Allen-Bradley 80190-380-01-R Retrofit-Ready Rectifier Board for SCB Series Control Systems
The Allen-Bradley 80190-380-01-R is a rectifier board designed for seamless compatibility with the SCB (Signal Conditioning Board) architecture used across the 1336 PLUS, 1336 IMPACT, and 1336 FORCE AC drive families. As legacy 1336-series drives approach end-of-life and original spare parts become increasingly scarce, the 80190-380-01-R serves as a critical retrofit component for facilities seeking to extend the operational life of existing control cabinets without committing to a full drive replacement. This board is engineered to restore rectifier-stage functionality, stabilize DC bus voltage, and maintain drive integrity in demanding industrial environments including automotive assembly, material handling, pump and fan control, and process manufacturing.
For engineers managing aging automation infrastructure, sourcing a verified replacement for the 80190-380-01-R is often the difference between a controlled maintenance window and an unplanned production shutdown. SMARTNEXMSK maintains ready stock of this board and subjects each unit to functional pre-shipment testing, ensuring that the replacement arrives ready for installation with minimal commissioning time on-site.
Upgrade Compatibility Table
| Parameter | Details |
|---|---|
| SKU / Part Number | 80190-380-01-R |
| Brand | Allen-Bradley (Rockwell Automation) |
| Compatible Drive Series | 1336 PLUS, 1336 PLUS II, 1336 IMPACT, 1336 FORCE |
| Board Function | Rectifier / DC Bus Power Stage |
| Mounting Interface | Direct backplane mount; matches OEM footprint |
| Communication Compatibility | Compatible with DH+, Remote I/O (RIO), DeviceNet adapter configurations on host drive |
| Power Supply Requirement | Verify host drive input voltage (200–240 V or 380–480 V AC) before installation |
| Terminal / Connector Interface | OEM-matched connector pinout; no rewiring required for direct swap |
| Replacement Recommendation | Direct drop-in for failed or degraded OEM 80190-380-01-R boards |
| Commissioning Notes | Verify DC bus capacitor condition; reset drive parameters after board swap |
| Warranty | 12-Month Warranty — covers manufacturing defects and functional failure |
| Pre-Shipment Testing | Yes — functional verification performed before dispatch |
| Origin | USA (Allen-Bradley / Rockwell Automation) |
Retrofit Planning for Existing Automation Systems
When planning a retrofit around the 80190-380-01-R, the scope of work typically extends beyond the board itself. A thorough upgrade assessment should account for the condition of the 1336 PLUS drive chassis, the integrity of the 1336-MOD-HC2 or 1336-MOD-HC4 option modules, and the status of any installed 1336-GM1 or 1336-GM6 communication adapters that bridge the drive to a ControlLogix or SLC 500 controller via Remote I/O or DH+ protocol.
In many retrofit scenarios, the 80190-380-01-R board failure is symptomatic of broader DC bus stress, often linked to aging 1336-series DC bus capacitor banks or a degraded 1336-BRF brake resistor assembly. Before ordering a replacement board, technicians should measure DC bus voltage ripple and inspect the gate driver signals on the IGBT power module. If the 1336 PLUS drive also uses a 1336-L6 or 1336-L11 line filter, verify that the filter has not developed insulation breakdown that could stress the new rectifier board.
For facilities running a mixed control architecture — for example, a PanelView 550 or PanelView 900 HMI communicating over DH+ to a SLC 5/04 or SLC 5/05 processor, which in turn controls multiple 1336 PLUS drives via Remote I/O — the rectifier board replacement must be coordinated with a review of the RIO scanner configuration. The 1747-SN Remote I/O Scanner or 1747-ASB Adapter module settings should be verified to ensure that the drive’s node address and baud rate remain consistent after the board swap and drive power cycle.
