Allen-Bradley 1783-BMS20CA Retrofit Switch for Stratix 5700 Control Systems
The Allen-Bradley 1783-BMS20CA is a 20-port managed Ethernet switch from the Stratix 5700 series, engineered for industrial automation environments where network reliability, deterministic communication, and seamless integration with Rockwell Automation control platforms are non-negotiable. As legacy Stratix 5700 units reach end-of-life or become unavailable through standard distribution channels, the 1783-BMS20CA remains a critical retrofit and replacement component for facilities running EtherNet/IP-based control architectures across manufacturing, oil & gas, water treatment, and discrete assembly lines.
When planning a retrofit or upgrade around the 1783-BMS20CA, engineers must verify several key parameters before installation: available power budget on the control cabinet rail, terminal block wiring compatibility with existing Cat5e/Cat6 field cabling, backplane interface alignment with the host rack or DIN-rail mounting configuration, module addressing within the EtherNet/IP network topology, and program logic compatibility within the Studio 5000 Logix Designer environment. HMI screen updates in FactoryTalk View SE or ME may also be required if IP address assignments change during the migration. Communication link integrity between the switch and upstream devices — such as a 1756-EN2T or 1756-EN3TR EtherNet/IP communication module in a ControlLogix rack — must be validated prior to returning the line to production.
Upgrade Compatibility Table
| Parameter | Details |
|---|---|
| SKU / Part Number | 1783-BMS20CA |
| Series | Stratix 5700 |
| Port Count | 20 Ports (16 copper + 4 combo SFP) |
| Communication Protocol | EtherNet/IP, IEEE 802.3, IGMP Snooping, RSTP |
| Mounting | DIN-rail / Panel mount |
| Power Supply Compatibility | 24 VDC nominal; verify cabinet PSU capacity before swap |
| Common Replacement Targets | 1783-BMS10CA, 1783-BMS10CGA, 1783-BMS20CGA (verify port/SFP requirements) |
| Controller Compatibility | ControlLogix, CompactLogix, GuardLogix via EtherNet/IP |
| Programming Interface | Studio 5000 Logix Designer, Device Manager Web UI |
| HMI Integration | FactoryTalk View SE / ME (IP re-mapping may be required) |
| Commissioning Requirement | IP address assignment, VLAN config, port mirroring verification |
| Warranty | 12-Month Warranty included |
Retrofit Planning for Existing Automation Systems
Integrating the 1783-BMS20CA into an existing control system requires a structured approach to avoid unplanned downtime and configuration drift. In a typical ControlLogix-based cabinet, the switch sits between the 1756-L8x or 1756-L7x controller backplane and the field device network. Before removal of the legacy switch, document all active port assignments, VLAN memberships, and QoS policies using the existing Device Manager configuration export.
Power supply sizing is a common oversight during Stratix 5700 retrofits. The 1783-BMS20CA draws up to 25W under full port load; confirm that the 1606-XLP or equivalent 24 VDC power supply in the cabinet has sufficient headroom after accounting for other rail-mounted devices such as the 1734-AENT POINT I/O adapter, 1756-PA75 power supply module, and any 1783-ETAP Ethernet tap units already on the network segment.
For facilities migrating from older unmanaged switches or from a 1783-EMS series device, the transition to the managed Stratix 5700 platform introduces IGMP snooping and RSTP ring topology support — features that require corresponding configuration in the upstream 1756-EN2T or 1756-EN3TR EtherNet/IP bridge module. Verify that the PLC program’s produced/consumed tag scan rates are compatible with the new network latency profile before going live.
I/O expansion modules connected downstream — including 1734-IB8, 1734-OB8, or 1734-IE4C analog input cards on a POINT I/O rail — should be tested for communication continuity after the switch replacement. If the system uses a 2711P-T10C21D8S PanelView Plus 7 HMI, confirm that the HMI’s Ethernet port is correctly mapped to the new switch port and that FactoryTalk View SE server connections are re-established before operator handover. Programming cables such as the 1784-U2DHP USB-to-DH+ adapter may be needed for legacy device diagnostics during the commissioning phase.
Downtime Control During System Migration
Minimizing production interruption during a Stratix 5700 switch replacement begins with pre-staging. Before the maintenance window opens, pre-configure the replacement 1783-BMS20CA offline using the Device Manager web interface or Cisco IOS CLI — replicating the VLAN structure, port security settings, IGMP querier configuration, and RSTP priority values from the outgoing unit. Export the configuration file from the legacy switch and import it to the new unit where firmware versions permit.
During the cutover window, follow a port-by-port reconnection sequence rather than a bulk cable transfer. This approach allows the EtherNet/IP network to re-establish device connections incrementally, reducing the risk of a broadcast storm or address conflict that could force a full controller fault. Keep the Studio 5000 project open and monitor the I/O tree in RSLogix 5000 or Studio 5000 for any faulted modules as each port comes online.
Original PLC program logic does not need to be modified for a like-for-like 1783-BMS20CA replacement, provided IP addresses and subnet masks are preserved. If the replacement involves a port-count or SFP configuration change — for example, moving from a 1783-BMS10CA to the 20-port 1783-BMS20CA — update the network topology diagram and notify the SCADA or DCS historian (such as a FactoryTalk Historian SE node) of any IP changes to maintain data continuity. Field control continuity is maintained throughout by keeping the controller in Run mode and relying on EtherNet/IP’s connection timeout tolerance during the brief reconnection interval.
Retrofit Support FAQ
Q1: Is the 1783-BMS20CA a direct drop-in replacement for the 1783-BMS10CA?
The 1783-BMS20CA offers 20 ports versus the 10-port 1783-BMS10CA. Physical mounting dimensions and DIN-rail footprint differ; verify cabinet space before ordering. EtherNet/IP protocol compatibility and Stratix 5700 firmware are shared across the series, so controller-side configuration changes are minimal.
Q2: What commissioning steps are required after installation?
Assign the correct IP address via BOOTP/DHCP or static configuration, restore the saved Device Manager configuration file, verify VLAN and RSTP settings, confirm IGMP snooping is active for multicast I/O traffic, and perform a full I/O communication check from the Studio 5000 controller tree before releasing the line.
Q3: Will my existing field wiring and terminal blocks work with the 1783-BMS20CA?
The 1783-BMS20CA uses standard RJ-45 copper ports and SFP combo slots. Existing Cat5e or Cat6 patch cables and field wiring terminate directly without adapter hardware. For fiber uplinks, confirm SFP transceiver type (multimode vs. single-mode) matches the installed fiber infrastructure.
Q4: What does the 12-month warranty cover?
All units supplied by SMARTNEXMSK carry a 12-month warranty covering manufacturing defects and functional failures under normal operating conditions. Each unit undergoes pre-shipment functional testing including port communication verification and power-on diagnostics. Warranty claims are processed via [email protected] with a typical response within one business day.