved
Programming Parameter set via 1336-MOD-L10 keypad or DriveExplorer software Back up parameter file from failed unit before removal if drive is still partially functional
Replacement Path Direct 1336 FORCE drop-in; PowerFlex 40/70 as long-term migration target PowerFlex migration requires new wiring harness and PLC program update
Warranty 12 Months Covers manufacturing defects; includes pre-shipment functional test report

Retrofit Planning for Existing Automation Systems

Successful replacement of a 1336F-BRF50-AA-EN in a live production environment requires systematic pre-work across electrical, mechanical, and software domains. Begin by documenting the existing drive’s parameter file using DriveExplorer or the 1336-MOD-L10 hand-held programming terminal. If the failed unit is non-functional, retrieve the last known parameter backup from your maintenance management system or from the PLC program comments — many integrators embed critical drive parameters in RSLogix 500 rung comments for exactly this scenario.

On the electrical side, confirm that the 1336 FORCE power supply feeding the control cabinet — typically a 1336-PB or equivalent 24VDC auxiliary supply — is within specification before energizing the replacement drive. A degraded power supply is a common secondary failure mode that can damage a new drive within hours of commissioning. Similarly, inspect the 1336 FORCE backplane or chassis if the drive is installed in a multi-drive rack configuration; a cracked backplane connector or corroded bus bar can cause intermittent faults that are difficult to diagnose after the drive swap.

Terminal wiring should be transferred wire-by-wire using the original panel drawings. Pay particular attention to the analog reference input (terminals 1–3 on TB2), the enable and run permissive signals (TB1), and the fault relay output wiring. If the original installation used a 1336-GM1 Remote I/O adapter or a 1336-GM6 DeviceNet adapter, confirm that the option card is physically transferred to the replacement unit and that the rack address DIP switches are set identically to the original configuration. The controlling PLC — often a SLC 5/04 or PLC-5/40 — will not recognize the drive on the RIO network if the rack address or starting quarter differs from the original.

For facilities running a mixed drive environment that also includes 1336 IMPACT or 1336 PLUS II drives on the same RIO network, ensure that the replacement 1336F-BRF50-AA-EN does not conflict with existing rack address assignments. Use RSNetWorx or a manual RIO map to verify address space before powering up. If the control system also includes a 1771 I/O chassis or 1746 SLC I/O rack feeding permissive signals to the drive, verify that all interlock logic is intact and that the PLC program’s drive status bits are correctly mapped before issuing a run command.

Where the retrofit is part of a broader control cabinet upgrade that also involves replacing a 1336-BDB bus supply, adding a 1336-MOD-HA2 dynamic braking resistor, or installing a new 1321 line reactor for harmonic mitigation, sequence these tasks before the drive swap to avoid multiple energization cycles on the new unit. Pre-stage all components, complete the mechanical installation, perform insulation resistance testing on the motor cable, and only then apply power for the first commissioning run.

Downtime Control During System Migration

Unplanned drive failures on 1336 FORCE installations typically result in 4–24 hours of downtime depending on spare parts availability and engineering resource response time. Having a pre-tested 1336F-BRF50-AA-EN on the shelf — or sourced from a verified supplier with same-day or next-day dispatch — is the single most effective downtime reduction strategy for legacy 1336 FORCE installations.

For planned maintenance windows, the recommended swap procedure is: (1) back up the drive parameter file, (2) photograph all terminal wiring before disconnection, (3) remove the failed unit and install the replacement, (4) transfer option cards and verify DIP switch settings, (5) reconnect field wiring terminal-by-terminal, (6) restore the parameter file, (7) perform a no-load jog test at low speed before reconnecting the motor, and (8) execute a loaded test run with process engineers present to confirm speed reference tracking and fault relay behavior.

If the original drive parameter file is unavailable, the 1336F-BRF50-AA-EN ships with factory default parameters. The most critical parameters to reconfigure from defaults are: Motor NP Volts (P31), Motor NP Hz (P32), Motor NP FLA (P33), Motor NP RPM (P34), Maximum Frequency (P55), Accel Time 1 (P36), Decel Time 1 (P37), and the Stop Mode (P14). These eight parameters, correctly set, will restore basic drive operation in most standard pump, fan, and conveyor applications. Advanced features such as PID control, flying start, and encoder feedback require additional parameter configuration and should be validated against the original application design documentation.

To protect original PLC program logic during the migration, do not modify any PLC program files during the drive swap. The SLC or PLC-5 program’s drive control and status logic is independent of the physical drive hardware — as long as the RIO rack address and module configuration are preserved, the PLC will resume normal drive control immediately after the network is re-established. This approach eliminates the risk of introducing PLC program errors during what should be a hardware-only maintenance event.

Retrofit Support FAQ

Q1: Is the 1336F-BRF50-AA-EN a direct drop-in replacement for my existing 1336 FORCE drive?
Yes, within the 1336 FORCE product family, the 1336F-BRF50-AA-EN is a direct mechanical and electrical replacement for units of the same power rating and voltage class. The mounting footprint, terminal block layout, and option card slots are identical across the 1336 FORCE series. You must transfer your existing option cards (RIO, DeviceNet, or DH-485 adapters) and restore your parameter file to achieve full functional equivalence.

Q2: What commissioning steps are required after installation?
At minimum: restore the parameter file (or manually re-enter motor nameplate data and application-specific parameters), verify the RIO or DeviceNet node address, perform a no-load jog test, and confirm fault relay wiring. For applications with dynamic braking, PID control, or encoder feedback, additional parameter verification is required. A pre-shipment functional test report is included with each unit to confirm the drive was verified operational before dispatch.

Q3: Can I use this drive if I am migrating from 1336 FORCE to PowerFlex 40 or PowerFlex 70?
The 1336F-BRF50-AA-EN is intended for direct 1336 FORCE replacement, not as a migration bridge to PowerFlex. If your long-term plan is to migrate to PowerFlex 40 or PowerFlex 70, the 1336F-BRF50-AA-EN is the correct interim solution to restore production immediately while the PowerFlex migration is engineered. The PowerFlex migration will require new wiring, a new PLC program block, and HMI screen updates — work that should be planned and tested offline before the cutover.

Q4: What does the 12-month warranty cover, and what is the claims process?
The 12-month warranty covers manufacturing defects and component failures under normal operating conditions. Each unit undergoes a pre-shipment functional test. If a warranty claim is required, contact [email protected] with the order number, a description of the fault, and any available fault code data. Warranty units are processed with priority dispatch to minimize your production downtime.


© 2026 SMARTNEXMSK. All rights reserved.
Original Source: https://smartnexmsk.com
Contact: [email protected] | +86 18259474341

Catalog Paths

Continue from this exact model

Use the live catalog paths below to compare the same brand, product type, or series before sending your RFQ.

RFQ Intent Desk

Choose the right sourcing path for this model

Each action carries the product model and intent into the inquiry record so the sales follow-up starts with useful context.

Exact Model Quote

Use this path when the SKU, brand, quantity, and destination are already confirmed.

Start
Replacement Check

Use this path for old, obsolete, or uncertain models that need compatibility review.

Start
Quality Confirmation

Ask for label photos, packing notes, documentation, or pre-shipment checks.

Start