Where the retrofit involves migrating from a legacy SLC 500 platform to a ControlLogix 5580 or CompactLogix 5380 controller, the 80190-380-01-R replacement may be part of a phased upgrade strategy. In this context, the drive itself may eventually be replaced by a PowerFlex 525 or PowerFlex 755 AC drive, but the immediate priority is restoring production continuity using the existing 1336 PLUS hardware. The 80190-380-01-R enables this bridge strategy, keeping the legacy drive operational while the broader migration is planned and budgeted.
Terminal block wiring should be documented before removal of the failed board. Pay particular attention to the TB1 and TB2 terminal assignments on the 1336 PLUS control board, and confirm that the 1336-MOD-F2 or 1336-MOD-F4 feedback option module connections are re-seated correctly after the rectifier board is installed. If the control cabinet also houses a 1336-PB power board or a 1336-DB dynamic braking module, inspect these components for signs of thermal stress before returning the drive to service.
Downtime Control During System Migration
Minimizing downtime during a 1336-series rectifier board replacement requires a structured pre-maintenance protocol. Before de-energizing the drive, use RSLogix 500 or RSLogix 5000 to upload and save the current drive parameter file. The 1336 PLUS stores tuning data, speed references, accel/decel ramps, and fault history in non-volatile memory, but a parameter backup ensures that commissioning after the board swap is reduced to verification rather than re-tuning from scratch.
Once the 80190-380-01-R is installed, the recommended commissioning sequence begins with a megger test of the motor leads to confirm insulation integrity, followed by a no-load power-up to verify DC bus voltage and check for fault codes on the 1336 PLUS operator interface or the connected PanelView HMI. If the drive communicates via DeviceNet using a 1336-GM1 adapter, verify that the EDS file and node commissioning in RSNetWorx for DeviceNet remain intact after the power cycle.
For facilities with redundant drive configurations or bypass contactors, the switchover to the bypass circuit during the maintenance window protects production continuity. Document the time required for the board swap — typically 45 to 90 minutes for a trained technician — and schedule the work during a planned maintenance interval or shift changeover to minimize impact on production throughput. SMARTNEXMSK’s pre-tested replacement boards are designed to reduce on-site commissioning time by eliminating the need for incoming inspection and bench testing at the customer’s facility.
Retrofit Support FAQ
Q1: Is the 80190-380-01-R a direct replacement for the original Allen-Bradley board in my 1336 PLUS drive?
Yes. The 80190-380-01-R is a direct form-fit-function replacement for the OEM rectifier board used in 1336 PLUS, 1336 PLUS II, 1336 IMPACT, and 1336 FORCE drives. No mechanical modifications or wiring changes are required for a standard swap. Confirm your drive’s input voltage rating before installation to ensure compatibility with your specific drive variant.
Q2: What pre-shipment testing does SMARTNEXMSK perform on the 80190-380-01-R?
Each unit undergoes functional verification testing prior to dispatch, including power-stage continuity checks and rectifier output validation. The board is shipped with a 12-month warranty covering manufacturing defects and functional failure. If the unit does not perform as expected upon installation, our technical support team will assist with diagnosis and replacement under warranty.
Q3: Do I need to re-tune my 1336 PLUS drive parameters after replacing the rectifier board?
In most cases, drive parameters stored in the 1336 PLUS non-volatile memory are preserved through a board swap, provided the control board and memory module are not disturbed. However, it is strongly recommended to perform a parameter upload using RSLogix 500 before the replacement and to verify all critical parameters — including motor nameplate data, speed references, and PID settings — after the drive is returned to service. A no-load test run should be completed before reconnecting the load.
Q4: Can I use the 80190-380-01-R as an interim solution while planning a full drive upgrade to PowerFlex 755?
Yes. This is one of the most common retrofit strategies for facilities managing aging 1336-series infrastructure. The 80190-380-01-R restores full drive functionality at a fraction of the cost of a new drive, providing a controlled window to plan, budget, and execute a full migration to a PowerFlex 525 or PowerFlex 755 platform. SMARTNEXMSK can advise on both the immediate replacement and the longer-term migration path.
© 2026 SMARTNEXMSK. All rights reserved.
Original Source: https://smartnexmsk.com
Contact: [email protected] | +86 18259474341